Article 13. Referenced Standards
NOTE: Add the prefix 18-29- to all cited sections and tables
This article lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section 18-29-102.8.
ANSI | American National Standards Institute 11 West 42nd Street New York, NY 10036 | |
Standard Reference Number | Title | Referenced in code section number |
Z21.22-86 | Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems – with 1990 Addendum | |
Z124.1-95 | Plastic Bathtub Units | |
Z124.2-95 | Plastic Shower Receptors and Shower Stalls | |
Z124.3-95 | Plastic Lavatories | |
Z124.4-86 | Plastic Water Closet Bowls and Tanks | |
Z124.6-90 | Plastic Sinks | |
Z358.1-98 | Emergency Eyewash and Shower Equipment | |
ARI | Air-Conditioning & Refrigeration Institute 4301 N. Fairfax Drive, Suite 425 Arlington, VA 22203 | |
Standard Reference Number | Title | Referenced in code section number |
1010-94 | Self-Contained, Mechanically-Refrigerated Drinking-Water Coolers |
ASME | American Society of Mechanical Engineers 345 East 47th Street New York, NY 10017 | |
Standard Reference Number | Title | Referenced in code section number |
A13.1-81 | Scheme for the Identification of Piping Systems | |
A112.1.2-91 | Air Gaps in Plumbing Systems | Table 608.1 |
A112.6.1-88 | Supports for Off-the-Floor Plumbing Fixtures for Public Use | |
A112.14.1-75 | Backwater Valves | |
A112.18.1M-94 | Brass Plumbing Fixture Units – with 1995 Errata | |
A112.19.1M-94 | Enameled Cast Iron Plumbing Fixtures | |
A112.19.2-95 | Vitreous China Plumbing Fixtures – with 1996 Errata | |
A112.19.3-87 | Stainless Steel Plumbing Fixtures (Designed for Residential Use) | |
A112.19.4M-94 | Porcelain Enameled Formed Steel Plumbing Fixtures | |
A112.19.5-79 | Trim for Water-Closet Bowls, Tanks, and Urinals | |
A112.19.6-95 | Hydraulic Performance Requirements for Water Closets and Urinals | |
A112.19.7-95 | Whirlpool Bathtub Appliances | |
A112.19.8-87 | Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, Hot Tubs, and Whirlpool Bathtub Appliances | |
A112.19.9-91 | Non-Vitreous Ceramic Plumbing Fixtures | |
A112.21.1-91 | Floor Drains | |
A112.21.2-91 | Roof Drains | |
B1.20.1-83 | Pipe Threads, General Purpose (inch) | |
B16.3-92 | Malleable Iron Threaded Fittings | |
B16.4-92 | Cast Iron Threaded Fittings | |
B16.9-93 | Factory-Made Wrought Steel Buttwelding Fittings | |
B16.11-91 | Forged Steel Fittings, Socket-Welding and Threaded | |
B16.12-91 | Cast-Iron Threaded Drainage Fittings | |
B16.15-85 | Cast Bronze Threaded Fittings | |
B16.18-84 | Cast Copper Alloy Solder Joint Pressure Fittings | |
B16.22-95 | Wrought Copper and Copper Alloy Solder Joint Pressure Fittings | |
B16.23-92 | Cast Copper Alloy Solder Joint Drainage Fittings (DWV) – with 1994 Errata | |
B16.26-88 | Cast Copper Alloy Fittings for Flared Copper Tubes | |
B16.28-94 | Wrought Steel Buttwelding Short Radius Elbows and Returns | |
B16.29-94 | Wrought Copper and Wrought Copper Alloy Solder Joint Drainage Fittings – DVW | |
B16.32-92 | Cast Copper Alloy Solder Joint Fittings for Solvent Drainage Systems | |
ASSE | American Society of Sanitary Engineering 28901 Clemens Road Westlake, OH 44145 | |
Standard Reference Number | Title | Referenced in code section number |
1001-90 | Performance Requirements for Pipe Applied Atmospheric Type Vacuum Breakers | |
1002-86 | Performance Requirements for Water Closet Flush Tank Ball Cocks | |
1003-95 | Performance Requirements for Water Pressure Reducing Valves for Domestic Water Supply Systems | |
