Chapter 19
ONSITE WASTEWATER TREATMENT SYSTEMS
Sections:
Article 1: Legal Authority
   6-19.101   Legal authority.
Article 2: Purposes
   6-19.201   Purposes.
Article 3: Applicability
   6-19.301   Applicability.
Article 4: Definitions
   6-19.401   Alternative system.
   6-19.402   Appeal.
   6-19.403   Appeal Board.
   6-19.404   Applicant.
   6-19.405   As-built drawing.
   6-19.406   Authorized representative.
   6-19.407   Bedroom or potential sleeping room.
   6-19.408   Beneficial use.
   6-19.409   Building permit.
   6-19.410   Cesspool.
   6-19.411    Cluster system.
   6-19.412   Community system.
   6-19.413   Contamination.
   6-19.414   Contractor.
   6-19.415    Cumulative impacts.
   6-19.416    DEH.
   6-19.417   Director of Environmental Health.
   6-19.418   Dispersal field.
   6-19.419   Dispersal system.
   6-19.420   Division of Environmental Health (DEH).
   6-19.421   Domestic wastewater.
   6-19.422    Effective soil.
   6-19.423   Effluent.
   6-19.424   Expansion.
   6-19.425    Failing system.
   6-19.426    Final approval.
   6-19.427    Geotechnical report.
   6-19.428   Graywater.
   6-19.429    Graywater system.
   6-19.430   Groundwater.
   6-19.431    High strength wastewater.
   6-19.432    Holding tank.
   6-19.433    Industrial wastewater.
   6-19.434   Installation permit.
   6-19.435    Land use project.
   6-19.436    Large system.
   6-19.437    Lot.
   6-19.438   Manual.
   6-19.439   Minimum useable wastewater dispersal area (MUWDA).
   6-19.440    Non-discharging wastewater disposal unit.
   6-19.441    Onsite wastewater treatment system (System).
   6-19.442   Onsite Wastewater Treatment System Manual (Manual).
   6-19.443    Onsite Wastewater Treatment System Policy (OWTS Policy).
   6-19.444    Operating permit.
   6-19.445   Operation, Maintenance and Monitoring (OM&M) Program.
   6-19.446    Owner.
   6-19.447   Percolation test.
   6-19.448    Person.
   6-19.449    Portable toilet.
   6-19.450    Public nuisance.
   6-19.451    Public sewer system.
   6-19.452    Public water system.
   6-19.453    Qualified system designer.
   6-19.454    Qualified professional.
   6-19.455   Regional Water Quality Control Board.
   6-19.456    Replacement area.
   6-19.457    Seepage pit.
   6-19.458    Septage.
   6-19.459    Septage pumper.
   6-19.460    Septic tank.
   6-19.461   Service provider.
   6-19.462    Site evaluation.
   6-19.463    Site evaluation report.
   6-19.464    Site map review.
   6-19.465    Slope.
   6-19.466    Soil.
   6-19.467    Soil texture.
   6-19.468   Standard system.
   6-19.469   Subdivision.
   6-19.470    Substandard tank.
   6-19.471    Supplemental treatment.
   6-19.472    Supplemental treatment unit.
   6-19.473    System.
   6-19.474    System design.
   6-19.475    Unstable land mass.
   6-19.476    Vault privy.
   6-19.477    Vertical separation.
   6-19.478    Wastewater.
   6-19.479    Watercourse.
   6-19.480    Waterless toilet.
Article 5: Onsite Wastewater Treatment System Manual
   6-19.501   Manual.
   6-19.502   Wastewater application rates and septic tank size.
Article 6: General Requirements
   6-19.601   General requirements.
   6-19.602   System subjected to California Central Valley Regional Water Quality Control Board waste discharge requirements.
   6-19.603    Requirements for system contractor.
   6-19.604    Permits.
   6-19.605   Requirements for site evaluation.
   6-19.606    Requirements for siting, design, operation and maintenance.
   6-19.607    Approved sewage disposal required.
   6-19.608    General requirements for building permit application using existing system.
   6-19.609    General requirements for business license application using existing system.
   6-19.610    Prohibitions.
   6-19.611    Minimum horizontal setbacks.
   6-19.612    Minimum vertical setbacks.
   6-19.613    Construction inspections.
   6-19.614    Unauthorized work.
   6-19.615    Abatement.
   6-19.616    Required notification of system failure.
   6-19.617    Required notification of a system installation.
   6-19.618    Abandoned system.
   6-19.619    Refusal to finalize building permit for occupancy.
   6-19.620    Cesspools; seepage pits, and substandard tanks.
   6-19.621    Holding tanks; portable toilets; vault privy.
   6-19.622    Cumulative impacts.
   6-19.623    Property improvements and system expansion.
   6-19.624    Replacement of the dispersal field.
Article 7: Alternative System Requirements
   6-19.701    Use of alternative systems.
   6-19.702    Installation permit and review requirements for alternative systems.
   6-19.703    Operation, maintenance and monitoring (OM&M) requirements.
Article 8: Non-Discharging Wastewater Disposal
   6-19.801
   6-19.802
   6-19.803
   6-19.804
Article 9: Graywater Systems
   6-19.901   Graywater systems.
Article 10: Septage Pumping, Inspections and Reporting Requirements
   6-19.1001    Permitting, inspection and reporting requirements.
Article 11: Land Use Project
   6-19.1101   Land use project.
Article 12: Connection to Public Sewer System
   6-19.1201   Connection to public sewer system required.
Article 13: Groundwater Protection
   6-19.1301   Areas with potential for groundwater pollution.
   6-19.1302    Areas with impacted groundwater.
Article 14: Reporting to Central Valley Regional Water Quality Control Board
   6-19.1401    Report requirements.
   6-19.1402    Records retention.
   6-19.1403    Water Quality Assessment Program.
Article 15: Enforcement and Penalties
   6-19.1501   Enforcement.
   6-19.1502    Right of entry.
   6-19.1503    Notice of violation.
   6-19.1504    Cease and desist orders.
   6-19.1505    Penalties.
Article 16: Appeals
   6-19.1601   Appeals procedure.
Article 17: Severability
   6-19.1701   Severability.