Skip to code content (skip section selection)
Compare to:
Chico Overview
Chico, CA Code of Ordinances
CHICO MUNICIPAL CODE
THE CHARTER OF THE CITY OF CHICO
Title 1 GENERAL PROVISIONS
Title 2 ADMINISTRATION AND PERSONNEL
Title 3 REVENUE AND FINANCE
Title 4 (RESERVED)
Title 5 BUSINESS REGULATIONS1
Title 6 (RESERVED)
Title 7 ANIMALS
Title 8 HEALTH AND SANITATION1
Title 9 PUBLIC PEACE, SAFETY AND MORALS
Title 10 VEHICLES AND TRAFFIC
Title 11 AIRPORT1
Title 12 PARKS
Title 13 (RESERVED)
Title 14 STREETS AND SIDEWALKS
Title 15 UTILITY SERVICES
Title 16 BUILDINGS AND CONSTRUCTION1
Chapter 16.02 BUILDING REGULATIONS - GENERAL PROVISIONS
Chapter 16.04 BUILDING REGULATIONS - DEFINITIONS
Chapter 16.06 BUILDING REGULATIONS - BUILDING STANDARDS
Chapter 16.10 BUILDING REGULATIONS - BUILDING PERMITS
Chapter 16.12 BUILDING REGULATIONS - CERTIFICATES OF OCCUPANCY AND CONNECTION APPROVALS
Chapter 16.14 BUILDING REGULATIONS - INSPECTIONS, SURVEYS, AND TESTS
Chapter 16.16 BUILDING REGULATIONS - ENFORCEMENT
Chapter 16.22 GRADING REGULATIONS - GENERAL PROVISIONS
Chapter 16.24 GRADING REGULATIONS - DEFINITIONS
Chapter 16.26 GRADING REGULATIONS - STANDARDS
Chapter 16.28 GRADING REGULATIONS - PERMITS
Chapter 16.30 GRADING REGULATIONS - INSPECTIONS
Chapter 16.32 GRADING REGULATIONS - ENFORCEMENT
Chapter 16.34 FLOODPLAIN REGULATIONS - GENERAL PROVISIONS
Chapter 16.35 FLOODPLAIN REGULATIONS - DEFINITIONS
Chapter 16.36 FLOODPLAIN REGULATIONS - FLOODPLAIN MAPS, RECORDS AND REPORTS
Chapter 16.37 FLOODPLAIN REGULATIONS - STANDARDS
Chapter 16.38 FLOODPLAIN REGULATIONS - ENFORCEMENT
Chapter 16.42 FIRE REGULATIONS - GENERAL PROVISIONS
Chapter 16.44 FIRE REGULATIONS - DEFINITIONS
Chapter 16.46 FIRE REGULATIONS - FIRE REGULATION STANDARDS
Chapter 16.48 FIRE REGULATIONS - PERMITS
Chapter 16.50 FIRE REGULATIONS - INSPECTIONS
Chapter 16.52 FIRE REGULATIONS - ENFORCEMENT
Chapter 16.60 ENERGY CONSERVATION MEASURES REQUIRED INCIDENT TO TRANSFERS OF RESIDENTIAL HOUSING
Chapter 16.62 UNIFORM HOUSING CODE
Chapter 16.64 UNIFORM CODE FOR THE ABATEMENT OF DANGEROUS BUILDINGS
Chapter 16.66 TREE PRESERVATION REGULATIONS
Chapter 16.68 VOLUNTARY HERITAGE TREE PROGRAM
TITLE 16 FOOTNOTES
Title 17 (RESERVED)
Title 18 SUBDIVISIONS
Title 19 LAND USE AND DEVELOPMENT REGULATIONS1
Title 2R ADMINISTRATION AND PERSONNEL AND EMPLOYEE RELATIONS RULES
Title 3R REVENUE AND FINANCE RULES AND PROCEDURES
Title 5R BUSINESS RULES AND REGULATIONS
Title 8R SOLID WASTE COLLECTION RULES
Title 10R VEHICLES AND TRAFFIC RULES AND PROCEDURES
Title 11R CHICO MUNICIPAL AIRPORT RULES AND REGULATIONS1
Title 12R RULES AND REGULATIONS OF BIDWELL PARK AND OTHER PARKS AND PLAYGROUNDS1
Title 14R BUILDING IN STREETS, SIDEWALKS AND PUBLIC PLACES
Title 15R WATER AND SEWERS
Title 16R BUILDING STANDARDS
Title 18R DESIGN CRITERIA AND IMPROVEMENT STANDARDS1
TABLES
Chico, CA Comprehensive Ordinance Table
Chapter 16.14
BUILDING REGULATIONS - INSPECTIONS, SURVEYS, AND TESTS
Section:
