The sign standards set forth in this section are intended to apply to signs in every zoning district in the City. Only signs authorized by this section within a particular zoning district shall be allowed in that zoning district unless otherwise expressly provided in this chapter. Signs permitted in the PQ (Public/Quasi Public Facilities) zoning district shall be subject to the Community Development Director's determination based on comparable sign installations for similar uses, the use of the site, and surrounding zoning districts.
(Ord. 2443; Ord. 2564 §3)
Note: To view Table 5-8 in PDF, please click TABLE 5-8
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Single-family and duplex identification | Name plate or street address | 1 per dwelling or occupant | 1 s.f. | Below edge of roof | Wall, fence, or mailbox | No | |
Multi-family and dormitory identification | Wall or monument | 1 per street frontage | 24 s.f. max. | Below edge of roof; 6 ft. monument | 10 ft. minimum front setback, 5 ft. side setback | Indirect only | |
Group care homes, bed and breakfast inns, boarding/ rooming houses, fraternity/ sorority houses | Wall or monument | 1 per street frontage | 12 s.f. max. | Below edge of roof; 6 ft. monument | 10 ft. minimum front setback, 5 ft. side setback | Indirect only | |
Child care facilities | Wall or monument | 1 per street frontage | 6 s.f. max. | Below edge of roof; 6 ft. monument | 10 ft. minimum front setback, 5 ft. side setback | No | |
Religious, educational, governmental, recreational | Wall, projecting & directory | Director or entitlement approval | Director or entitlement approval | Below edge of roof; 6 ft. monument | 10 ft. minimum front setback, 5 ft. side setback | Indirect only | |
Mobile home park | Wall or monument | 1 per access drive | 24 s.f. max. | 8 ft. wall or 6 ft. monument | 10 ft. minimum front setback, 5 ft. side setback | Indirect only | |
Home occupation | Name plate | 1 per dwelling | 1 s.f. | Below edge of roof | Wall, fence, or mailbox | No | |
B. Signs Permitted in the RMU (Residential Mixed Use) Zoning District (Residential uses in the RMU District shall comply with Table 5-8(A) Signs Permitted in the Residential Zoning Districts.)
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Single-tenant sites, not a center 1. Business identification | Wall | 1 each per building frontage | 1 s.f. per linear foot of building frontage, not to exceed 100 s.f. total | Below eave | On building in which the business is located | Indirect only | Wall signs shall consist of individual wall-mounted letters and/or logos. Cabinet-type signs are permitted only with Board approval. |
2. Business identification | Ground | 1 per site | 15 s.f. for one face or 30 s.f. for two or more faces | 5 ft. above adjacent grade | On the private property of the site | Indirect only | The total allowable sign area includes the cumulative area of wall, ground, awning, projecting, and permanent window signs. |
3. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window | Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Indirect only | Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right-of-way in conformance with the UBC. |
4. Business identification | Window (1) | Based on total sign area | 10% of window area or 16 s.f., whichever is less | First and second floor windows only | Permanently painted or mounted on interior of windows located on ground floor or second story of a building frontage | Indirect or neon signs | |
5. Business identification | Awning | Based on total sign area | 10% of awning surface or 25 s.f. total, whichever is less | N/A | On building frontages, including those fronting a parking lot or pedestrian way; limited to ground-level and second-story occupancies. | Indirect only (see Section 19.74.120). Awnings shall not be internally illuminated. | May project over public right-of-way in conformance with the UBC. Cabinet-type signs may be permitted only with Board approval. |
6. Business identification | Under canopy or marquee (“Blade Sign”) | 1 per business frontage (double face) | 4 s.f. per face | N/A | Beneath canopy or marquee with min. 7.5 ft. clearance below sign. | No | May be in addition to window, awning, and wall signs and is not calculated in the total allowable sign area. May project over public right-of-way in conformance with the UBC. |
Multi-tenant sites 1. Business identification | Wall | Based on total sign area | 1 s.f. per linear foot of building frontage on ground floor, 0.5 s.f. per linear foot on second floor, not to exceed 250 s.f. total | Below eave | On building or suite in which the business is located | Indirect only | Wall signs shall consist of individual wall-mounted letters and/or logos. Cabinet-type signs may be permitted only with Board approval. |
2. Business identification | Ground | 1 per site | 15 s.f. for one face or 30 s.f. for two or more faces | 5 feet above adjacent grade | On the private property of the site | Indirect only | |
