18-29-418.2.1  Facilities with no range oven.
   Sinks installed in lunchrooms, pantries, break rooms and other similar facilities where no range or oven is installed shall not be required to have a grease interceptor. Installation of a microwave oven in such facilities shall require the installation of a grease interceptor.
(Amend Coun. J. 3-27-02, p. 82090, § 3)
18-29-419  Urinals.
18-29-419.1  Approval.
   Urinals shall conform to ASME A112.19.2, CSA B45.1 or CSA B45.5. Urinals shall conform to the water consumption requirements of Section 18-29-604.4. Urinals shall conform to the hydraulic performance requirements of ASME A 112.19.6, CSA B45.1 or CSA B45.5.
18-29-419.2  Substitution for water closets.
   In each bathroom or toilet room, urinals shall not be substituted for more than 50 percent of the required water closets.
18-29-419.3  Urinals for public or employee toilet facilities.
   Urinals for public or employee toilet facilities shall have a visible trap seal.