Escalators serving as required exits shall be enclosed and protected as required for stairways in Section 15-8-120.
(Prior code § 67-14.5)
Exterior stairs required as a means of exit shall comply with all applicable requirements for interior stairs and with the provisions of Sections 13-160-590 to 13-160-620, inclusive.
(Prior code § 67-15)
Except in residential units, all openings within 15 feet of an exterior stair shall be protected with fire doors, windows or shutters complying with the requirements of Section 15-8-070.
(Prior code § 67-15.2)
Fire escapes, when permitted, shall comply with the provisions of Sections 13-160-640 and 13-160-650.
Fire escapes shall not be permitted except where such exits now serve existing buildings and except as approved by the building commissioner for existing buildings where additional exits are necessary and conditions do not permit the use of more adequate exit facilities.
(Prior code § 67-16; Amend Coun. J. 9-13-89, p. 4604; Amend Coun. J. 3-5-03, p. 104990, § 34; Amend Coun. J. 11-13-07, p. 14999, Art. II, § 1)