13-96-1190  Shooting range facility requirements.
   (a)   The shooting range facility must comply with all applicable code sections as determined by the occupancy classification. Where the ancillary spaces are under the direct control and management of the owner of the shooting range, no mixed occupancy separation is required between the shooting range and the ancillary spaces. Where the ancillary spaces are not under the direct control and management of the owner of the shooting range, or where the shooting range is constructed without ancillary spaces, the mixed occupancy separation shall be as set forth in Table 13-56-280. The shooting range occupancy classification to determine required mixed occupancy separations shall be Class E Business. The need for mixed occupancy separations is not determined by the amount of area occupied by the ancillary spaces as a percent of the total area of the shooting range facility.
   (b)   Exiting for the shooting range facility shall not be through the shooting range.
   (c)   (1)   The shooting range facility may include the following uses: office space, mercantile, training, classroom or spectator space, general patron use space, locker rooms including showers, range master booth, storage of ammunition, and storage of firearms.
      (2)   The shooting range facility shall include the following uses:
         a)   a shooting range;
         b)   security entrance;
         c)   toilet facilities in compliance with Chapter 18-29 and Section 13-96-1220; and
   (d)   All occupancies within the shooting range facility must be protected from any projectiles straying from the shooting range.
(Added Coun. J. 7-6-11, p. 3073, § 8; Amend Coun. J. 6-25-14, p. 83727, § 9)