The requirements of this Code relating to size and location of rooms in an industrial or storage unit, shall apply to a hazardous use unit in accordance with the provisions of Section 13-112-110 except as otherwise provided by Chapters 15-24, 15-26 and 15-28 of this Code.
(Prior code § 60-12; Amend Coun. J. 6-14-95, p. 2841; Amend Coun. J. 11-9-16, p. 36266, § 24)
None of the following herein described hazardous use units:
Asphalt, tar, pitch, resin or paraffin heating room;
Corrosive liquid storage room;
Dip tanks having a capacity or liquid surface area in excess of the following:
Capacity | Liquid Surface Area | |
Class I | 10 gallons | 4 square feet |
Class II | 60 gallons | 10 square feet |
Class III | 125 gallons | 15 square feet |
Drying room for any article or material which will give off explosive or flammable vapors during the drying process;
Flammable liquids storage (except as provided in Section 15-24-270 of this Code);
Fume or flammable compressed gas;
Grinding or dust producing;
Hazardous chemical;
Highly flammable material storage;
Highly toxic materials;
Japanning or enameling;
Nitrocellulose products;
Paint spraying or mixing except for water base paint;
Picker or shredder;
Standard fireproof vault;
Sulphur storage;
shall be located in any story below grade in any building hereafter designed, erected, altered or converted for any purpose; provided, however, that one or more rooms built for no purpose other than that of the operation of water purification plants or a refrigerating unit may be located in any basement of any building.
(Prior code § 60-14)
Every court which is necessary in order to obtain windows or other openings for required natural lighting and natural ventilation shall be made to conform with the provisions of this Code for such court in an industrial or storage unit, except as otherwise provided in this chapter.
(Prior code § 60-16)
(Prior code § 60-17; Amend Coun. J. 6-14-95, p. 2841; Amend Coun. J. 11-9-16, p. 36266, § 24)
Every interior doorway from any room or part of a hazardous use air unit, which is required to have an enclosure of one hour fire resistive or more fire resistive construction, shall have a fire door as provided by Chapter 15-12 for such an enclosure, except as provided in Chapters 15-24, 15-26 and 15-28.
(Prior code § 60-18; Amend Coun. J. 6-14-95, p. 2841; Amend Coun. J. 11-9-16, p. 36266, § 24)