Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
Subdivision 403 - High-Rise buildings
Subdivision 406 - Motor-Vehicle-Related Occupancies
Subdivision 407 - Special Institutional
Subdivision 411 - Special Amusement Buildings
Subdivision 413 - Combustible Storage
Subdivision 414 - Hazardous Materials
CHAPTER 4-108 FILLING STATIONS
CHAPTER 4-115 RESERVED*
CHAPTER 15-20 EXPLOSIVES AND FIREWORKS
CHAPTER 15-24 FLAMMABLE LIQUIDS
CHAPTER 15-26 FUME AND FLAMMABLE COMPRESSED GASES
CHAPTER 15-28 HAZARDOUS MATERIALS AND COMBUSTIBLE SOLIDS
Subdivision 421 - Special Detailed Requirements
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
15-28-710  Construction requirements.
   A kiln or room designed, erected, altered or converted for the purposes of drying lumber, wood products or wooden articles by artificial heat shall have an enclosure of two-hour fire-resistive construction, if it has a floor area of 500 square feet or less, and of three-hour fire-resistive construction if it has a floor area of more than 500 square feet. No such kiln or room shall have any opening except a doorway or doorways between such room and any other part of the building. Every doorway into any such room shall be provided with a door of the character as required by Chapter 15-12 of this Code.
(Prior code §  92-60)
15-28-720  Heating.
   Only steam or hot water shall be used for heating a kiln or room for the drying of lumber.
(Prior code §  92-61)
ARTICLE XV.  MISCELLANEOUS COMBUSTIBLES (15-28-730 et seq.)
15-28-730  Storage or baling of wastepaper.
   Every room designed, intended or used for the storage or baling of wastepaper in a building of Type IA, IB, IC or II construction shall have an enclosure of not less than two-hour fire-resistive construction with every doorway in such an enclosure having a Class B fire door and every window therein a fire window. Every such room in a building of Type IIIA, IIIB or IIIC construction shall have walls and ceiling of not less than one-hour fire-resistive construction with every doorway in such an enclosure having a Class C fire door.
(Prior code §  92-62)
15-28-740  Disposal of wastepaper.
   Except as otherwise herein specifically provided, the floor of every room used for the manufacture or sale of flammable articles or merchandise, or upon which there accumulates any amount of flammable waste material, or waste material tending to produce spontaneous combustion, shall be thoroughly cleaned and all such waste material shall be removed therefrom at least once every 24 hours.
   All such material shall be either destroyed as soon as removed, as required by this section, or it may be kept in a room, the construction and location of which shall be subject to the approval of the fire commissioner, and in such case all such material shall be removed from such room and from the building in which such room is located at least once a week.
(Prior code § 92-63; Amend Coun. J. 5-18-16, p. 24131, § 158)
Loading...