1749.04 PERMANENTLY INSTALLED CENTRAL AIR CONDITIONING UNITS.
   Permanently installed residential central air conditioning units, installed after the date of passage of this section, shall be placed at the rear of the house in between the side house lines, but not less than ten feet from any side property line.
(Ord. 42-1993. Passed 3-15-93.)
1749.05 PORTABLE TOILETS.
   (a)   Placement and Uses. The placement and use of self-contained portable toilet units may be permitted on private property only under the following conditions:
      (1)   Industrial and agricultural uses. Portable toilets must be set back from all property lines and street rights-of-way a minimum of 100 feet and in no case shall they be located in front of the Use District setback line.
      (2)   Residential uses.
         A.   Occupied residential dwelling units. An “event” shall consist of the delivery and pick-up of the portable toilet unit. Use of self-contained portable toilet units in conjunction with occupied residences are limited to temporary events a maximum of seven calendar days per event with a maximum of four events per calendar year and at least one month in between events.
         B.   During construction or remodeling. Use of self contained portable toilet units in conjunction with construction or remodeling of residential dwelling units shall be limited to a service period of 30 days.
         C.   Location standards related to residential construction sites. Portable toilet units must be placed on the rear half of the lot no less than 40 feet from any other occupied structure.
      (3)   Commercial uses. Portable toilet units must be placed within work barricade areas and in a location approved by the Building Inspector no less than 40 feet from occupied structures and street rights-of-way.
(Ord. 202-2007. Passed 10-15-07.)
1749.06 SHALLOW FOUNDATIONS.
   Structures that are not attached to the dwelling that are of wood or steel platform framed construction are permitted to have foundations that extend to not less than 18 inches in depth below finished grade, provided all of the following apply:
   (a)   The maximum dimension of the structure does not exceed 24 feet in length or width.
   (b)   The maximum height of the structure does not exceed 15 feet when measured to the highest point of the roof.
   (c)   The structure is located a minimum distance of ten feet from the dwelling it serves.
   (d)   The foundation bears upon soil capable of supporting all imposed loads.
   (e)   The foundation is constructed of solid concrete poured at least 12 inches wide continuously around the perimeter of the structure.
   (f)   The foundation is poured monolithically with a minimum four-inch nominally thick concrete floor slab that is reinforced with steel mesh weighing not less than 40 pounds per 100 square feet or equivalent reinforcement that is turned down continuously into the footing.
   (g)   No sheds, porches or other structures are attached increasing the structure's length or width beyond 24 feet or height beyond 15 feet.
   (h)   A six-inch wide concrete curb is constructed around the perimeter of the structure that is a minimum of eight inches above the adjoining grade.
(Ord. 91-2009. Passed 4-20-09.)