1004-90 | Performance Requirements for Commercial Dishwashing Machines | |
1005-86 | Performance Requirements for Water Heater Drain Valves – with 1986 Revision | |
1006-89 | Performance Requirements for Residential Use (Household) Dishwashers | |
1007-92 | Performance Requirements for Home Laundry Equipment | |
1008-89 | Performance Requirements for Household Food Waste Disposer Units | |
1009-90 | Performance Requirements for Commercial Food Waste Grinder Units | |
1010-82 | Performance Requirements for Water Hammer Arresters – with 1982 Revision | |
1011-95 | Performance Requirements for Hose Connection Vacuum Breakers | |
1012-95 | Performance Requirements for Backflow Preventers with Intermediate Atmospheric Vent | |
1013-95 | Performance Requirements for Reduced Pressure Principle Backflow Preventers | |
1014-90 | Performance Requirements for Handheld Showers | |
1015-93 | Performance Requirements for Double Check Backflow Prevention Assembly – with 1993 Revision | |
1016-90 | Performance Requirements for Individual Thermostatic, Pressure Balancing and Combination Control Valves for Bathing Facilities | |
1017-90 | Temperature Actuated Mixing Valves for Primary Domestic Use | |
1018-86 | Performance Requirements for Trap Seal Primer Valves. Water Supply Fed – with 1986 Revision | |
1019-95 | Performance Requirements for Wall Hydrants, Freezeless, Automatic Draining, Anti-Backflow Types | |
1020-90 | Performance Requirements for Pressure Vacuum Breaker Assembly | Table 608.1 |
1022-96 | Backflow Preventer for Carbonated Beverage Machines | |
1024-94 | Performance Requirements for Dual Check Valve Type Backflow Preventers (for Residential Supply Service or Individual Outlets) | Table 608.1 |
1025-78 | Performance Requirements for Diverters for Plumbing Faucets with Hose Spray, Anti-Siphon Type, Residential Applications | |
1032-80 | Performance Requirements for Dual Check Valve Type Backflow Preventers; for Carbonated Beverage Dispensers – Post Mix-Types | |
1035-95 | Performance Requirements for Laboratory Faucet Backflow Preventers | |
1037-90 | Performance Requirements for Pressurized Flushing Devices for Plumbing Fixtures | |
1044-86 | Performance Requirements for Trap Seal Primer Valves; Drainage Type | |
1047-95 | Performance Requirements for Reduced Pressure Detector Assembly Backflow Preventers | Table 608.1 |
1048-95 | Performance Requirements for Double Check Detector Assembly Backflow Preventer | |
1052-94 | Performance Requirements for Hose Connection Backflow Preventers | |
1056-93 | Back Siphonage Vacuum Breaker | Table 608.1 |
5010-1013-1-91 | Field Test Procedure for Reduced Pressure Principle Assembly Using a Differential Pressure Gauge | |
5010-1015-1-91 | Field Test Procedure for a Double Check Valve Assembly Using a Duplex | |
5010-1015-2-91 | Field Test Procedure for a Double Check Valve Assembly Using a Differential Pressure Gauge – High- and Low-Pressure Hose Method | |
5010-1015-3-91 | Field Test Procedure for a Double Check Valve Assembly Using a Differential Pressure Gauge – High-Pressure Hose Method – with August 1992 Revisions | |
5010-1015-4-91 | Field Test Procedure for a Double Check Valve Assembly Using a Sight Tube | |
5010-1020-1-91 | Field Test Procedure for a Pressure Vacuum Breaker Assembly | |
5010-1047-1-91 | Field Test Procedure for a Reduced Pressure Detector Assembly Using A Differential Pressure Gauge | |