16.14.010   General provisions.
16.14.020   Required inspections - Buildings and structures.
16.14.030   Required inspections - Building service equipment.
16.14.040   Required inspections - Signs.
16.14.050   Required inspections - Special inspections.
16.14.060   Required inspections - Other inspections.
16.14.070   Inspection request.
16.14.080   Access to work to be inspected.
16.14.090   Inspection record card.
16.14.100   Notice to county assessor of final inspection.
16.14.110   Inspection fees.
16.14.120   Surveys.
16.14.130   Tests.
16.14.010   General provisions
   All work on a building or structure, building service equipment, or a sign for which a permit is required by Chapter 16.10 of this title shall be subject to the inspections, surveys, and tests required by this chapter, and the right of the building official or other person designated by or pursuant to this chapter to make such inspection, survey or test to enter upon the premises where such work is being performed for the purpose of conducting the inspection, survey, or test shall be a condition of the issuance of such permit. Where an inspection, survey, or test is required at a particular stage of any work for which a permit is required by Chapter 16.10 of this title, the person to whom the permit was issued shall not cause or permit additional work to be performed beyond the state at which such inspection, survey, or test is required until the inspection, survey, or test has been made and the work approved.
(Ord. 1646 §6 (part))
16.14.020   Required inspections - Buildings and structures.
   A.   Inspection by Building Official. The building official shall make the following inspections of all work on a building or structure for which a basic building permit is required by Chapter 16.10 of this title and, following such inspection, shall either approve the work to be inspected as complying with the basic building standards adopted by Chapter 16.06 of this title or shall notify the permit holder or an authorized agent of the reasons why such work fails to comply with same. Where reinforcing steel or structural framework has been constructed in any building or structure to be inspected, the building official shall make such inspection prior to the time such reinforcing steel or structural framework is covered or concealed.
      1.   Foundation Inspection. A foundation inspection shall be made after trenches are excavated and forms erected and when all materials for the foundation are delivered to the work site. Provided that, where concrete from a central mixing plant is to be used, the materials need not be inspected at the work site.
      2.   Concrete Slab or Underfloor Inspection. A concrete slab or underfloor inspection shall be made after all in-slab or underfloor building service equipment, conduit, piping accessories, and other ancillary equipment items are in place, but before any concrete is poured or floor sheeting installed, including the subfloor.
      3.   Frame Inspection. A frame inspection shall be made after the roof, all framing, fireblocking, and bracing are in place; all pipes, chimneys, and vents are complete; and the rough electrical, plumbing, and heating wires, pipes, and ducts are approved.
      4.   Lath or Wallboard Inspection. A lath or wallboard inspection shall be made after all lathing and wallboard, interior or exterior, is in place but before any plastering is applied or before wallboard joints and fasteners are taped and finished.
      5.   Final Inspection. A final inspection shall be made after finish grading on the building is completed and ready for occupancy.
   B.   Inspections by Fire Chief. The fire chief shall make a fire and life safety inspection of all work on a building or structure for which a basic building permit is required by Chapter 16.10 of this title, other than a building or structure classified as a Group R, Division 3 or Group M occupancy by the basic building standards adopted by Chapter 16.06 of this title, when work on such building or structure is complete. Following such inspection, the fire chief shall either approve the work being inspected as complying with the fire and life safety regulations adopted by this code or the laws of this state, or shall notify the permit holder or an authorized agent of the reasons why such building or structure fails to comply with same.
(Ord. 1646 §6 (part), Ord. 2268)
16.14.030   Required inspections - Building service equipment.
   The building official shall make an inspection of all building service equipment for which an electrical permit, mechanical permit, or plumbing permit is required by Chapter 16.10 of this title when the installation of such building service equipment is completed, and shall either approve the building service equipment being inspected as complying with the standards for building service equipment adopted by Chapter 16.06 of this title or shall notify the permit holder or an authorized agent of the reasons why such building service equipment fails to comply with same. When the building service equipment to be inspected will be enclosed by any permanent portion of a building or structure, then the building official shall make an additional inspection of such building service equipment prior to the time it is covered or concealed.
(Ord. 1646 §6 (part), Ord. 2268)
Loading...