19.86.280   Mixed-Use Liner Building
   A.   A building designed for occupancy by retail, service, and/or office uses on the ground floor, with upper floors also for those uses or for dwelling units. The building is designed to shield surface and structured parking from view at the street. A mixed-use liner building shall be placed on a site as set forth in Table 6-27
Table 6-27
Building Placement.
Front build-to-line: The front façade of the building shall be placed at the back of the sidewalk.
A
Encroachment over the sidewalk may be allowed for some frontage types.
B
Side setbacks: None required; 10 feet minimum if provided.
C
Rear setback: 5 feet from the alley.
D
Building Size and Massing.
Building height: Buildings shall be two or three-stories.
E
Parking.
On-site parking shall be located a minimum of 22 feet behind the back of the sidewalk.
F
 
   B.   Groups of liner buildings shall be from three to six attached units, allowing pedestrian access to parking at the block interior.
   C.   Frontage types of shopfronts, galleries, and arcades are preferred.
   D.   The main entrance to each ground floor shopfront shall be directly from the street.
   E.   Entrance to residential portions of the building shall be through a street level lobby, or through a podium lobby accessible from the street or a side yard, or through individual entrances from the street. Where common lobbies are employed, interior access to each dwelling shall be through a corridor.
   F.   On-site parking shall be accessed from an alley and shall be covered or uncovered surface parking.
(Ord. 2358 §22)