18-29-1203.3 Showers, water closets and lavatories.
   Bather preparation facilities shall be provided with at least the number of showers, water closets, urinals and lavatories indicated in Table 18-29-1203.3. Showers and lavatories shall be provided with liquid or powdered soap dispensers. Showers shall be supplied with tempered water or hot water.
Table 18-29-1203.3
Fixtures Required per Bather Load
Bather Load a
Fixtures Required (Male) b
Fixtures Required (Female) b
Water Closets
Urinals
Lavatories
Showers
Water Closets
Lavatories
Showers
Bather Load a
Fixtures Required (Male) b
Fixtures Required (Female) b
Water Closets
Urinals
Lavatories
Showers
Water Closets
Lavatories
Showers
0 - 100
1
0
1
1
1
1
1
101 - 200
1
1
1
2
2
1
2
201 - 300
1
2
2
3
3
2
3
301 - 400
2
2
2
4
4
2
4
401 - 500
2
3
2
5
5
2
5
501 - 1,000
3
3
2
6
6
2
6
1001 - 1,500
4
5
2
10
9
2
10
1,501 - 2,000
5
6
2
15
11
2
15
2,001 or more
6
7
3
20
13
3
20
 
a.   Bather load shall be determined in accordance with Section 1004 of the Chicago Building Code.
b.   Single-user toilet rooms and single-user bathing rooms may be provided in accordance with Section 18-29-403.1.3. In such case, water closets shall be provided instead of required urinals.
(Added Coun. J. 10-14-21, p. 37722, Art. XII, §1)