Two stairways, not less than 30 inches wide from lowest to uppermost level shall be required for each parking structure. These stairways may be of open riser and open grille tread type. There shall be a one-hour fire-resistive wall enclosure separating stairways from parking levels.
(Prior code § 61-20.8)
Protection of openings in exterior walls shall comply with Section 15-8-110.
(Prior code § 61-20.12)
Manlifts shall be designed in accordance with the provisions of the American Standard Safety Code for Manlifts, Publication ASA A90.1-1949, by the American Society of Mechanical Engineers; where slide poles are installed, an interchange shall be required at each parking level, and shall be shielded by wire mesh or railing barriers.