5010-1048-1-91 | Field Test Procedure for a Double Check Detector Assembly Using a Duplex Gauge | |
5010-1048-2-91 | Field Test Procedure for a Double Check Detector Assembly Using a Differential Pressure Gauge – High- and Low-Pressure Hose Method | |
5010-1048-3-91 | Field Test Procedure for a Double Check Detector Assembly Using a Differential Pressure Gauge – High-Pressure Hose Method | |
5010-1048-4-91 | Field Test Procedure for a Double Check Detector Assembly Using a Sight Tube | |
ASTM | American Society for Testing and Materials 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 | |
Standard Reference Number | Title | Referenced in code section number |
A 53-94 | Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated Welded and Seamless | |
A 74-94 | Specification for Cast Iron Soil Pipe and Fittings | |
A 377-99 | Standard Index of Specifications for Ductile-Iron Pressure Pipe | |
A 733-89 | Specification for Welded and Seamless Carbon Steel and Austenitic Stainless Steel Pipe Nipples | |
A 888-95 | Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Application | |
B 32-94 | Specification for Solder Metal | |
B 42-93 | Specification for Seamless Copper Pipe, Standard Sizes | |
B 43-94 | Specification for Seamless Red Brass Pipe, Standard Sizes | |
B 75-95a | Specification for Seamless Copper Tube | |
B 88-93a | Specification for Seamless Copper Water Tube | |
B 152-94 | Specification for Copper Sheet, Strip Plate and Rolled Bar | |
B 251-93 | Specification for General Requirements for Wrought Seamless Copper and Copper-Alloy Tube | |
B 302-92 | Specification for Threadless Copper Pipe | |
B 306-95a | Specification for Copper Drainage Tube (DWV) | Table 702.1, Table 1102.4 |
B 447-93 | Specification for Welded Copper Tube | |
B 687-96 | Specification for Brass, Copper, and Chromium-Plated Pipe Nipples | |
B 813-93 | Standard Specification for Liquid and Paste Fixtures for Soldering Applications of Copper and Copper Alloy Tube | |
B 828-92 | Practice for Making Capillary Joints by Soldering of Copper and Copper Alloy Tube and Fittings | |
C 4-95 | Specification for Clay Drain Tile | |
C 14-95 | Specification for Concrete Sewer, Storm Drain, and Culvert Pipe | Table 702.3, Table 1102.4 |
C 76-95a | Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe | Table 702.3, Table 1102.4 |
C 425-95 | Specification for Compression Joints for Vitrified Clay Pipe and Fittings | |
C 428-92 | Specification for Asbestos-Cement Nonpressure Sewer Pipe | Table 1102.4 |
C 443-94 | Specification for Joints for Circular Concrete Sewer and Culvert Pipe, Using Rubber Gaskets | |
C 508-94 | Specification for Asbestos-Cement Underdrain Pipe | Table 1102.5 |
C 564-95a | Specification for Rubber Gaskets for Cast Iron Soil Pipe and Fittings | |
C 700-95 | Specification for Vitrified Clay Pipe, Extra Strength, Standard Strength, and Perforated | |
C 1053-95 | Specification for Borosilicate Glass Pipe and Fittings for Drain, Waste, and Vent (DWV) Applications | |
C 1173-97 | Specifications for Flexible Transition Couplings for Underground Piping Systems | |
C 1277-98 | Standard Specification for Shielded Couplings Joining Hubless Cast-iron Soil Pipe and Fittings | |
D 1869-95 | Specification for Rubber Rings for Asbestos-Cement Pipe | |
D 2564-93 | Specification for Solvent Cements for Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings | |
D 2661-96 | Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste, and Vent Pipe and Fittings | Table 1102.4 |
