Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
Subdivision 3401 - General
CHAPTER 13-196 EXISTING BUILDINGS - MINIMUM REQUIREMENTS
13-196-010 Application.
13-196-020 Occupancy.
13-196-030 Structural stability.
13-196-031 Maintenance of exterior walls and enclosures - Definitions.
13-196-032 Maintenance of exterior walls and enclosures - Application.
13-196-033 Maintenance of exterior walls and enclosures - Critical examinations.
13-196-034 Maintenance of exterior walls and enclosures - Ongoing inspection and repair program.
13-196-035 Maintenance of exterior walls and enclosures - Reporting.
13-196-036 Maintenance of exterior walls - Retention of records at the building.
13-196-036.5 Reserved.
13-196-037 Maintenance of exterior walls and enclosures - Unsafe exterior walls and enclosures.
13-196-038 Rules and regulations.
13-196-038.5 Reserved.
13-196-039 Fines and penalties.
13-196-040 Floor loading.
13-196-050 Exit requirements.
13-196-060 Exits - Generally.
13-196-070 Exits - Types.
13-196-080 Passageways and exits to be unobstructed.
13-196-084 Stairwell re-entry in existing buildings.
13-196-085 Stairwell identification.
13-196-086 Area of rescue assistance identification.
13-196-090 Exit, stairway, fire escape and directional signs.
13-196-100 Smoke alarms - Where required.
13-196-110 Smoke alarms - Installation near sleeping rooms and in living levels.
13-196-120 Smoke alarms - Interior stairwell installation.
13-196-130 Smoke alarms - Standards.
13-196-140 Smoke alarms - Owner/tenant responsibilities.
13-196-150 Smoke alarms - Unlawful acts.
13-196-160 Reserved.
13-196-165 Carbon monoxide detectors.
13-196-170 Self-closing devices required for corridor doors.
13-196-180 Sprinkler systems - Where required.
13-196-190 Standpipe systems - Where required.
13-196-200 Standard fire alarm system requirements.
13-196-203 Life safety data sheet - Required.
13-196-204 Voice communication systems in existing buildings.
13-196-205 Automatic sprinkler system installation in existing high-rise buildings.
13-196-206 Life safety evaluation of existing high- rise buildings.
13-196-207 Materials and installation standards for retrofit fire protection systems.
13-196-208 Smokeproof towers in existing high- rise buildings - Fire shields.
13-196-209 High-rise buildings - Stairways - Doors - Frames.
13-196-210 High rise fire systems - Hotels.
13-196-220 Class II standard fire alarm systems.
13-196-230 Floor area and height.
13-196-240 Automatic fire detectors - Where required.
13-196-250 Permitted omission of sprinklers, heat and smoke detectors.
13-196-260 Fire extinguishers.
13-196-270 Elevator recall.
13-196-271 Continued operation.
13-196-280 Reserved.
13-196-290 Pre-ordinance hotels.
13-196-300 Institutional units.
13-196-310 Roominghouses.
13-196-320 Roominghouses - Sanitary facilities.
13-196-330 Roominghouses - Responsibility of operator.
13-196-340 Minimum requirements for residential buildings - General.
13-196-350 Residential buildings - Water closet.
13-196-360 Residential buildings - Lavatory.
13-196-370 Residential buildings - Bathtub or shower.
13-196-380 Residential buildings - Limitations on sharing sanitary facilities.
13-196-390 Residential buildings - Kitchen sink.
13-196-400 Residential buildings - Heating facilities.
13-196-410 Residential buildings - Heat to be furnished.
13-196-420 Residential buildings - Cold and hot water lines.
13-196-430 Residential buildings - Hot water to be furnished.
13-196-440 Gas-fired appliances.
13-196-450 Residential buildings - Hall and stairway lighting.
13-196-460 Residential buildings - Storage beneath stairways.
13-196-470 Residential buildings - Space, use and location - Applicability of provisions.
13-196-480 Residential buildings - Space requirements.
13-196-490 Residential buildings - Space requirements - Sleeping rooms.
13-196-500 Residential buildings - Access to water closets.
13-196-510 Residential buildings - Ceiling heights.
13-196-520 Residential buildings - Basement units.
13-196-530 Residential buildings - Foundations, exterior walls and roofs - Maintenance.
13-196-540 Residential buildings - Floors, interior walls and ceilings - Maintenance.
13-196-550 Residential buildings - Windows, doors and hatchways - Maintenance.
13-196-560 Residential buildings - Screens.
13-196-570 Residential buildings - Stairways and porches - Maintenance.
13-196-580 Residential buildings - Basements and cellars - Maintenance.
13-196-590 Residential buildings - Facilities, equipment, chimneys - Maintenance.
13-196-600 Residential buildings - Lot grading and drainage.
13-196-610 Residential buildings - Responsibilities of owners and occupants - General.
