Skip to code content (skip section selection)
Compare to:
Boise Overview
Boise, ID Code of Ordinances
CITY CODE of BOISE CITY, IDAHO
ORDINANCES PENDING REVIEW FOR CODIFICATION
ADOPTING ORDINANCE
TITLE 1 ADMINISTRATION
TITLE 2 BOARDS, COMMISSIONS, COMMITTEES
TITLE 3 LICENSES AND PERMITS
TITLE 4 HEALTH AND SANITATION
TITLE 5 PUBLIC SAFETY
CHAPTER 1 ANIMALS
CHAPTER 2 GENERAL OFFENSES
CHAPTER 3 OFFENSES AGAINST PUBLIC OR PRIVATE PROPERTY
CHAPTER 4 WEAPONS AND FIREARMS
CHAPTER 5 MINORS
CHAPTER 6 PUBLIC NUDITY
CHAPTER 7 NOISE CONTROL
CHAPTER 8 ASSEMBLAGES
CHAPTER 9 LITTERING
CHAPTER 10 FALSE SECURITY ALARMS
CHAPTER 11 SMOKE FREE AIR
CHAPTER 12 FIRE PREVENTION CODE
5-12-1: DECLARATION OF INTENT:
5-12-2: CODE ADOPTED:
5-12-3: IFC AMENDMENT, SECTION 101.1, TITLE:
5-12-4: IFC AMENDMENT, SECTION 103.3, DEPUTIES:
5-12-5: IFC AMENDMENT, ADD SECTION 104.2.1, FIRE DEPARTMENT PLAN REVIEW:
5-12-6: IFC AMENDMENT, SECTION 105.2.3, TIME LIMITATION OF APPLICATION:
5-12-7: IFC AMENDMENT, SECTION 105.3.2, EXTENSIONS:
5-12-8: IFC AMENDMENT, SECTION 105.3.3, OCCUPANCY PROHIBITED BEFORE APPROVAL:
5-12-9: IFC AMENDMENT, ADD SECTION 106.6, RE- REVIEW FEE:
5-12-10: IFC AMENDMENT, ADD SECTION 106.7, FIRE PROTECTION SYSTEM PLAN MODIFICATION FEE:
5-12-11: IFC AMENDMENT, ADD SECTION 106.8, REINSPECTION FEES:
5-12-12: IFC AMENDMENT, SECTION 109.1, BOARD OF APPEALS ESTABLISHED:
5-12-13: IFC AMENDMENT, SECTION 110.4, VIOLATION PENALTIES:
5-12-14: IFC AMENDMENT, SECTION 112.4, FAILURE TO COMPLY:
5-12-15: IFC AMENDMENT, SECTION 202, GENERAL DEFINITIONS:
5-12-16: IFC AMENDMENT, SECTION 304.1.2, VEGETATION:
5-12-17: IFC AMENDMENT, SECTION 307.2, PERMIT REQUIRED:
5-12-18: IFC AMENDMENT, SECTION 307.2.2, AIR QUALITY INDEX:
5-12-19: IFC AMENDMENT, ADD SECTION 315.3.5, STORAGE HEIGHT SIGNAGE:
5-12-20: IFC AMENDMENT, ADD SECTION 401.8.1, SILENCING FIRE ALARMS:
5-12-21: IFC AMENDMENT, SECTION 503.1.1, BUILDINGS AND FACILITIES:
5-12-22: IFC AMENDMENT, SECTION 503.2.4, TURNING RADIUS:
5-12-23: IFC AMENDMENT, SECTION 503.2.6, BRIDGES AND ELEVATED SURFACES:
5-12-24: IFC AMENDMENT, ADD SECTION 503.3.1, SIGNAGE:
5-12-25: IFC AMENDMENT, ADD SECTION 503.5.2, BARRICADE SPECIFICATIONS:
5-12-26: IFC AMENDMENT, ADD SECTION 503.7, DIVE BOAT ACCESS:
5-12-27: IFC AMENDMENT, ADD SECTION 505.1.1, CORNER LOTS:
5-12-28: IFC AMENDMENT, ADD SECTION 505.1.2, TENANT SPACE IDENTIFICATION:
