15-28-1100  Grounding of equipment.
   In every grinding or dust-producing area, all metal parts of machinery or equipment shall be positively grounded to prevent static electricity buildup and smoking or the use of any device employing an open flame is prohibited.
(Prior code §  92-99)
15-28-1110  Grain bleachers.
   Every grain bleacher shall be separated by a distance of not less than six feet from any other building; provided, however, that no grain bleacher shall be nearer than 25 feet to any window, or doorway of any other building unless such window is a fire window, or unless such doorway is provided with Class D fire floor.
(Prior code §  92-100)
15-28-1120  Grain elevators and malt houses.
   Every grain elevator, malt house and similar building shall be so situated that it will not be so hazardous as to constitute a nuisance or be a menace to the safety of the public or to the adjacent property.
(Prior code §  92-101)
15-28-1130  Construction of grain bleachers.
   Every grain bleacher shall be of Type IA construction. No combustible construction shall be used between a grain bleacher and any other building.
(Prior code §  92-102)
15-28-1140  Construction of cereal, feed, flour, grist and starch mills.
   Every building, or part of a building, designed, erected, altered or converted for the purposes of a cereal mill, feed mill, flour mill, grist mill, or starch mill and in which more than 500 pounds of any cereal, feed, flour, grist or starch is produced during any 24-hour period shall be of Type IA, IB or IC construction.