Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
Subdivision 403 - High-Rise buildings
Subdivision 406 - Motor-Vehicle-Related Occupancies
Subdivision 407 - Special Institutional
Subdivision 411 - Special Amusement Buildings
Subdivision 413 - Combustible Storage
Subdivision 414 - Hazardous Materials
CHAPTER 4-108 FILLING STATIONS
CHAPTER 4-115 RESERVED*
CHAPTER 15-20 EXPLOSIVES AND FIREWORKS
CHAPTER 15-24 FLAMMABLE LIQUIDS
CHAPTER 15-26 FUME AND FLAMMABLE COMPRESSED GASES
CHAPTER 15-28 HAZARDOUS MATERIALS AND COMBUSTIBLE SOLIDS
ARTICLE I. GENERAL (15-28-010 et seq.)
ARTICLE II. HAZARDOUS CHEMICALS (15-28-040 et seq.)
ARTICLE III. OXIDIZING MATERIALS (15-28-200 et seq.)
ARTICLE IV. NITROMETHANE (15-28-230 et seq.)
ARTICLE V. ASPHALT, TAR, PITCH, RESIN AND PARAFFIN (15-28-260 et seq.)
ARTICLE VI. AMMONIUM NITRATE (15-28-300 et seq.)
ARTICLE VII. ORGANIC PEROXIDES (15-28-340 et seq.)
ARTICLE VIII. POTENTIALLY EXPLOSIVE CHEMICALS (15-28-360 et seq.)
ARTICLE IX. HIGHLY TOXIC MATERIALS (15-28-380 et seq.)
ARTICLE X. CORROSIVE LIQUIDS (15-28-390 et seq.)
ARTICLE XI. RADIOACTIVE MATERIALS (15-28-490 et seq.)
ARTICLE XII. COMBUSTIBLE SOLIDS (15-28-500 et seq.)
ARTICLE XIII. SMOKEHOUSES AND SMOKEROOMS (15-28-680 et seq.)
ARTICLE XIV. LUMBER DRY KILNS (15-28-710 et seq.)
ARTICLE XV. MISCELLANEOUS COMBUSTIBLES (15-28-730 et seq.)
ARTICLE XVI. MANUFACTURE, TRANSPORTATION OR SALE OF MATCHES (15-28-760 et seq.)
ARTICLE XVII. NITROCELLULOSE PRODUCTS (15-28-810 et seq.)
ARTICLE XVIII. NITROCELLULOSE (15-28-940 et seq.)
ARTICLE XIX. MOTION PICTURE TRIAL EXHIBITION ROOMS (15-28-1000 et seq.)
ARTICLE XX. HAZARDOUS DUSTS (15-28-1050 et seq.)
ARTICLE XXI. UNDERGROUND STORAGE TANK VIOLATIONS. (15-28-1220 et seq.)
Subdivision 421 - Special Detailed Requirements
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
15-28-1120  Grain elevators and malt houses.
   Every grain elevator, malt house and similar building shall be so situated that it will not be so hazardous as to constitute a nuisance or be a menace to the safety of the public or to the adjacent property.
(Prior code §  92-101)
15-28-1130  Construction of grain bleachers.
   Every grain bleacher shall be of Type IA construction. No combustible construction shall be used between a grain bleacher and any other building.
(Prior code §  92-102)
15-28-1140  Construction of cereal, feed, flour, grist and starch mills.
   Every building, or part of a building, designed, erected, altered or converted for the purposes of a cereal mill, feed mill, flour mill, grist mill, or starch mill and in which more than 500 pounds of any cereal, feed, flour, grist or starch is produced during any 24-hour period shall be of Type IA, IB or IC construction.
(Prior code §  92-103)
15-28-1150  Construction of grain elevators and malt houses.
   Every grain elevator, malt house and similar building shall be of Type IA construction.
(Prior code §  92-104)
15-28-1160  Marine tower.
   In any existing grain elevator, malt house or similar building, the exterior walls of the marine tower, which is defined as that part of the structure in which is located the machinery for conveying grain from boats to the conveying bridge, and thence to the bins; and the exterior walls of cupolas and conveyor bridge, which is that part of the structure housing the conveying and elevating machinery above the fireproof bins, may, if the same require replacement, be replaced with galvanized corrugated steel, protected metal or asbestos corrugated material fastened to the steel structure by rust-proof bolts.
(Prior code §  92-105)
15-28-1170  Bleaching operations.
   (a)   Storage. Sodium peroxide and sulfur in excess of one day's supply shall be stored in a separate and suitable building. The user shall notify the fire prevention bureau, by notarized letter, of the amount used in 24 hours. Upon any change in that amount, the user shall notify the fire prevention bureau within 24 hours.
   (b)   Construction of Pots. Sulfur pots shall be so constructed that if the sulfur boils over it cannot drop on combustible material. In broom corn factories, metal hoods shall be provided to prevent corn falling into or against the pots.
   (c)   Location of Grain Bleachers. Grain bleachers shall be set at least 25 feet from frame grain elevators but may be set not closer than six feet to a brick or fireproof elevator; provided, however, there are no unprotected openings in the elevator wall within 25 feet of the bleacher. Metal spouts connecting the bleacher with the elevator shall each be provided with two automatic dampers, one damper at each end of metal spout. All conveyors connecting the bleacher with the elevator shall be metal screw conveyors in metal or concrete casings. No combustible material shall be used between bleacher and elevator.
   (d)   Location of Sulfur Furnace. The sulfur- burning furnace shall be set at least 25 feet distant from bleacher in the opposite direction from the elevator and shall be of fireproof construction and unenclosed, unless it be an enclosure of fireproof construction; provided, however, that when conditions are such that the sulfur furnace cannot be located 25 feet from the bleacher, it may be located closer, but the length of the sulfur fumes pipe shall in no case be less than 25 feet.
(Prior code §  92-106)
15-28-1180  Equipment.
   Every conveyor, duct, and spout between a grain bleacher and any grain elevator or other building shall be enclosed in a casing constructed of noncombustible material. Conveyors, ducts and spouts shall have an automatic closing fire damper at each end, having a fire- resistive value of not less than 45 minutes. Every sulfur- burning furnace for a grain bleacher shall be so located that the length of the sulfur fumes pipe will not be less than 25 feet, and every such furnace shall be separated by a distance of not less than 25 feet from any grain elevator, and from any other building except a grain bleacher.
(Prior code §  92-107)
15-28-1190  Fire protection.
   Every conveyor and spout between a grain bleacher and any other building shall be provided with a damper at each end. Such dampers shall be of construction having a 60-minute fire-resistive value, and shall be so arranged and equipped as to close automatically in case of fire by the release of a fusible link or by the actuation of a standard thermostatic releasing device.
(Prior code §  92-108)
15-28-1200  Dust removal.
   (a)   Daily Removal. In all grain elevators, grain bleachers and other buildings or rooms housing dust- producing processes or occupancies, accumulations of dust shall be prevented by daily removal. Dust collecting systems, required under Chapter 15-28 of this Code, shall be maintained in efficient operating condition.
(Prior code §  92-109)
Loading...