Ventilators. All ventilators, overbalanced sash and similar devices, required by this Code, designed to afford pressure relief in case of explosion, shall be inspected at intervals sufficiently frequent to insure their constant operating efficiency.
(Prior code § 92-98)
Every grain bleacher shall be separated by a distance of not less than six feet from any other building; provided, however, that no grain bleacher shall be nearer than 25 feet to any window, or doorway of any other building unless such window is a fire window, or unless such doorway is provided with Class D fire floor.
(Prior code § 92-100)
Every building, or part of a building, designed, erected, altered or converted for the purposes of a cereal mill, feed mill, flour mill, grist mill, or starch mill and in which more than 500 pounds of any cereal, feed, flour, grist or starch is produced during any 24-hour period shall be of Type IA, IB or IC construction.
(Prior code § 92-103)
In any existing grain elevator, malt house or similar building, the exterior walls of the marine tower, which is defined as that part of the structure in which is located the machinery for conveying grain from boats to the conveying bridge, and thence to the bins; and the exterior walls of cupolas and conveyor bridge, which is that part of the structure housing the conveying and elevating machinery above the fireproof bins, may, if the same require replacement, be replaced with galvanized corrugated steel, protected metal or asbestos corrugated material fastened to the steel structure by rust-proof bolts.