3. Business identification | Window | Based on total sign area | 15% of first floor window area and 10% of second floor window area, including permanent and temporary signs | N/A | Permanently painted or mounted on interior of windows located on the ground floor or second story of a building frontage. | Indirect or neon | Temporary window signs not permitted above ground floor. |
4. Business identification | Awning | Based on total sign area | 10% of awning surface | N/A | On building frontages, including those fronting a parking lot or pedestrian way; limited to ground-level and second-story occupancies | Indirect only (see Section 19.74.120). Awnings shall not be internally illuminated. | Awning signs not permitted above the second story. |
5. Business identification | Under canopy or marquee (“Blade Sign”) | 1 per business frontage (double face) | 4 s.f. per face | N/A | Beneath canopy or marquee with min. 7.5 ft. clearance below sign. | No | May be in addition to window, awning, projecting, and wall signs and is not calculated in total allowable sign area. May project over public right-of-way. |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Single-tenant sites, not a center 1. Business identification | Wall and/or monument | 1 each per building frontage | 0.75 s.f. of sign area per linear foot of building frontage, 30 s.f. max. | Below eave, 5 ft. for monument | Monument signs shall be set back 5 ft. from property lines. | Indirect only | 1. Total allowable sign area includes wall and monument signs. 2. Refer to Section 19.74.120. |
Multi-tenant sites 1. Building or center identification | Wall or monument | 1 per street frontage | 1 s.f. of sign area per linear foot of building frontage. 40 s.f. max. | Below eave, 6 ft. for monument | Monument signs shall be set back 5 ft. from property lines | Indirect only | Refer to Section 19.74.120. |
2. Business identification | Wall or hanging | 1 per tenant | 8 s.f. each | Below eave | Wall or canopy | Indirect only | |
3. Business directory | Wall or ground- mounted | To be determined by the Director | 10 s.f. each | 6 ft. | May not be located in any required setback | Indirect only | To identify tenants and provide directions to individual tenants. |
4. Name plate | Wall | 1 per tenant | 2 s.f. each | Below eave | Adjacent to primary entrance of each tenant | No |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Single-tenant sites, not a center 1. Business identification | Wall and/or monument | 1 each per building frontage | 1 s.f. of sign area per linear foot of building frontage, 40 s.f. max. | Below edge of roof, 8 ft. for monument | Monument signs shall be set back 3 ft. from property lines. | Yes | 1. Total allowable sign area includes wall and monument signs. 2. Refer to Section 19.74.120. |
Multi-tenant sites 1. Building or center identification | Wall or monument | 1 per street frontage | 1 s.f. of sign area per linear foot of building frontage. 50 s.f. max. | Below edge of roof, 6 ft. for monument | Monument signs shall be set back 3 ft. from property lines | Yes | Refer to Section 19.74.120. |
2. Business identification | Wall or hanging | 1 per tenant | 8 s.f. each | Below edge of roof | Wall or canopy | Indirect only | |
3. Business directory | Wall or ground- mounted | To be determined by the Director | 10 s.f. each | 6 ft. | May not be located in any required setback | Yes | To identify tenants and provide directions to individual tenants. |
4. Name plate | Wall | 1 per tenant | 2 s.f. each | Below edge of roof | Adjacent to primary entrance of each tenant | No |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Single-tenant sites, not a center 1. Business identification | Wall | 1 each per building frontage | 1 s.f. of sign area per linear foot of parcel frontage, not to exceed 100 s.f. total. | Below eave | On building in which the business is located | Indirect only, or individual channel letters | Wall signs shall consist of individual wall-mounted letters and/or logos. Cabinet-type signs may be permitted only with Board approval. |
2. Business identification | Ground | 1 per site | 15 s.f. for one face or 30 s.f. for two or more faces | 5 feet above adjacent grade | On the private property of the site | Indirect only | |
3. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window | Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Low lumens, indirect preferred, or individual channel letters | Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right-of-way in conformance with the UBC. |
4. Business identification | Window (1) | Based on total sign area | 10% of window area or 16 s.f., whichever is less | First and second floor windows only | Permanently painted or mounted on interior of windows located on the ground floor or second story of a building frontage | Indirect, LED or neon signs | Temporary window signs may be placed on exterior of window if signs would not be clearly visible when placed inside the structure due to treatment of the window for glare reduction and energy conservation; and signs are constructed and installed in a manner that will withstand inclement weather. |
