Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
14X-5-505.13 Exit signs.
Exit signs must comply with Section 1013 of the Chicago Building Code.
Exceptions:
1.   Existing exit signs lettered "STAIRS" or "STAIRWAY" may remain at locations where a "STAIR" sign is required by the Chicago Building Code.
2.   Existing exit signs installed prior to December 31, 1960, and otherwise required to be lettered "STAIR," may be lettered "EXIT."
14X-5-505.14 Handrails.
Handrails must be provided in accordance with Section 14X-3-306.1.
14X-5-505.14.1 Location.
Stairways must have handrails on at least one side. Handrails must be located so that all portions of the stairway width required for egress capacity are within 44 inches (1118 mm) of a handrail.
Exception: Aisle stairs provided with a center handrail are not required to have additional handrails.
14X-5-505.15 Guards.
Guards must be provided in accordance with Section 14X-3-306.2.
14X-5-505.16 Corridors.
The width of a corridor must be sufficient for the occupant load served and not less than 36 inches (914 mm). Corridors serving an occupant load greater than 30 and openings in these corridors must provide an effective barrier to resist the movement of smoke. Transoms, louvers, doors, and other openings must be kept closed or be self-closing.
Exceptions:
1.   Corridors in occupancies other than in Group H, that are equipped throughout with an automatic sprinkler system.
2.   Corridors that are in accordance with the Chicago Building Code.
(Amend Coun. J. 2-19-20, p. 14473, Art. V, § 33; Amend Coun. J. 1-26-22, p. 43756, Art. IV, § 2)
14X-5-505.17 Aisles and aisle accessways.
The width of aisles and aisle accessways must be sufficient for the occupant load served and not less than 28 inches (711 mm).
Exceptions:
1.   Aisles and aisle accessways within individual dwelling units or sleeping units.
2.   Aisles and aisle accessways in rooms or spaces uses for assembly purposes that comply with Section 1029 of the Chicago Building Code.
(Added Coun. J. 1-26-22, p. 43756, Art. IV, § 3)
14X-5-506 LIFE SAFETY COMPLIANCE PLAN.