Disinfection and Chemicals Readings
Pool Class
A
B
C
D
REQUIREMENTS TABLE
Disinfection and Chemicals Readings
Pool Class
A
B
C
D
Chlorine, Free, ppm
   STABILIZED (Cyanurate)
   Minimum
1.0
1.0
1.5
1.5
   Maximum
4.0
4.0
4.0
4.0
   UNSTABILIZED
   Minimum
.4
.4
.6
.6
   Maximum
1.5
1.5
1.5
1.5
Bromine, Total, ppm
   Minimum
2.0
2.0
2.0
2.0
   Maximum
6.0
6.0
6.0
6.0
Closure Required When Readings Fall Below Minimum Listed Above
Free and Total Chlorine
   Maximum
.4
.4
.4
.4
pH
   Minimum
7.2
7.2
7.2
7.2
   Maximum
8.0
8.0
8.0
8.0
   Closure Below
7.0
7.0
7.0
7.0
   Closure Above
8.2
8.2
8.2
8.2
Cyanuric Acid, ppm
   Maximum
100
100
100
100
Complete Circulation of all Water Within
6 hours
6 hours
2 hour
1 hour
Bather Load
   Diving Board (each) Allowance
300 ft.
300 ft.
N/A
N/A
   Person Capacity
1/25ft2
1/25ft2
1/25ft2
1/10ft2
Total Dissolved Solids, All Classes
3,000 ppm or 2,000 ppm Over Naturally Occurring Whichever Is Less
Total Alkalinity, All Classes
80 - 125 ppm
Calcium Hardness, All Classes
125 - 400 ppm