Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
Subdivision 403 - High-Rise buildings
Subdivision 406 - Motor-Vehicle-Related Occupancies
Subdivision 407 - Special Institutional
Subdivision 411 - Special Amusement Buildings
Subdivision 413 - Combustible Storage
Subdivision 414 - Hazardous Materials
CHAPTER 4-108 FILLING STATIONS
CHAPTER 4-115 RESERVED*
CHAPTER 15-20 EXPLOSIVES AND FIREWORKS
CHAPTER 15-24 FLAMMABLE LIQUIDS
CHAPTER 15-26 FUME AND FLAMMABLE COMPRESSED GASES
CHAPTER 15-28 HAZARDOUS MATERIALS AND COMBUSTIBLE SOLIDS
ARTICLE I. GENERAL (15-28-010 et seq.)
ARTICLE II. HAZARDOUS CHEMICALS (15-28-040 et seq.)
ARTICLE III. OXIDIZING MATERIALS (15-28-200 et seq.)
ARTICLE IV. NITROMETHANE (15-28-230 et seq.)
ARTICLE V. ASPHALT, TAR, PITCH, RESIN AND PARAFFIN (15-28-260 et seq.)
ARTICLE VI. AMMONIUM NITRATE (15-28-300 et seq.)
ARTICLE VII. ORGANIC PEROXIDES (15-28-340 et seq.)
ARTICLE VIII. POTENTIALLY EXPLOSIVE CHEMICALS (15-28-360 et seq.)
ARTICLE IX. HIGHLY TOXIC MATERIALS (15-28-380 et seq.)
ARTICLE X. CORROSIVE LIQUIDS (15-28-390 et seq.)
ARTICLE XI. RADIOACTIVE MATERIALS (15-28-490 et seq.)
ARTICLE XII. COMBUSTIBLE SOLIDS (15-28-500 et seq.)
ARTICLE XIII. SMOKEHOUSES AND SMOKEROOMS (15-28-680 et seq.)
ARTICLE XIV. LUMBER DRY KILNS (15-28-710 et seq.)
ARTICLE XV. MISCELLANEOUS COMBUSTIBLES (15-28-730 et seq.)
ARTICLE XVI. MANUFACTURE, TRANSPORTATION OR SALE OF MATCHES (15-28-760 et seq.)
ARTICLE XVII. NITROCELLULOSE PRODUCTS (15-28-810 et seq.)
ARTICLE XVIII. NITROCELLULOSE (15-28-940 et seq.)
ARTICLE XIX. MOTION PICTURE TRIAL EXHIBITION ROOMS (15-28-1000 et seq.)
ARTICLE XX. HAZARDOUS DUSTS (15-28-1050 et seq.)
ARTICLE XXI. UNDERGROUND STORAGE TANK VIOLATIONS. (15-28-1220 et seq.)
Subdivision 421 - Special Detailed Requirements
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
15-28-530  Ventilation.
   Every highly flammable material storage room and every picker or shredder room shall be provided with one or more windows, skylights or other ventilating opening facing a public way, private alley, yard or other open space not less than 15 feet wide, with closures arranged to open for natural ventilation and having a combined area of not less than five percent of the total wall area of the room. The required combined area of openings which are arranged to open for ventilation shall be provided with sashes or dampers, or other closures which shall be hung overbalanced and held in place in such manner that an explosion or fire within the room will cause such sash, damper or closure to open for its full area; provided, however, that in lieu of such requirements it shall be permissible to provide a vent flue or flues extending directly to the outside air, which shall be used solely for the purposes of ventilating such room, which shall have a combined area of not less than five percent of the total wall area of the room, with an inclosure of the same fire-resistive value as is required for the inclosures of the room, and equipped with a normally closed noncombustible trap door arranged to open automatically in case of explosion or fire within the room. No such window, skylight, ventilating opening or vent flue required by this section shall be nearer than four feet, six inches to any other building or structure on the same premises or to any interior lot line.
(Prior code §  92-42)
15-28-540  Fire protection equipment.
   Where a supply of steam at not less than five pounds pressure is available, a steam jet shall be installed in every picker or shredder room with a control valve outside of the room. Where such a supply of steam is not available, a standard two and one-half gallon fire extinguisher shall be kept outside the entrance door to every such room and adjacent thereto, with an opening 12 inches square provided through the inclosure of the room, through which the nozzle of the extinguisher may be directed into the room. Such opening shall be provided with a noncombustible cover, removable from the outside.
(Prior code §  92-43)
15-28-550  Instructions.
   Every valve required for the control of the discharge of steam through a steam jet in a picker or shredder room, shall be marked with a metal sign which shall bear the words “STEAM FIRE LINE”. Every such sign shall meet the requirements of Section 15-28-120 for lettering.
(Prior code §  92-44)
15-28-560  Heating.
   In every picker or shredder room, all heating shall be by steam or hot water radiation equipped with guards as provided for a standard drying room.
(Prior code §  92-45)
15-28-570  General construction requirements.
   A highly flammable material storage building may be of any type of construction permitted under the provisions of this Code for a storage unit.
(Prior code §  92-46)
15-28-580  Danger signs.
   Every building or room for the use or storage of highly flammable materials, shall have the words “FLAMMABLE – KEEP FIRE AWAY” painted in a conspicuous position on the outside thereof. Such wording shall be in plainly legible bright red letters on a white background with letters not less than six inches high and with the principal strokes thereof not less than three-fourths inch in width.
(Prior code §  92-47)