Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
CHAPTER 14X-5
FIRE SAFETY REQUIREMENTS
14X-5-501   General.
14X-5-502   Fire and smoke protection features.
14X-5-503   Reserved.
14X-5-504   Fire protection and life safety systems.
14X-5-505   Means of egress.
14X-5-506   Life safety compliance plan.
14X-5-501 GENERAL.
14X-5-501.1 Scope.
This chapter provides minimum standards for fire safety and fire protection systems in existing structures and outdoor areas.
14X-5-501.2 Required construction.
Existing buildings must comply with not less than the minimum provisions specified in Table 14X-5-501.2. The provisions of this chapter do not allow the elimination of fire protection systems or a reduction in the level of fire safety provided in existing structures constructed in accordance with requirements in effect at the time of construction.
Exceptions:
1.   Where an alteration has been permitted in accordance with the Chicago Building Rehabilitation Code.
2.   Group U occupancies.
Table 14X-5-501.2 Occupancy- and Use-Based Requirements a
SECTION
USE
OCCUPANCY CLASSIFICATION
High-rise
Atrium
A
B
E
F
H-1
H-2
H-3
H-4
H-5
I-1
I-2
I-3
I-4
M
R-1
R-2
R-3
R-4
R-5
S
SECTION
USE
OCCUPANCY CLASSIFICATION
High-rise
Atrium
A
B
E
F
H-1
H-2
H-3
H-4
H-5
I-1
I-2
I-3
I-4
M
R-1
R-2
R-3
R-4
R-5
S
502.2
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
502.3
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
502.4
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
502.5
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
502.6
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
502.7.1
R
502.7.2
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
502.7.3
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
502.7.4
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
502.7.5
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
502.7.6
R
R
502.8
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
502.9
R
504.1
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
504.2.1
R
504.2.2
R
504.2.3
R
504.2.4
R
504.2.5
R
R
504.2.6
R
504.2.7
R
R
504.2.8
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
504.2.9
R
504.3.1
R
504.3.2
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
504.3.3
R
504.4.1
R
504.4.2
R
504.4.3
R
R
R
R
504.4.4
R
504.5
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
504.6.1
R
504.6.2
R
504.6.3
R
R
R
R
504.6.4
R
R
R
504.6.5
R
R
R
R
504.6.6
R
504.6.7
R
504.7
R
504.8
R
R
R
R
R
R
504.9
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
505
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
506
R
 
R =   The building is required to comply.
a.   Existing buildings must comply with the sections identified as "Required" based on occupancy classification or use, or both, whichever is applicable.
(Amend Coun. J. 2-19-20, p. 14473, Art. V, § 17)
14X-5-501.3 Historic buildings.
Historic buildings may develop a fire protection plan in accordance with NFPA 914 and provide alternative means of fire safety where approved by the building official or fire code official.
(Amend Coun. J. 2-19-20, p. 14473, Art. V, § 18)
14X-5-502 FIRE AND SMOKE PROTECTION FEATURES.
14X-5-502.1 Scope.
This section governs maintenance of the materials, systems, and assemblies used for structural fire resistance and fire- resistance-rated construction, separation of adjacent spaces to safeguard against the spread of fire and smoke within a structure, and the spread of fire to or from separate structures.