5. Business identification | Awning | Based on total sign area | 10% of awning surface or 25 s.f. total, whichever is less | N/A | On building frontages, including those fronting a parking lot or pedestrian way; limited to ground-level and second-story occupancies. | Indirect only (see Section 19.74.120). Awnings shall not be internally illuminated. | Total allowable sign area includes wall, awning, projecting and window signs. May project over public right-of-way in conformance with the UBC. Cabinet-type signs may be permitted only with Board approval. |
6. Business identification | Under canopy or marquee (“Blade Sign”) | 1 per business frontage (double face) | 4 s.f. per face | N/A | Beneath canopy or marquee with min. 7.5 ft. clearance below sign. | No | May be in addition to window, awning, projecting, and wall signs and is not calculated in the total allowable sign area. May project over public right-of-way in conformance with the UBC. |
Multi-tenant sites (3) 1. Business identification | Wall | Based on total sign area | Up to the allowable maximum sign area (2) (4) | Below eave | On building in which the business is located | Indirect only, or individual channel letters | Wall signs shall consist of individual wall-mounted letters and/or logos. Cabinet-type signs may be permitted only with Board approval. |
2. Business identification | Ground | 1 per site | 15 s.f. for one face or 30 s.f. for two or more faces | 5 feet above adjacent grade | On the private property of the site | Indirect only | |
3. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window | Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Low lumens, indirect preferred, or individual channel letters | Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right-of-way in conformance with the UBC. |
4. Business identification | Window (1) | Based on total sign area | 15% of first floor window area and 10% of second floor window area, including permanent and temporary signs | N/A | Permanently painted or mounted on interior of windows located on the ground floor or second story of a building frontage. | Indirect or neon | Temporary window signs not permitted above ground floor. |
5. Business identification | Awning | Based on total sign area | 10% of awning surface | N/A | On building frontages, including those fronting a parking lot or pedestrian way; limited to ground-level and second-story occupancies | Indirect only (see Section 19.74.120). Awnings shall not be internally illuminated. | Awning signs not permitted above the second story. |
6. Business identification | Under canopy or marquee (“Blade Sign”) | 1 per business frontage (double face) | 4 s.f. per face | N/A | Beneath canopy or marquee with min. 7.5 ft. clearance below sign. | No | May be in addition to window, awning, and wall signs and is not calculated in total allowable sign area. May project over public right-of-way. |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Single-tenant sites, not a center 1. Business identification | Wall | 1 each per building frontage | 1.5 s.f. per linear foot of parcel frontage, not to exceed 250 s.f. total | Below eave | On building in which the business is located | Low lumens, indirect preferred, or individual channel letters | Wall signs shall consist of individual wall-mounted letters and/or logos. Cabinet-type signs may be permitted only with Board approval. |
2. Business identification | Ground | 1 per site | 15 s.f. for one face or 30 s.f. for two or more faces | 5 ft. above adjacent grade | On the private property of the site | Low lumens, indirect preferred, or individual channel letters | The total allowable sign area includes the cumulative area of wall, ground, awning, projecting, and permanent window signs. |
3. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window | Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Low lumens, indirect preferred, or individual channel letters | Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right-of-way in conformance with the UBC. |
4. Business identification | Window (1) | Based on total sign area | 10% of window area or 16 s.f., whichever is less | First and second floor windows only | Permanently painted or mounted on interior of windows located on ground floor or second story of a building frontage | Indirect, LED or neon signs | |
5. Business identification | Awning | Based on total sign area | 10% of awning surface or 25 s.f. total, whichever is less | N/A | On building frontages, including those fronting a parking lot or pedestrian way; limited to ground-level and second-story occupancies.
|
Indirect only (see Section 19.74.120). Awnings shall not be internally illuminated.
