13-96-1230  Electrical requirements.
   (a)   Every shooting range facility shall be constructed with a system II (battery pack) emergency lighting in conformance with the requirements of Section 14E-7-700.
   (b)   The shooting range shall be constructed to be free of excessive glare and major differences in light levels. Floors and ceilings shall be designed to provide light reflection.
   (c)   The lighting design and construction of every shooting range shall include the following:
      (1)   General lighting shall provide uniform light levels over the entire range area and adjoining areas;
      (2)   Local lighting shall supplement general lighting along the firing line to provide better visibility;
      (3)   Semi-direct lighting shall be provided to direct 60 to 90 percent of the lighting on the target.
(Added Coun. J. 7-6-11, p. 3073, § 8; Amend Coun. J. 9-6-17, p. 55278, Art. II, § 36)