All doors providing access to interior corridors or stairs in occupancy groups R-1 and R-2 shall be equipped with a device that will ensure the door, when opened and released, returns to the closed position and self-latches shut by July 31, 2021.
(L.L. 2018/111, 6/9/2018, eff. 6/9/2018; Am. L.L. 2022/063, 6/1/2022, eff. 7/16/2022 and 11/7/2022)
By July 1, 2021, existing buildings equipped with a fire alarm system and that contain group A-1, A-2 or A-3, Group B or Group M occupancies shall comply with the retroactive requirements of section 915.1.2.1 of the New York city building code.
(L.L. 2018/191, 12/1/2018, eff. 8/28/2019; L.L. 2021/013, 1/17/2021, retro. eff. 1/1/2021; Am. L.L. 2021/126, 11/7/2021, eff. 11/7/2022)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2021/126.
Where concealed existing piping is exposed in the course of the alteration or repair of a building, the owner of the building shall provide for the insulation of the exposed piping. The exposed piping shall be insulated to the extent required by the New York city energy conservation code for newly installed pipe of the same specifications and serving the same function as the exposed pipe. The entire exposed length of the piping shall be insulated as well as any further length of concealed pipe that can be directly accessed through openings made in the course of such alteration or repair.
Exceptions:
1. Exposed pipe with 1 inch (25 mm) thick continuous coverage of existing insulation in good condition.
2. Where the length of concealed pipe which may be directly accessed through openings made in the course of such alteration or repair is less than three feet (914 mm).
3. Where there is not sufficient space to insulate pipes to the extent required by the New York city energy conservation code due to conflicts with existing construction, pipes shall be insulated to the extent that space allows.
(Am. L.L. 2021/126, 11/7/2021, eff. 11/7/2022)
Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2014/012 and L.L. 2021/126.