|
May project over public right-of-way in conformance with the UBC. Cabinet-type signs may be permitted only with Board approval. |
6. Business identification
| Under canopy or marquee (“Blade Sign”)
|
1 per business frontage (double face) | 4 s.f. per face | N/A | Beneath canopy or marquee with min. 7.5 ft. clearance below sign. | No
|
May be in addition to window, awning, and wall signs and is not calculated in the total allowable sign area. May project over public right-of-way in conformance with the UBC. |
Multi-tenant sites 1. Business identification | Wall | Based on total sign area of all businesses | 1.5 s.f. per linear foot of parcel frontage on ground floor, 0.5 s.f. per linear foot on second floor, not to exceed 250 s.f. total | Below eave | On building or suite in which the business is located | Low lumens, Indirect preferred, or individual channel letters | Wall signs shall consist of individual wall-mounted letters and/or logos. Cabinet-type signs may be permitted only with Board approval. |
2. Business identification | Ground | 1 per site | 15 s.f. for one face or 30 s.f. for two or more faces | 5 feet above adjacent grade | On the private property of the site | Low lumens, Indirect preferred, or individual channel letters | |
3. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window | Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Low lumens, indirect preferred, or individual channel letters | Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right-of-way in conformance with the UBC. |
4. Business identification | Window (1) | Based on total sign area | 15% of first floor window area and 10% of second floor window area, including permanent and temporary signs | N/A | Permanently painted or mounted on interior of windows located on the ground floor or second story of a building frontage. | Indirect, LED or neon | Temporary window signs not permitted above ground floor. |
5. Business identification | Awning | Based on total sign area | 10% of awning surface | N/A | On building frontages, including those fronting a parking lot or pedestrian way; limited to ground-level and second-story occupancies | Indirect only (see Section 19.74.120). Awnings shall not be internally illuminated. Lighting directed downwards only | Awning signs not permitted above the second story. |
6. Business identification | Under canopy or marquee (“Blade sign”) | 1 per business frontage (double face) | 4 s.f. per face | N/A | Beneath canopy or marquee with min. 7.5 ft. clearance below sign. | No | May be in addition to window, awning, projecting, and wall signs and is not calculated in total allowable sign area. May project over public right-of-way in conformance with the UBC. |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Single-Tenant Sites 1. Business identification | Wall | 1 each per building frontage | 1.5 s.f. of sign area per linear foot of building frontage, 50 s.f. max. | May not project above eave or 20 ft. above grade | May be located on parapet or canopy | Indirect or individual channel letters | Total allowable sign area includes all wall, awning, window and ground-mounted signs. Refer to Section 19.74.120. |
2. Business identification | Window | 15% of window area | Not allowed above second floor | Allowed on interior or exterior of glass window or door | No, except LED or neon signs | Total allowable sign area includes all wall, awning, window signs. | |
3. Business identification | Awning | 10% of awning surface or 25 s.f., whichever is less | No | Total allowable sign area includes all wall, awning, window signs. Refer to Section 19.74.120. | |||
4. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window | Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Low lumens, indirect preferred, or individual channel letters | Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right- of-way in conformance with the UBC. |
5. Business identification | Under canopy or marquee | 1 per business (double face) | 4 s.f. per face | Beneath canopy or marquee with min. 7.5 ft. clearance below sign | No | Signs shall be uniform in color and design for all tenant identification within a center. May be in addition to window, awning, and wall signs. | |
6. Business identification | Monument | 1 per street frontage | 16 s.f. per face | 6 ft. | Indirect only | Refer to Section 19.74.120. | |
For office uses allowed in the CN zoning district, refer to signs permitted in the OC zoning district. For residential uses allowed in the CN zoning district, refer to signs permitted in residential zoning districts. | |||||||
Multi-tenant sites 1. Business identification | Wall | Based on total sign area | 1 s.f. per linear foot of building frontage on ground floor, 0.5 s.f. per linear foot on second floor, not to exceed 250 s.f. total | Below eave | On building or suite in which the business is located | Indirect or individual channel letters | Wall signs shall consist of individual wall-mounted letters and/or logos. Cabinet-type signs may be permitted only with Board approval. |
2. Business identification | Ground | 1 per site | 15 s.f. for one face or 30 s.f. for two or more faces | 5 feet above adjacent grade | On the private property of the site | Indirect only | |
3. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window | Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Low lumens, indirect preferred, or individual channel letters | Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right-of-way in conformance with the UBC. |
