13-116-020  Prohibited types of construction.
   Except as otherwise provided in Section 13-116-130, no building or structure of Type II or Type IV construction shall be erected within the fire limits, as defined in Section 13-116-010 nor shall wood or other combustible veneers be permitted on building or structures within such limits.
(Prior code § 50-2)
13-116-030  Projections beyond main building walls.
   Eaves, cornices, ornamental projections, chimneys, buttresses, etc., shall not project beyond main building walls more than one-third of the distance to interior lot lines.
(Prior code § 50-3)
13-116-040  Types IV-A and IV-B buildings – Location.
   Buildings of Type IV-A and IV-B construction, when permitted, shall be located not less than six feet from interior lot lines and not less than 12 feet from any other building on the same lot with the following exceptions:
   (a)   A private garage may be located in accordance with Section 13-96-280.
   (b)   Any building except private detached garages, having exterior wall construction providing fire resistance of not less than one hour may be located not less than three feet from an interior lot line and not less than six feet from another building on the same lot.
(Prior code § 50-4; Amend Coun. J. 10-28-97, p. 54731)
13-116-050  Type II buildings – Location.
   Buildings of Type II construction, when permitted, shall be located not less than three feet from an interior lot line and not less than six feet from another building on the same lot unless the wall facing such lot line or adjoining building is constructed of materials providing fire resistance of not less than two hours and with all openings protected as required in Section 15-8-110.
(Prior code § 50-5)
13-116-060  Frontage requirements.
   Every building or structure, except accessory buildings, shall front on a street or public way not less than 30 feet wide or shall have access to such a street or public way by means of an unobstructed open area not less than ten feet wide.
(Prior code § 50-6)
13-116-070  Zoning.
   Nothing in this chapter shall be interpreted to prevent the application of location limitations required by the Chicago Zoning Ordinance.
(Prior code § 50-7)
13-116-080  Height limitations.
   Within the fire limits no building or structure of wood frame construction or of unprotected noncombustible construction shall be increased in height.
(Prior code § 50-8)
13-116-090  Building extensions.
   Within the fire limits no building or structure shall be extended on any side by wood frame construction or unprotected noncombustible construction. When extensions are made to a building or structure of wood frame construction or unprotected noncombustible construction, the aggregate area of the building or structure including the extension shall not exceed the allowable area for wood frame construction in either Table 13-48-070 codified in Section 13-48-070 or Table 13-48-080 codified in Section 13-48-080.
(Prior code § 50-9)
13-116-100  Occupancy change.
   Nothing in this section shall be construed to prohibit other alterations within the fire limits; provided, there is no change of occupancy to a class of occupancy otherwise prohibited.
(Prior code § 50-10)
13-116-110  Moving of buildings.
   No building or structure of wood frame construction or unprotected noncombustible construction shall be moved from without to within the fire limits or from one lot to another within the fire limits.
(Prior code § 50-11)