13-96-970  Ramps, hoistways and elevator shafts.
   Ramps, hoistways and elevator shafts used solely for the movement of passenger vehicles from one level to another need not be enclosed.
(Prior code § 61-20.9)
13-96-980  Curbs.
   Adequate approved curbs, not less than 12 inches in height or wheel guards of incombustible construction shall be provided.
(Prior code § 61-20.10)
13-96-990  Railings.
   On every floor where cars are driven, an approved railing or similar device, of incombustible construction shall be provided at every exterior opening where the exterior wall is omitted and at each interior opening in the floor.
(Prior code § 61-20.11)
13-96-1000  Exterior wall opening protection.
   Protection of openings in exterior walls shall comply with Section 15-8-110.
(Prior code § 61-20.12)
13-96-1010  Ceiling height.
   The minimum ceiling height in a parking level shall be not less than seven feet, this to be the minimum clearance measured from the floor to beams, pipes, lighting fixtures or other similar obstructions.
(Prior code § 61-20.13)
13-96-1020  Manlifts.
   Manlifts shall be designed in accordance with the provisions of the American Standard Safety Code for Manlifts, Publication ASA A90.1-1949, by the American Society of Mechanical Engineers; where slide poles are installed, an interchange shall be required at each parking level, and shall be shielded by wire mesh or railing barriers.
(Prior code § 61-20.14)
13-96-1030  Permits.
   The building commissioner and the fire commissioner are authorized and directed to approve plans and to issue permits for the construction of parking facilities described herein when, in their judgment, plans and specifications of said parking facilities conform with the provisions of this ordinance.
(Prior code § 61-20.15; Amend Coun. J. 9-13-89, p. 4604; Amend Coun. J. 3-5-03, p. 104990, § 24; Amend Coun. J. 11-13-07, p. 14999, Art. II, § 1)
ARTICLE XX.  FAMILY FALLOUT SHELTERS (13-96-1040 et seq.)