Skylights in greenhouses shall comply with the requirements of Section 15-8-520 with the following exceptions:
(a) Wire glass shall not be required.
(b) Skylights of greenhouses not exceeding one story or 20 feet in height, nor 3,000 square feet in area, may be constructed of combustible materials.
(Prior code § 61-16.3)
ARTICLE XVI. TEMPORARY PLATFORMS (13-96-610 et seq.)
Platforms, erected for temporary use in any assembly or open air assembly unit under the provisions of Section 13-32-170, shall comply with the following requirements.
(a) Height and Area.
(1) The height of a temporary platform shall not exceed six feet above the floor or ground level.
(2) No temporary platform shall exceed 1,500 square feet in area.
(b) Construction.
(1) Platforms may be constructed of materials not more combustible than wood.
(2) Platforms shall be designed to support a uniform live load of not less than 100 pounds per square foot and shall be securely braced for lateral stiffness.
(Prior code § 61-17)
ARTICLE XVII. PRIVATE RESIDENTIAL SWIMMING POOLS (13-96-620 et seq.)
(Prior code § 61-18)