4. Business identification | Window | Based on total sign area | 15% of first floor window area and 10% of second floor window area, including permanent and temporary signs | N/A | Permanently painted or mounted on interior of windows located on the ground floor or second story of a building frontage. | Indirect or neon | Temporary window signs not permitted above ground floor. |
5. Business identification | Awning | Based on total sign area | 10% of awning surface | N/A | On building frontages, including those fronting a parking lot or pedestrian way; limited to ground-level and second-story occupancies | Indirect only (see Section 19.74.120). Awnings shall not be internally illuminated. Lighting directed downwards only. | Awning signs not permitted above the second story. |
6. Business identification
|
Under canopy or marquee (“Blade sign”) | 1 per business frontage (double face) | 4 s.f. per face | N/A | Beneath canopy or marquee with min. 7.5 ft. clearance below sign. | No | May be in addition to window, awning, projecting, and wall signs and is not calculated in total allowable sign area. May project over public right-of-way in conformance with the UBC. |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Single-tenant sites, not a center 1. Business identification | Wall Ground- mounted | 2 per street frontage for wall signs 1 per street frontage for ground- mounted. 50 s.f. max. per sign face. | 2 s.f. of sign area/linear ft. of building frontage for ground floor uses. 0.5 s.f. per linear foot of business frontage for uses on second or higher floors. 30 s.f. min. and 500 s.f. max. | Below eave, and 12 ft. for ground- mounted | Sign shall be set back 5 ft. from property lines and shall not block sight distance area | Yes | Total allowable sign area includes wall, ground- mounted, and awning. |
2. Business identification | Window | 33% of window area including permanent and temporary signs | No, except LED and neon signs | Temporary window signs count towards allowable total aggregate sign area. | |||
3. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window | Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Low lumens, indirect preferred, or individual channel letters | Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right-of-way in conformance with the UBC. |
4. Business identification | Awning | 10% of awning surface or 25 s.f. whichever is less | No | Total allowable sign area includes wall, ground- mounted, and awning signs. Refer to Section 19.74.120. | |||
Multi-tenant sites, shopping centers 1. Center identification | Ground-mounted | 1 per street frontage | 100 s.f. per sign face, 200 s.f. minimum and 400 s.f. max. per sign | 20 ft. | Sign shall be set back 5 ft. from property lines and shall not block sight distance area | Yes | Allowable in addition to other signs for individual businesses. |
2. Business identification (detached buildings greater than 10,000 s.f. gross floor area) | Monument | 1 per street frontage if located within 50 ft. of public street | 16 s.f. per sign face, 32 s.f. maximum per sign | 5 ft. | Sign shall be set back 5 ft. from property lines and shall not block sight distance area | Yes | Total allowable sign area includes wall, monument, and awning signs. |
3. Business identification | Wall | 1 per street ftontage and/or per customer public entrance. | 2 s.f. of sign area per linear foot of bldg. frontage for ground floor uses. 0.5 s.f. per linear foot of business frontage for uses on second or higher floors. 32 s.f. minimum and 200 s.f. max. per business. | Below eave | Yes | Total allowable sign area includes wall, monument, and awning signs. Anchor tenants (as defined by this chapter) within a multi-tenant developmet allowed up to 75 percent additional s.f., 350 s.f. maximum per businesss. | |
4. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window
|
Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Low lumens, indirect preferred, or individual channel letters
|
Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right-of-way in conformance with the UBC. |
5. Business identification | Awning | 10% of awning or 25 s.f., whichever is less | No | Total allowable sign area includes wall, ground- mounted, and awning signs. Refer to Section 19.74.120. | |||
6. Business identification | Window | 33% of window area including permanent and temporary signs | No, except LED and neon signs | ||||
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Single-tenant sites, not a center 1. Business identification | Wall Ground-mounted | 2 per street frontage for wall signs 1 per street frontage for ground- mounted. 50 s.f. max. per sign face. | Wall signs, 2 s.f. of sign area/linear ft. of building frontage for ground floor uses. 0.5 s.f. per linear foot of business frontage for uses on second or higher floors. 50 s.f. min. and 850 s.f. max. | Below eave for wall signs 12 ft. for ground- mounted | Sign shall be set back 5 ft. from property lines and shall not block sight distance area | Yes | Total allowable sign area includes wall, ground- mounted, and awning. |
2. Business identification | Window | 33% of window area including permanent and temporary signs | No, except LED and neon signs | Temporary window signs count towards allowable total aggregate sign area.
| |||
3. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window | Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Low lumens, indirect preferred, or individual channel letters | Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right-of-way in conformance with the UBC. |
4. Business identification | Awning | 10% of awning surface or 25 s.f. whichever is less | No | Total allowable sign area includes wall, ground- mounted, and awning signs. Refer to Section 19.74.120.
