(a) In buildings of Types I-A, I-B, I-C and II construction, partition framing shall be of either or both of the following materials:
(1) Noncombustible materials;
(2) Fire-retardant treated wood within assemblies of one-hour maximum rating.
(b) In buildings of Type III-A construction partition framing shall be of heavy timber construction providing fire resistance as required for floor construction or roof construction above or shall be of noncombustible materials or fire-retardant treated wood within a one-half-hour to one-hour fire-rated assembly.
(c) In buildings of Types III-B and IV-A construction, partitions shall be of either of the following types:
(1) Combustible construction protected to provide fire resistance of not less than one-half hour;
(2) Noncombustible construction.
(Prior code § 62-6.1)