13-196-620 Residential buildings - Responsibilities of occupants.
13-196-630 Residential buildings - Responsibilities of owner or operator.
13-196-640 Residential buildings - Liability to city.
13-196-641 Application of certain sections.
13-196-650 Pre-ordinance conversion to existing buildings - Applicability.
13-196-660 Conversion of pre-ordinance buildings - Height limits.
13-196-670 Stairwells.
13-196-680 Corridors.
13-196-690 Dwelling separations.
13-196-700 Partitions.
13-196-710 Basement ceiling construction.
13-196-720 Heating plants.
13-196-730 Light and ventilation.
13-196-740 One additional dwelling unit over original allowed - Conditions.
13-196-750 Heat required.
13-196-760 Endangering health of employees.
Subdivision 3403 - Additions, Alterations or Repairs
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
13-196-271  Continued operation.
   In buildings equipped with passenger elevators, not less than one passenger elevator shall be maintained in operation at all times when the building is occupied.
   Exception: Buildings equipped with only one passenger elevator shall be permitted to have the elevator temporarily out of service for testing or servicing.
(Added Coun. J. 3-28-18, p. 74459, Art. II, § 20)
13-196-280  Reserved.
Editor's note – Coun. J. 1-10-01, p. 50236, § 1, repealed § 13-196-280, which pertained to elevator safety device test.
13-196-290  Pre-ordinance hotels.
   Every pre-ordinance hotel (built before July 7, 1957) more than two stories and basement in height, having sleeping accommodations for more than 25 persons above the second story, and every pre-ordinance hotel of any capacity more than four stories and basement in height, shall comply with the requirements of Section 15-8-120 pertaining to the protection of stairs, shafts and vertical openings, except as follows:
   (a)   Enclosing walls and partitions may be of construction providing fire resistance of not less than one hour.
   (b)   Doors required for protection of openings in enclosures may be Class C fire doors of combustible material faced on both sides with materials not less fire resistive than sheet steel 18 gauge in thickness. Openings, if any, shall be glazed with wire glass and shall not exceed 144 square inches in area, except that existing openings not exceeding 1,296 square inches in area may be permitted.
   (c)   Where the top or bottom riser in a stairwell is so located that the vertical enclosures therein required will not be practical to erect without unreasonable hardship, a horizontal cutoff there shall be not more than three openings to dwelling units or other nonpublic spaces on each floor, and such dwelling units or nonpublic spaces shall be separated from the corridor by partitions providing fire resistance of not less than one hour with all openings protected with self-closing Class C fire doors.
(Prior code § 78-27)
13-196-300  Institutional units.
   In every pre-ordinance institutional building, every room used for the storage or application of anesthetics consisting of flammable or explosive gases or mixtures, including cyclopropane, ether chloride, ethylene, propylene, or any flammable liquids, shall have safeguards for installation and operation of such rooms and equipment as follows:
   (a)   Any cylinders containing anaesthetizing gases or liquids shall be plainly marked with the name of the substance which they contain and shall comply with the requirements of the Interstate Commerce Commission for such containers. Such cylinders or containers shall not be stored in any operating room. Approved regulators or gas flow devices shall be provided for any such substances, except low pressure oxygen containers.
      No such regulators or gas flow devices shall permit the intermixing of gases by any error or manipulation.
   (b)   The construction and equipment of operating rooms shall comply with the applicable requirements of Section 13-80-040.
(Prior code § 78-28)
13-196-310  Roominghouses.
   Every roominghouse and every rooming unit shall be in compliance with the minimum standards set forth in this chapter, except as modified in Section 13-196-320.
(Prior code § 78-29)
13-196-320  Roominghouses – Sanitary facilities.
   At least one flush water closet, lavatory basin and bathtub or shower shall be supplied for each ten persons or fraction of ten within a roominghouse, including members of the family of the owner if they share the use of the facilities.
   All such facilities shall be properly connected to required water and sewage systems and shall be located within the dwelling so as to be reasonably accessible from a common hall or passageway to all persons sharing such facilities, and shall not be more than one story removed from the rooming unit of any occupant intended to share the facilities. In a roominghouse in which rooms are let only to males, flush urinals may be substituted for not more than 33 and one-third percent of the required number of water closets.
   In a roominghouse where both sexes are accommodated, the water closets shall be separately calculated, based on the occupancy of each sex, except where not more than two water closets are required.
(Prior code § 78-30)
13-196-330  Roominghouses – Responsibility of operator.
   Every operator of a roominghouse shall be responsible for the following matters required by this chapter: extermination of insects, rodents, or other pests in it or in its yard; disposal of refuse by placing in it disposal facilities supplied by him; hanging and removing all screens required; sanitary maintenance of all walls, floors and ceilings; maintenance of a sanitary condition in every part of the roominghouse; and proper installation and repair of every facility.
(Prior code § 78-31)
Loading...