Skip to code content (skip section selection)
Compare to:
Chicago Overview
Municipal Code of Chicago
MUNICIPAL CODE OF CHICAGO
TITLE 1 GENERAL PROVISIONS
TITLE 2 CITY GOVERNMENT AND ADMINISTRATION
TITLE 3 REVENUE AND FINANCE
TITLE 4 BUSINESSES, OCCUPATIONS AND CONSUMER PROTECTION
TITLE 5 HOUSING AND ECONOMIC DEVELOPMENT
TITLE 6 HUMAN RIGHTS*
TITLE 7 HEALTH AND SAFETY
TITLE 8 OFFENSES AFFECTING PUBLIC PEACE, MORALS AND WELFARE
TITLE 9 VEHICLES, TRAFFIC AND RAIL TRANSPORTATION
TITLE 10 STREETS, PUBLIC WAYS, PARKS, AIRPORTS AND HARBORS
TITLE 11 UTILITIES AND ENVIRONMENTAL PROTECTION
TITLE 12 RESERVED
TITLE 13 BUILDINGS AND CONSTRUCTION
TITLE 14 RESERVED*
TITLE 14A ADMINISTRATIVE PROVISIONS OF THE CHICAGO CONSTRUCTION CODES*
TITLE 14B BUILDING CODE*
TITLE 14C CONVEYANCE DEVICE CODE*
TITLE 14E ELECTRICAL CODE*
TITLE 14F FIRE PREVENTION CODE*
TITLE 14G FUEL GAS CODE*
TITLE 14M MECHANICAL CODE*
TITLE 14N 2022 ENERGY TRANSFORMATION CODE*
TITLE 14P PLUMBING CODE*
TITLE 14R BUILDING REHABILITATION CODE*
TITLE 14X MINIMUM REQUIREMENTS FOR EXISTING BUILDINGS*
TITLE 15 FIRE PREVENTION
TITLE 16 LAND USE
TITLE 17 CHICAGO ZONING ORDINANCE
TITLE 18 BUILDING INFRASTRUCTURE
APPENDIX TO THE MUNICIPAL CODE OF CHICAGO (RESERVED)*
TABLES
Chicago Zoning Ordinance and Land Use Ordinance
Loading...
14X-3-306.2 Guards.
Open sides of a stair, landing, balcony, porch, deck, ramp, or other walking surface that is more than 30 inches (762 mm) above the floor or ground immediately below must have guards. Existing guards must be not less than 30 inches (762 mm) in height above the floor of the landing, balcony, porch, deck, ramp, or other walking surface. Existing guards must be not less than 36 inches (914 mm) in height where the walking surface is more than 12 feet (3658 mm) above the floor or ground immediately below.
Exceptions:
1.   Guards are not required in existing buildings where not required for new construction by the Chicago Building Code.
2.   Open sides of a stairway equipped with a handrail on at least one side in accordance with Section 14X-3-306.1, where the walking surface is less than 8 feet (2438 mm) above the floor or ground immediately below.
14X-3-306.2.1 Opening limitation.
Guards that are required to be 36 inches (914 mm) in height by Section 14X-3-306.2 must have balusters or ornamental patterns such that a 6-inch (152 mm) diameter sphere cannot pass through any opening up to a height of 34 inches (864 mm).
Exceptions:
1.   At elevated walking surfaces provided for access to equipment, openings in guards must not allow passage of a 21-inch (533 mm) diameter sphere.
2.   In Group I-3, F, H, and S occupancies, openings in guards must not allow passage of a 21-inch (533 mm) diameter sphere.
3.   Approved existing open guards.
14X-3-306.3 Additional requirements.
Handrails and guards must also meet all applicable requirements that were in effect at the time the flight of stairs or walking surface was constructed.
14X-3-307 RUBBISH AND GARBAGE.
14X-3-307.1 Accumulation of rubbish or garbage.
Outdoor areas and the interior of structures must be kept free from the accumulation of rubbish and garbage. Unless specifically allowed by the Chicago Zoning Ordinance, outdoor areas may not be used for the storage of inoperable motor vehicles.
14X-3-307.2 Disposal of rubbish and garbage.
Every occupant of a structure must dispose of all rubbish and garbage in a clean and sanitary manner as provided in Chapter 7-28 of the Municipal Code.
14X-3-308 PEST MANAGEMENT.
Loading...