5-12-29: IFC AMENDMENT, ADD SECTION 505.1.3, ADDRESSES FOR MULTIFAMILY DWELLINGS:
5-12-30: IFC AMENDMENT, SECTION 506.1, KEY BOXES WHERE REQUIRED:
5-12-31: IFC AMENDMENT, SECTION 507.2, TYPE OF WATER SUPPLY:
5-12-32: IFC AMENDMENT, SECTION 507.5.1, FIRE HYDRANT SYSTEMS WHERE REQUIRED:
5-12-33: IFC AMENDMENT, ADD SECTION 507.5.7, FIRE HYDRANT SUPPLY CONNECTIONS:
5-12-34: IFC AMENDMENT, SECTION 701.6, OWNER’S RESPONSIBILITY:
5-12-35: IFC AMENDMENT, ADD SECTION 901.4.2.1, NON- REQUIRED FIRE ALARM SYSTEMS:
5-12-36: IFC AMENDMENT, ADD SECTION 903.3.1.1.3, SPECULATIVE WAREHOUSE:
5-12-37: IFC AMENDMENT, ADD SECTION 903.3.1.3.1, NFPA 13D ALARMS:
5-12-38: IFC AMENDMENT, ADD SECTION 903.3.5.3, CONTROL VALVE LOCATION:
5-12-39: IFC AMENDMENT, ADD SECTION 903.3.5.4, DEPTH OF COVER:
5-12-40: IFC AMENDMENT, SECTION 903.4.3, FLOOR CONTROL ASSEMBLY:
5-12-41: IFC AMENDMENT, ADD SECTION 904.7.2, USE OF FOAM-WATER SUPPRESSION SYSTEMS:
5-12-42: IFC AMENDMENT, ADD SECTION 906.5.1, MULTI- STORY INSTALLATION NEAR STAIRWELLS:
5-12-43: IFC AMENDMENT, ADD SECTION 907.6.6.3, SINGLE COMMUNICATION PATH MONITORING SYSTEMS:
5-12-44: IFC AMENDMENT, ADD SECTION 907.6.7, FACP LOCATION AND IDENTIFICATION:
5-12-45: IFC AMENDMENT, ADD SECTION 912.2.3, DISTANCE TO ACCESS AND WATER SUPPLY:
5-12-46: IFC AMENDMENT, SECTION 914.3.1.2, WATER SUPPLY TO REQUIRED FIRE PUMPS:
5-12-47: IFC AMENDMENT, ADD SECTION 914.8.3.3, USE OF FOAM SYSTEMS IN AIRCRAFT HANGARS:
5-12-48: IFC AMENDMENT, SECTION 1101.1, SCOPE:
5-12-49: IFC AMENDMENT, SECTION 2007.6, FOAM PROTECTION:
5-12-50: IFC AMENDMENT, SECTION 3304.5, FIRE WATCH:
5-12-51: IFC AMENDMENT, ADD SECTION 3304.9, FIRE SAFETY REQUIREMENTS FOR BUILDINGS OF TYPES IV-A, IV-B, AND IV-C CONSTRUCTION:
5-12-52: IFC AMENDMENT, ADD CHAPTER 40, CHILDCARE FACILITIES:
5-12-53: IFC AMENDMENT, ADD CHAPTER 41, WILDLAND- URBAN INTERFACE (WUI) CODE:
5-12-54: IFC AMENDMENT, SECTION 5601.1.3, FIREWORKS:
5-12-55: IFC AMENDMENT, SECTION 5609, FIREWORKS SALES AND USE:
5-12-56: IFC AMENDMENT, CHAPTER 80, REFERENCED STANDARDS:
5-12-57: IFC AMENDMENT, ADOPT APPENDIX B, FIRE-FLOW REQUIREMENTS FOR BUILDINGS:
5-12-58: IFC AMENDMENT, APPENDIX B, SECTION B104.2, AREA SEPARATION, ADD EXCEPTION:
5-12-59: IFC AMENDMENT, ADOPT APPENDIX C, FIRE HYDRANT LOCATIONS AND DISTRIBUTION:
5-12-60: IFC AMENDMENT, ADOPT APPENDIX D, FIRE APPARATUS ACCESS ROADS:
