Loading...
Unobstructed walk areas not less than 6 feet (1828 mm) wide shall be provided on at least two sides of the pool; unobstructed walk areas not less than 24 inches (610 mm) wide shall be provided on all sides of the pool. The walk area shall be constructed of impervious material and the surfaces shall be smooth and easily cleaned with a non-slip finish. The slope of the walks shall have a pitch of at least 1/4 inch per foot (6 mm per 300 mm), designed to prevent back drainage from entering the pool. Walk drains shall be provided for each 100 square feet (9.29 m2) of walk area. Drain pipe lines shall be at least 3 inches (75 mm) in diameter, drain openings shall have an open air of at least four times the cross-sectional area of the drain pipe. The walk drain systems shall have an indirect connection to the sewer. The walk drains shall not be connected to the recirculation system piping. The drainage system shall be constructed of materials in conformance with Article 7.
(Added Coun. J. 10-14-21, p. 37722, Art. XII, §1)
Pools shall be completely enclosed by a fence or walls erected along the perimeter of the pool deck. All fence openings or points of entry into the pool enclosure shall be equipped with gates. Fences and gates shall be at least 5 feet (1525 mm) in height above the grade level outside the enclosure and shall meet the requirements for guards in the Chicago Building Code. All gates shall be equipped with self-closing and self-latching devices placed at least 54 inches (1372 mm) above adjacent walking surfaces.
(Added Coun. J. 10-14-21, p. 37722, Art. XII, §1)
The slope of the bottom of any part of the pool in which the water is less than 5 feet (1525 mm) in depth shall not be more than 1 unit vertical in 12 units horizontal (6.67 percent slope). The maximum slope where the water is 5 feet (1525 mm) or more in depth shall not exceed 1 unit vertical in 3 units horizontal (33.3 percent slope).
(Added Coun. J. 10-14-21, p. 37722, Art. XII, §1)
At least two means of egress in the form of steps, ladders or step holes shall be provided from the pool. At least one means of egress shall be located on a side of the pool at both the deep end and shallow end of the pool. Treads of steps, ladders or step holes shall be constructed of non-slip material and shall be at least 3 inches (75 mm) wide for their full length. Steps, ladders and step holes shall be provided with a handrail on both sides.
(Added Coun. J. 10-14-21, p. 37722, Art. XII, §1)
Pools shall be provided with overflow gutters on all vertical walls and shall extend around the entire perimeter of the pool. The overflow gutter shall be of the open, roll over or semi-recessed type, having a smooth finish. The lip or overflow gutter edge shall be level, the overflow gutter shall have a minimum depth of 4 inches (100 mm); the overflow gutter bottom shall have a slope toward each drain and have a pitch not less than 1/4 inch to the foot (6 mm to 300 mm); drain spacings shall be a minimum of 15 feet (4572 mm) on center; drain pipelines shall be at least 3 inches (75 mm) in diameter; outlet fixtures shall have a grate opening of at least twice the cross-sectional area of the drain pipe; the drain lines shall have an indirect connection to the sewer.
(Added Coun. J. 10-14-21, p. 37722, Art. XII, §1)
All water recirculation system inlets and makeup water facilities shall be located, equipped and constructed in accordance with Sections 18-29-1204.4.9.1 through 18-29-1204.4.9.3.
(Added Coun. J. 10-14-21, p. 37722, Art. XII, §1)