Zoning District | Land Use | MINIMUM ZONING LOT REQUIREMENTS | BUILDING REQUIREMENTS | Land Uses | ||||||
Yard (Feet) | ||||||||||
Mini- mum Size | Permitted | Size | Frontage (feet) | Front | One Side | 2 Sides | Rear | Minimum Floor Area Per Dwelling Unit Square Feet | Max. Height (Ft.) | Conditionally Permitted 2 |
5 acres | 1. Three to four-family dwellings 1/ | 10,890 sq. ft. per dwell- ing unit 1/ | 150 | 40 | 15 | 30 | 30 | Two bedrooms: 1200 Three or more bedrooms: 1500 | 35 | 1. Home occupations |
2. Two- family dwelling | 24,000 sq. ft. | 100 | 30 | 10 | 25 | 30 | Ground floor with basement: 1100 One story without basement: 1200 More than one story: 1500 | 35 | 2. Small wind energy systems | |
3. Single- family dwelling | 12,000 sq. ft. | 90 | 30 | 8 | 20 | 30 | Ground floor with basement: 1200 One story without basement: 1400 More than one story: 1500 | 35 | ||
4. Parkland & open space | 1 acre | 150 | 40 | 20 | 40 | 50 | None | 35 |
NOTES - Parking and/or loading shall be provided in accordance with the requirements specified in Chapter 1161. Where the R-5 District is within the area of jurisdiction of the D-Design Area or Historical Preservation Area, no building or structure shall be constructed, enlarged, converted, structurally altered or reconstructed, nor shall any building or structure be moved onto any lot within the D-Design Area or Historical Preservation Area except as provided in Chapter 1129.
1/ Subject to the review and approval of the development plan for the project in accordance with the requirements specified in Chapter 1153.