5-12-61: IFC AMENDMENT, AMEND SECTION D103.2, GRADE:
5-12-62: IFC AMENDMENT, AMEND SECTION D103.5, FIRE APPARATUS ACCESS ROAD GATES:
5-12-63: IFC AMENDMENT, D107.1, ONE- OR TWO-FAMILY DWELLING RESIDENTIAL DEVELOPMENTS:
5-12-64: IFC AMENDMENT, ADOPT APPENDIX F, HAZARD RANKING:
5-12-65: IFC AMENDMENT, ADOPT APPENDIX L, REQUIREMENTS FOR FIRE FIGHTER AIR REPLENISHMENT SYSTEMS:
5-12-66: IFC AMENDMENT, APPENDIX L, L101.1, SCOPE:
5-12-67: IFC AMENDMENT, CHAPTER 42, REQUIREMENTS FOR STORAGE, MANUFACTURING, OR USAGE OF LITHIUM METAL AND LITHIUM-ION BATTERIES:
CHAPTER 13 PUBLIC SAFETY EMERGENCY RESPONSE COST RECOVERY
CHAPTER 14 LOST, ABANDONED, UNCLAIMED PERSONAL PROPERTY
CHAPTER 15 DISCRIMINATION PROHIBITED
CHAPTER 16 RESIDENTIAL RENTAL APPLICATION FEES - REQUIREMENTS AND PROHIBITIONS
CHAPTER 17 TENANT PROTECTIONS
TITLE 6 MOTOR VEHICLES AND TRAFFIC
TITLE 7 PUBLIC WAYS AND PROPERTY
TITLE 8 AIRPORT
TITLE 9 BUILDING CODES AND REGULATIONS
TITLE 10 PUBLIC UTILITIES
TITLE 11 DEVELOPMENT CODE
PARALLEL REFERENCES
Loading...
5-12-45: IFC AMENDMENT, ADD SECTION 912.2.3, DISTANCE TO ACCESS AND WATER SUPPLY:
   912.2.3 Distance to Access and Water Supply. Fire department connections (FDC's) and associated outside alarm indicator shall be installed within 100 feet of an approved fire apparatus access lane and within 300 feet of a fire hydrant.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021)
5-12-46: IFC AMENDMENT, SECTION 914.3.1.2, WATER SUPPLY TO REQUIRED FIRE PUMPS:
   914.3.1.2 Water supply to required fire pumps. In all buildings that are more than 420 feet (128 m) in building height, and buildings of Type IV-A and IV-B construction that are more than 120 feet (36.6 m) in building height, required fire pumps shall be supplied by connections to not fewer than two water mains located in different streets. Separate supply piping shall be provided between each connection to the water main and the pumps. Each connection and the supply piping between the connection and the pumps shall be sized to supply the flow and pressure required for the pumps to operate.
      Exception: Two connections to the same main shall be permitted provided that the main is valved such that an interruption can be isolated so that the water supply will continue without interruption through not fewer than one of the connections.
