18-29-1102.5  Subsoil drain pipe.
   Subsoil drains shall be open-jointed, horizontally split or perforated pipe conforming to one of the standards listed in Table 18-29-1102.5, except corrugated pipe is not allowed and the polyvinyl chloride (PVC) used for subsurface soil drainage in stormwater management shall be as stipulated in the latest edition of the "Regulations for Sewer Construction and Stormwater Management" of the department of water management.
Table 18-29-1102.5
Subsoil Drain Pipe
 
Material
Standard
Cast-iron pipe
ASTM A 74; ASTM A 888; CISPI 301
Polyvinyl chloride (PVC) plastic pipe (Type Sewer Pipe, PS25, PS50 or PS100)
ASTM D 2729; ASTM D 3034; ASTM F891; CAS-B182.2; CSA CAN/CSA-B182.4; SDR 35
Vitrified clay pipe
ASTM C 4; ASTM C 700
Polyvinyl chloride (PVC) plastic pipe (Schedule 40)
ASTM D 2729; PS25, PS50, PS100; ASTM D 3034, SDR 26, SDR 35; ASTM F891; CSA-B182.2; CSA CAN/CSA-B182.4
 