| |||
Multi-tenant sites, shopping centers 1. Center identification | Ground-mounted | 1 per street frontage | 100 s.f. per sign face, 200 s.f. minimum and 400 s.f. max. per sign | 20 ft. | Sign shall be set back 5 ft. from property lines and shall not block sight distance area | Yes | Allowable in addition to other signs for individual businesses. |
2. Business identification (detached buildings greater than 10,000 s.f. gross floor area) | Monument | 1 per street frontage if located within 50 ft. of public street | 16 s.f. per sign face, 32 s.f. maximum per sign | 5 ft. | Sign shall be set back 5 ft. from property lines and shall not block sight distance area | Yes | Total allowable sign area includes wall, monument, and awning signs. |
3. Business identification | Wall | 1 per street frontage and/or per customer public entrance. | 2 s.f. of sign area per linear foot of bldg. frontage for ground floor uses. 0.5 s.f. per linear foot of business frontage for uses on second or higher floors. 32 s.f. minimum and 200 s.f. max. per business. | Below eave | Yes | Total allowable sign area includes wall, monument, and awning signs. Anchor tenants within a multi-tenant siteare allowed up to 75 percent additional s.f., 350 s.f. maximum per business. | |
4. Business identification | Awning | 10% of awning or 25 s.f., whichever is less | No | Total allowable sign area includes wall, ground- mounted, and awning signs. Refer to Section 19.74.120. | |||
5. Business identification | Projecting Sign | 1 per building frontage | 8 s.f. (4 s.f. per face) | Below eave or below sill of second floor window | Beneath canopy or marquee if present, with min. 7.5 ft. clearance below sign. | Low lumens, indirect preferred, or individual channel letters | Projecting signs in other locations or not meeting standards may be permitted only with Board approval. May project over public right-of-way in conformance with the UBC. |
6. Business identification | Window | 33% of window area including permanent and temporary signs | No, except LED and neon signs | ||||
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Sign Class | Sign Type | Maximum Number | Maximum Sign Area | Maximum Sign Height | Location Requirements | Lighting Allowed? | Additional Requirements |
Single-tenant sites, not a center 1. Business identification | Wall Ground-mounted | 1 ground- mounted sign per street frontage | 2 s.f. of sign area per linear ft. of building frontage, 300 s.f. maximum Ground- mounted - 100 s.f. per face, 200 s.f. max. | Below eave, and 25 ft. for ground- mounted | Signs shall be set back 5 ft. from property lines | Yes | Total allowable sign area includes wall, ground- mounted, and awning signs. |
2. Business identification | Awning | 15% of awning or 25 s.f., whichever is less | No | Total allowable sign area includes wall, ground- mounted, and awning signs. | |||
3. Business identification | Window | 33% of window area including permanent and temporary signs | No, except LED and neon signs | ||||
Multi-tenant sites, shopping centers 1. Center identification | Ground-mounted | 1 per street frontage | 100 s.f. per sign face, 200 s.f. max. | 25 ft. | Signs shall be set back 5 ft. from property lines | Yes | Allowed in addition to other signs for individual businesses. |
2. Business identification | Wall Ground- mounted | 1 ground- mounted sign per street frontage | 2 s.f. of sign area per linear ft. of building frontage, 200 s.f. max per business. Ground- mounted 75 s.f. per face, 150 s.f. max. | Below eave, and 25 ft. for ground- mounted | Signs shall be set back 5 ft. from property lines | Yes | Total allowable sign area includes wall, ground- mounted, and awning signs. |
3. Business identification | Awning | 10% of awning or 25 s.f., whichever is less | No | ||||
4. Business identification | Window (1) | 33% of window area including permanent and temporary signs | No, except LED and neon signs | ||||
Notes:
(1) Signs stating "OPEN" or "CLOSED" which are no larger than 3 s.f. are exempt.
(2) The total allowable sign area includes the cumulative area of wall, awning, and permanent window signs, excluding 1 sign under the canopy or marquee (“blade sign”) which does not exceed 4 s.f. per sign and temporary signs as set forth in Section 19.74.060(C).
(3) For new multi-tenant sites or buildings with 2 or more individual businesses undergoing Board review, a "comprehensive sign program" shall be submitted (Section 19.74.070). Individual permanent window signs may be allowed independent of the comprehensive sign program.
(4) Total maximum sign area is based on 1 s.f. of sign area per linear foot of business frontage on ground floor, not to exceed 200 s.f. total, 0.5 per linear foot of business frontage for uses on second or subsequent floors. Each business is allowed at least 18 s.f. of sign area regardless of actual linear feet of frontage.