(Ord. 50-21, 11-30-2021, eff. 1-1-2022)
5-12-47: IFC AMENDMENT, ADD SECTION 914.8.3.3, USE OF FOAM SYSTEMS IN AIRCRAFT HANGARS:
   914.8.3.3 Use of Foam Systems in Aircraft Hangars
   Only UL listed flourine-free foam shall be used for the installation or modification of a foam-water suppression system. Proper disposal shall be provided for the flourine foam being replaced as approved by the fire code official.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021; amd. Ord. 7-25, 2-25-2025)
5-12-48: IFC AMENDMENT, SECTION 1101.1, SCOPE:
   1101.1 Scope. The provisions of this chapter shall apply to existing buildings constructed prior to the adoption of this code, if in the opinion of the fire code official they constitute a distinct hazard to life or property.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021)
5-12-49: IFC AMENDMENT, SECTION 2007.6, FOAM PROTECTION:
   Section 2007.6 Foam Protection. Add a paragraph to the end of 2007.6 to read as follows: Prior to the approval of any permit for the installation or modification of a foam-water suppression system, approval in writing shall be received from the fire code official. Approval shall only be permitted when in the opinion of the fire code official no reasonable alternative to these systems exist. Where permitted, mitigation measures shall be provided as approved by the fire code official.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021)
5-12-50: IFC AMENDMENT, SECTION 3304.5, FIRE WATCH:
3304.5 Fire Watch. Add a paragraph to the end of 3304.5 to read as follows:
   Where approved by the fire code official, a fire watch may be used to permit the temporary occupancy of a building before it is completed or during demolition.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021)
5-12-51: IFC AMENDMENT, ADD SECTION 3304.9, FIRE SAFETY REQUIREMENTS FOR BUILDINGS OF TYPES IV-A, IV-B, AND IV-C CONSTRUCTION:
   3304.9 Fire safety requirements for buildings of Types IV-A, IV-B and IV-C construction. Buildings of Types IV-A, IV-B and IV-C construction designed to be greater than six stories above grade plane shall comply with the following requirements during construction unless otherwise approved by the fire code official.
      1.   Standpipes shall be provided in accordance with Section 3314.
      2.   A water supply for fire department operations, as approved by the fire code official and the fire chief.
      3.   Where building construction exceeds six stories above grade plane and noncombustible protection is required by Section 602.4 of the International Building Code, at least one layer of noncombustible protection shall be installed on all building elements on floor levels, including mezzanines, more than four levels below active mass timber construction before additional floor levels can be erected.
         Exception: Shafts and vertical exit enclosures shall not be considered part of the active mass timber construction.
      4.   Where building construction exceeds six stories above grade plane, required exterior wall coverings shall be installed on all floor levels, including mezzanines, more than four levels below active mass timber construction before additional floor levels can be erected.
         Exception: Shafts and vertical exit enclosure shall not be considered part of the active mass timber construction.
(Ord. 50-21, 11-30-2021, eff. 1-1-2022)
5-12-52: IFC AMENDMENT, ADD CHAPTER 40, CHILDCARE FACILITIES:
   4001 GENERAL. This chapter shall apply to new and existing childcare facilities including Family Childcare Homes, Group Childcare Homes and Childcare Centers. All other maintenance and construction provisions of this code for general or specific occupancies or hazards shall also apply.
   4002 EXISTING FACILITIES. Childcare facilities legally approved, and in existence prior to adoption of this code, shall comply with the code under which they were approved. Maintenance provisions of this chapter shall apply to existing facilities. Facilities that cease to operate for a period of six (6) months or more, and are seeking a new license, shall be considered a new childcare facility.
   4003 LICENSE AND INSPECTION. Each premise shall be inspected as often as is deemed necessary by the fire code official or the City Clerk. The City Clerk shall inspect, or cause to be inspected, all Family or Group Childcare Homes before granting a license to operate. The fire code official shall inspect, or shall cause to have inspected, all other Childcare facilities before the City Clerk grants a license to operate.
   4004 LOCATION OF FACILITIES. Facilities or portions of facilities located on a story below the level of exit discharge shall have at least two (2) exits which must open directly to the exterior, one (1) of which shall exit directly from the basement to the exterior. Facilities shall not be located more than one (1) story below ground level. Facilities or portions of facilities located on a story above the level of exit discharge shall have at least two (2) exits which must open directly to the exterior and shall be protected with an automatic fire sprinkler system.
