Loading...
Open sides of a stair, landing, balcony, porch, deck, ramp, or other walking surface that is more than 30 inches (762 mm) above the floor or ground immediately below must have guards. Existing guards must be not less than 30 inches (762 mm) in height above the floor of the landing, balcony, porch, deck, ramp, or other walking surface. Existing guards must be not less than 36 inches (914 mm) in height where the walking surface is more than 12 feet (3658 mm) above the floor or ground immediately below.
Exceptions:
1. Guards are not required in existing buildings where not required for new construction by the Chicago Building Code.
2. Open sides of a stairway equipped with a handrail on at least one side in accordance with Section 14X-3-306.1, where the walking surface is less than 8 feet (2438 mm) above the floor or ground immediately below.
Guards that are required to be 36 inches (914 mm) in height by Section 14X-3-306.2 must have balusters or ornamental patterns such that a 6-inch (152 mm) diameter sphere cannot pass through any opening up to a height of 34 inches (864 mm).
Exceptions:
1. At elevated walking surfaces provided for access to equipment, openings in guards must not allow passage of a 21-inch (533 mm) diameter sphere.
2. In Group I-3, F, H, and S occupancies, openings in guards must not allow passage of a 21-inch (533 mm) diameter sphere.
3. Approved existing open guards.
Every occupant of a structure must dispose of all rubbish and garbage in a clean and sanitary manner as provided in Chapter 7-28 of the Municipal Code.