Skip to code content (skip section selection)
Compare to:

You are viewing an archived code

18-29-702.1  Above-ground sanitary drainage and vent pipe.
   Above-ground soil, waste and vent pipe shall conform to the respective standard listed in Table 18-29-702.1. The use of polyvinyl chloride (PVC) plastic pipe shall be limited to buildings three stories or less in height intended for residential occupancy. The use of DWV copper tubing shall not be permitted in any structure or plumbing system.
(Amend. Coun. J. 3-27-02, p. 82090, § 3)
Table 18-29-702.1
Above-Ground Drainage and Vent Pipe
Material
Standard
Material
Standard
Brass pipe
ASTM B 43
Cast-iron pipe hub & spigot c
ASTM A 74; CISPI 301; ASTM A 888
Cast iron pipe hubless a
ASTM A 888; CISPI 301
Copper or copper-alloy pipe
ASTM B 42; ASTM B 302
Copper or copper-alloy tubing (Type K, L, or M)
ASTM 75; ASTM B 88; ASTM B 251; ASTM B 306
Galvanized steel pipe
ASTM A 53
Glass pipe b
ASTMC 1053
Ductile iron pipe b
AWWA C151; AWWA C115
Polyvinyl chloride (PVC) a plastic pipe
(Schedule 40)
ASTM D 2665; ASTM D 2449; ASTM F 891 d;
CSA CAN/CSA-B181.2
High silicon content cast iron pipe b
ASTM A 377-1984
Polypropylene or Polyvinylfluorodene (PVDF) a, b
ASTM F1412
 
a In any building three stories or less in height for residential occupancy only.
b Approved for acid waste only, on private system, not to be connected to the public sewer.
c Lead and oakum joints only.
d Use shall be limited to gravity drainage and venting only and shall not be allowed for pressurized drain, waste or venting applications.
(Amend Coun. J. 3-27-02, p. 82090, § 3; Amend Coun. J. 7-29-15, p. 3537, § 4)