Where provisions of Chapter 21 of IBC are adopted by reference, the following terms shall be reset in italic type: "AAC masonry"; "adhered masonry veneer"; "bed joint"; "chimney"; "fireplace"; "fireplace throat"; "fire-resistance rating"; "hollow masonry unit"; "masonry unit"; "mortar"; "solid masonry unit"; "stone masonry"; "structural clay tile"; "surface-bonding mortar" and "wythe."
The provisions of Section 2101 of IBC are adopted by reference with the following modification:
1. Add new Section 2101.2.2 to read:
"2101.2.2 Single-wythe exterior walls.
Masonry units used in single-wythe exterior walls of buildings containing a Group R occupancy shall be tested in accordance with ASTM E514 and shall have integral water repellant included in the manufacturing process.
Exception: Grade SW clay or shale masonry units.
Mortar used in single-wythe exterior walls of buildings containing a Group R occupancy shall have a compatible water repellant added to the mixture."