Skip to code content (skip section selection)
Compare to:

You are viewing an archived code

13-160-200  Measurement of width.
   (a)   The width of doors shall be taken as the nominal width of the door leaf. The reduction of clear width of doorway opening resulting from door stops and thickness of door leaf when open shall not exceed two inches for each unit of exit width.
   (b)   The width of stairs shall be the clear width between walls, railings or newel posts. Handrails may project not more than four inches on each side into the required width. When doors open onto a stair landing, 75 percent of the required exit width shall be maintained beyond the edge of such door when opened in any position.
   (c)   The width of corridors shall be the clear, unobstructed width. Doors opening into a required exit corridor shall not restrict the required width when opened in any position.
(Prior code § 67-7.3)