BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
CHAPTER 15-8 FIRE-RESISTIVE REQUIREMENTS
15-8-010 Fire walls.
15-8-020 Definition.
15-8-030 Construction.
15-8-040 Offset construction.
15-8-050 Parapets.
15-8-060 Openings.
15-8-070 Exterior walls - Requirements.
15-8-080 Exterior walls - Construction.
15-8-081 Exterior insulating and finish systems.
15-8-082 Test data required.
15-8-083 Multistory buildings.
15-8-084 Required fastening.
15-8-085 Labeling.
15-8-086 Moisture control.
15-8-090 Sloping walls.
15-8-100 Parapets.
15-8-110 Protection of openings.
15-8-120 Protection of stairs, shafts and vertical openings.
15-8-130 Enclosure partitions.
15-8-140 Stairway enclosures.
15-8-150 Elevator and escalator enclosures.
15-8-160 Enclosure of pipe shafts and ducts.
15-8-170 Enclosure of wells and chutes.
15-8-180 Protection of openings.
15-8-190 Enclosure of heating plants and boiler rooms.
15-8-200 Protection not required.
15-8-210 Two-hour protection required.
15-8-220 One-hour protection required.
15-8-230 Protection of openings.
15-8-240 Other enclosures and separations.
15-8-250 Partitions.
15-8-260 Fire-resistive requirements.
15-8-270 Subdividing partitions.
15-8-280 Exterior trim.
15-8-290 Definition.
15-8-300 Cornices, gutters and leaders.
15-8-310 Balconies and bay windows.
15-8-320 Porches.
15-8-321 Decks.
15-8-322 Rooftop decks.
15-8-323 Weather-protected entries.
15-8-324 Open stairs.
15-8-325 Reserved.
15-8-326 Pergolas, trellises, arbors, and privacy screens.
15-8-330 Roof coverings.
15-8-340 Classification.
15-8-350 Materials.
15-8-360 Use.
15-8-370 Interior wall and ceiling finish and trim.
15-8-380 Interior wall and ceiling finishes.
15-8-390 Interior trim.
15-8-400 Classification of materials.
15-8-410 General requirements.
15-8-420 Requirements for interior wall and ceiling finish.
15-8-430 Interior trim.
15-8-440 Floor coverings.
15-8-450 Flooring.
15-8-460 Sleepers.
15-8-470 Insulation.
15-8-480 Fire-resistive or noncombustible construction.
15-8-490 Heavy timber construction.
15-8-500 Stairways and exitways.
15-8-510 Roof structures.
15-8-520 Skylights and monitors.
15-8-530 Penthouses.
15-8-540 Mansard and sloping roofs.
15-8-550 Towers.
15-8-560 Miscellaneous roof structures.
15-8-570 Firestopping.
15-8-580 Materials.
15-8-590 Walls and partitions.
15-8-600 Roof spaces.
15-8-610 Stairs.
15-8-620 Floors and roofs.
15-8-630 Chimneys.
15-8-640 Pipes and shafts.
15-8-660 Air intakes in courts and yards.
CHAPTER 15-12 FIRE-RESISTIVE MATERIALS AND CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
15-8-010  Fire walls.
   Fire walls, when required, shall comply with the requirements of Sections 15-8-020 to 15-8-060, inclusive.
(Prior code §  62-1)
15-8-020  Definition.
   A “fire wall” is hereby defined as a wall which subdivides a building into limited fire areas or which separates two or more buildings to prevent the spread of fire and which extends continuously through all stories to a level above the roof.
(Prior code §  62-1.1)
15-8-030  Construction.
   All fire walls shall be constructed of noncombustible materials providing fire resistance not less than the following:
   (a)   Walls exceeding 14 feet in unsupported height – eight hours;
   (b)   Walls not exceeding 14 feet in unsupported height – four hours.
   All structural members supporting fire walls shall be of construction providing fire resistance not less than that required for the wall.
(Prior code §  62-1.2)
15-8-040  Offset construction.
   If fire walls are offset at intermediate floor levels, the offset floor and its supporting construction shall provide fire resistance not less than that required for the wall.
(Prior code §  62-1.3)
15-8-050  Parapets.
   Fire walls shall extend not less than 36 inches above the roof, except that the fire walls may extend to the roof level when the roof is of fire-resistive construction for a distance of not less than 40 feet on each side of the wall.
(Prior code §  62-1.4)