Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
Subdivision 403 - High-Rise buildings
Subdivision 406 - Motor-Vehicle-Related Occupancies
Subdivision 407 - Special Institutional
Subdivision 411 - Special Amusement Buildings
Subdivision 413 - Combustible Storage
Subdivision 414 - Hazardous Materials
CHAPTER 4-108 FILLING STATIONS
CHAPTER 4-115 RESERVED*
CHAPTER 15-20 EXPLOSIVES AND FIREWORKS
CHAPTER 15-24 FLAMMABLE LIQUIDS
CHAPTER 15-26 FUME AND FLAMMABLE COMPRESSED GASES
CHAPTER 15-28 HAZARDOUS MATERIALS AND COMBUSTIBLE SOLIDS
Subdivision 421 - Special Detailed Requirements
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
15-24-1020  Brakes.
   Every trailer or semitrailer shall be equipped with a reliable system of brakes and adequate provision shall be made for its efficient operation from the driver's seat of the vehicle drawing such trailer or semitrailer.
(Prior code §  129.1-93)
15-24-1030  Grounding.
   Tank, chassis, axles and springs shall be electrically interconnected for static electricity control. In addition, adequate provisions shall be made for bonding the container being filled to the tank, chassis, axles and springs.
(Prior code §  129.1-94)
15-24-1040  Lighting.
   Tank trucks, tank trailers and semitrailers shall be equipped with artificial lighting, conforming to the requirements of the state regulations. Lighting circuits shall have suitable over-current protection such as fuses or automatic circuit breakers. The wiring shall be of ample carrying capacity and mechanical strength and shall be substantially secured, insulated and protected against damage. No lighting other than electric lighting shall be permitted on any tank truck, tank trailer or tank semitrailer. Every tank trailer and tank semitrailer shall be provided with side lights and a taillight or lights.
(Prior code §  129.1-95)
15-24-1050  Fire extinguishers.
   Each tank truck, tank trailer and semitrailer shall be equipped and maintained with at least one hand fire extinguisher of a type suitable for extinguishing flammable liquid fires. Fire extinguishers shall be kept in good operating condition at all times and shall be located in an accessible place on such tank vehicles.
(Prior code §  129.1-96)
15-24-1060  Exhaust systems.
   The exhaust system, including muffler and exhaust line, shall have not less than 12 inches clearance from the fuel system and any combustible material, and shall not be exposed to accumulations of grease or oil, nor to leakage of fuel from faults in the fuel system or from careless filling of fuel tanks. No muffler cutouts shall be permitted.
(Prior code §  129.1-97)
15-24-1070  Warning signs.
   Every tank motor vehicle used for the transportation of flammable liquids shall have the word “FLAMMABLE” displayed in English on both sides and rear of the tank in letters not less than five inches high by at least a one-inch stroke, and on the front bumper in letters not less than four inches high by at least a one-inch stroke, each on a background of sharply contrasting color, except that the lettering on vehicles used exclusively for local distribution need not exceed five inches in height by at least a three-fourths inch stroke.
(Prior code §  129.1-98)
15-24-1080  DOT approved trucks.
   Any tank truck, tank trailer or semitrailer constructed in accordance with the Department of Transportation regulations shall be deemed to be in compliance with the regulations given in Section 15-24-1090 of this Code.
(Prior code §  129.1-98.1)
Loading...