D 2665-96 | Specification for Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings | |
D 2729-96 | Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings | Table 1102.4, 1102.5 |
D 2751-96 | Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings | Table 1102.4 |
D 2846-96 | Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Hot and Cold Water Distribution Systems | |
D 2855-96 | Standard Practice for Making Solvent-Cemented Joints with Poly (Vinyl Chloride) (PVC) Pipe and Fittings | |
D 2949-96 | Specification for 3.25-in Outside Diameter Poly (Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent Pipe and Fittings | Table 702.1 |
D 3034-96 | Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings | Table 1102.4 |
D 3212-96 | Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric Seals | |
D 3311-94 | Specification for Drain, Waste and Vend (DWV) Plastic Fittings Patterns | Table 702.4 |
D 4551-96 | Specification for Poly (Vinyl Chloride) (PVC) Plastic Flexible Concealed Water-Containment Membrane | |
F 437-96 | Specification for Threaded Chlorinated Poly (Vinyl Chloride) (PVC) Plastic Pipe Fittings, Schedule 80 | Table 605.6 |
F 438-93 | Specification for Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 40 | Table 605.6 |
F 439-93a | Specification for Socket-Type Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe Fittings, Schedule 80 | Table 605.6 |
F 441-94 | Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe, Schedules 40 and 80 | Table 605.5 |
F 442-94 | Specification for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe (SDR- PR) | Table 605.5 |
F 477-96 | Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe | |
F 493-93a | Specification for Solvent Cements for Chlorinated Poly (Vinyl Chloride) (CPVC) Plastic Pipe and Fittings | |
F 628-96 | Specification for Acrylonitrile-Butadiene-Styrene (ABS) Schedule 40 Plastic Drain, Waste and Vent Pipe with Cellular Core | Table 1102.4 |
F 656-96 | Specification for Primers for Use in Solvent Cement Joints of Poly (Vinyl Chloride) (PVC) Plastic Pipe and Fittings | |
F 891-96 | Specification for Coextruded Poly (Vinyl Chloride) (PVC) Plastic Pipe with a Cellular Core | Table 1102.4, Table 1102.5 |
F 1412-99 | Specification for Polyolefin Pipe and Fittings for Corrosive Waste Drainage Systems | |
AWWA | American Water Works Association 6666 West Quincy Avenue Denver, CO 80235 | |
Standard Reference Number | Title | Referenced in code section number |
C 104-95 | Cementmortar Lining for Ductileiron Pipe and Fittings for Water | |
C 110-93 | Standard for Ductile-Iron and Gray-Iron Fittings, 3 Inch through 48 Inches, for Water and Other Liquids | |
C 111-95 | Rubber Gasket Joints for Ductile Iron Pressure Pipe and Fittings | |
C 115-99 | Flanged Ductile-Iron Pipe with Ductile-Iron or Gray-Iron Threaded Flanges | |
C 151-91 | Standard for Ductile-Iron Pipe, Centrifugally Cast for Water or Other Liquids | |
C 153-00 | Ductile-Iron Compact Fittings for Water Service | Table 605.6 |
C 510-95 | Double Check Valve Backflow-Prevention Assembly | |
C 511-92 | Reduced-Pressure Principle Backflow-Prevention Assembly | |
CSA | Canadian Standards Association 178 Rexdale Blvd. Rexdale (Toronto), Ontario, Canada M9W IR3 | |
Standard Reference Number | Title | Referenced in code section number |
A257.1-92 | Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings | Table 702.3, Table 1102.4 |
A257.3-92 | Joints for Circular Concrete Sewer and Culvert Pipe, Manhole Sections, and Fittings Using Rubber Gaskets | |
