Delete Table R302.6 Dwelling-Garage Separation and replace with the following Table:
TABLE R302.6 DWELLING-GARAGE SEPARATION
Separation | Material |
From the residence, attics, and habitable rooms above the garage | Not less than 5/8-inch Type X gypsum board or equivalent applied to the garage side |
Structure(s) supporting floor/ceiling assemblies used for separation required by this section | Not less than 5/8-inch Type X gypsum board or equivalent applied to the garage side |
Garages located less than 3 feet from a dwelling unit on the same lot | Not less than 5/8-inch Type X gypsum board or equivalent applied to the interior side of the exterior walls that are within this area |
(Ord. 3-25, 2-4-2025)
Repeal section R303.4 and replace with the following:
R303.4 Mechanical ventilation. Dwelling units shall be provided with whole-house mechanical ventilation in accordance with Section M1505.4.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 40-20, 12-1-2020, eff. 1-1-2021)
R309.3 Flood Hazard Areas. All construction within flood hazard areas shall be designed and constructed in accordance with the Flood Hazard regulations of the Boise Development Code in addition to this code. For buildings located in flood hazard areas as established by Table R301.2(1), garage floors shall be:
1. Elevated to or above the design flood elevation as determined in accordance with Section R322; or
2. Located below the design flood elevation provided that the floors are at or above grade on not less than one side, are used solely for parking, building access, or storage, meet the requirements of Section R322 and are otherwise constructed in accordance with this code.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 40-20, 12-1-2020, eff. 1-1-2021)
The exception to section R313.1 shall be modified as follows:
Exception. Automatic residential fire sprinkler systems shall not be required in townhouses where either two (2) 1-hour fire-resistance rated walls or a common two-hour fire-resistance rated wall, as specified in item number 2 of section R302.2.2, is installed between dwelling units or when additions or alterations are made to existing townhouses that do not have an automatic residential fire sprinkler system installed.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 40-20, 12-1-2020, eff. 1-1-2021)
R313.2 One- And Two-Family Dwellings Automatic Fire Sprinkler Systems, is deleted.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 40-20, 12-1-2020, eff. 1-1-2021)