B45.1-94 | Ceramic Plumbing Fixtures | |
B45.2-94 | Enameled Cast-Iron Plumbing Fixtures | |
B45.3-94 | Porcelain Enameled Steel Plumbing Fixtures | |
B45.4-94 | Stainless-Steel Plumbing Fixtures | |
B45.5-94 | Plastic Plumbing Fixtures | |
B64.7-94 | Vacuum Breakers, Laboratory Faucet Type (LFVB) | Table 608.1 |
B64.10-94 | Manual for the Selection, Installation, Maintenance and Field Testing of Backflow Prevention Devices | |
B79-79 | Floor, Area and Shower Drains, and Cleanouts for Residential Construction | |
B137.6-83 | CPVC Pipe, Tubing and Fittings for Hot and Cold Water Distribution Systems | Table 605.5 |
B181.1-96 | ABS Drain, Waste, and Vent Pipe and Pipe Fitting | Table 702.1 |
B182.2-95 | PVC Sewer Pipe and Fittings (PSM Type) | |
CAN/CSA-A257.2-92 | Reinforced L Circular Concrete Culvert, Storm Drain, Sewer Pipe and Fittings | Table 702.3, Table 1102.4 |
CAN/CSA-B64.1.1-94 | Vacuum Breakers, Atmoshperic Type (AVB) | |
CAN/CSA-B64.2-94 | Vacuum Breakers, Hose Connection Type (HCVB) | |
CAN/CSA-B64.2.2-94 | Vacuum Breakers, Hose Connection Type (HCVB) with Automatic Draining Feature | |
CAN/CSA-B64.3-94 | Backflow Preventers, Dual Check Valve Type with Atmospheric Port (DCAP) | |
CAN/CSA-B64.4-94 | Backflow Preventers, Reduced Pressure Principle Type (RP) | |
CAN/CSA-B125-94 | Plumbing Fittings | |
CAN/CSA-B137.3-93 | Rigid Poly (Vinyl Chloride) (PVC) Pipe for Pressure Applications | |
CAN/CSA-B181.1-96 | ABS Drain, Waste, and Vent Pipe and Pipe Fittings | |
CAN/CSA-B181.2-90 | PVC Drain, Waste, and Vent Pipe and Pipe Fittings | |
CAN/CSA-B182.1-92 | Plastic Drain and Sewer Pipe and Pipe Fittings | |
CAN/CSA-B182.2-83 | PVC Sewer Pipe and Fittings (PSM Type) | |
CAN/CSA-B182.4-92 | Profile PVC Sewer Pipe and Fittings | Table 1102.4, Table 1102.5 |
CAN/CSA-B602-90 | Mechanical Couplings for Drain, Waste, and Vent Pipe and Sewer Pipe | |
CSA-B45-88 | (Supplement 1) – Hydromassage Bathtubs | |
CISPI | Cast Iron Soil Pipe Institute Suite 419 5959 Shallowford Road Chattanooga, TN 37421 | |
Standard Reference Number | Title | Referenced in code section number |
301-95 | Specification for Hubless Cast Iron Soil Pipe and Fittings for Sanitary and Storm Drain, Waste and Vent Piping Applications | |
310-95 | Specification for Coupling for Use in Connection with Cast-Iron Soil Pipe and Fittings for Sanitary and Storm Drain Waste and Vent Piping Applications |
FS | Federal Specification General Service Administration 7th & D Streets Specification Section, Room 6039 Washington, DC 20407 | |
Standard Reference Number | Title | Referenced in code section number |
TT-P-1536a-75 | Federal Specification for Plumbing Fixture Setting Compound |
NSF | National Sanitation Foundation 3475 Plymouth Road P.O. Box 130140 Ann Arbor, MI 48113-0140 | |
Standard Reference Number | Title | Referenced in code section number |
14-90 | Plastic Piping Components and Related Materials | |
42-88 | Drinking Water Treatment Units – Aesthetic Effects | |
53-96 | Drinking Water Treatment Units – Health Effects | |
58-96 | Reverse Osmosis Drinking Water Treatment Systems | |
61-95 | Drinking Water System Components – Health Effects |
PDI | Plumbing and Drainage Institute 1106 West 77th Street, South Drive Indianapolis, IN 46260-3318 | |
Standard Reference Number | Title | Referenced in code section number |
G101-85 | Testing and Rating Procedure for Grease Interceptors with Appendix of Sizing and Installation Data |