   4005 EXITS. Exits in childcare facilities shall comply with the International Fire Code.
      4005.1 Sliding Door. In Family Childcare Homes and Group Childcare Homes, a sliding door is acceptable as a second exit provided there is also a primary entry/exit door meeting the International Residential Code requirements for dwellings.
   4006 SAFETY. Childcare facilities shall meet all of the following safety requirements.
      4006.1 Closet Doors. Every closet door latch shall be such that children can open the door from inside the closet.
      4006.2 Bathroom Doors. Every bathroom door lock shall permit opening of the locked door from outside in the event of an emergency. The opening device shall be readily accessible to the staff.
      4006.3 Receptacle Covers. All electrical outlets not in immediate use shall be provided with receptacle covers or approved safety devices.
      4006.4 Flashlights. Childcare facilities, with an occupant load of less than 50, shall have at least one (1) flashlight immediately available for each member of the staff.
      4006.5 Portable Fire Extinguishers. A minimum of one (1) 2A-10BC portable fire extinguisher shall be provided on each floor of childcare facilities. Travel distance to portable fire extinguishers shall not exceed seventy-five (75) feet.
   4007 SMOKE ALARMS. Smoke alarms shall be installed in the following locations:
      1.   On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of sleeping rooms.
      2.   In each room used for sleeping, lounging or recreation purposes.
      3.   In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.
      4.   At the top and bottom of the stairways and at no greater spacing than 30 feet on center throughout the corridors of all floors.
      Exception: A childcare Facility not provided with sleeping facilities that only provides care for children more than six (6) years of age.
      4007.1 Power Source. In new facilities, required smoke alarms shall receive their primary power from the building wiring, where such wiring is served from a commercial source, and shall be equipped with a battery backup.
   4008 TESTING AND MAINTENANCE. Operators of childcare facilities shall maintain, in working order, all fire and life safety equipment, systems, and facilities. Inspection, testing and maintenance shall be performed in accordance with this section and other provisions of this code.
      4008.1 Monthly. The following items shall be completed monthly:
         1.   Manual fire alarm system test;
         2.   Testing of all smoke alarms;
         3.   Visual inspection of all portable fire extinguishers;
         4.   Testing all emergency lighting and flashlights for proper operation.
      4008.2 Biannual. The following items shall be completed every six (6) months:
         1.   Replace the batteries of all battery powered smoke alarms with new batteries;
         2.   Replace the batteries in all flashlights with new batteries.
      4008.3 Records. A record of all required inspections, tests and repairs shall be kept on the premises and be made available at the time of license inspection.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021)
5-12-53: IFC AMENDMENT, ADD CHAPTER 41, WILDLAND- URBAN INTERFACE (WUI) CODE:
   4101 SCOPE. Upon the effective date of this ordinance, the requirements contained herein shall be applicable to all new structures and additions constructed within City of Boise Wildland-Urban Interface (WUI) areas. The design and construction of new structures within WUI areas shall comply with all the provisions of this chapter along with the current provisions contained within the Boise City Code and Boise City Zoning Code as adopted and periodically amended or updated. Should any provision within this chapter conflict with any other provision of Boise City Code, then the more restrictive shall control.
   4102 AUTHORITY OF THE CODE OFFICIAL. The fire code official or building code official is hereby authorized to enforce the provisions of this chapter. The fire code official may render interpretations of this code and adopt policies and procedures in order to effectuate the implementation and enforcement of the code provisions contained herein. Such interpretations, policies and procedures shall be in accordance with the intent and purpose of this chapter.
   4103 PLANS AND SPECIFICATIONS
      4103.1 Site Plan. In addition to the requirements for plans in the International Building Code, site plans shall include topography, width and percent of grade of access roads, landscape and vegetation details, locations of structures or building envelopes, existing or proposed overhead utilities, occupancy classification of buildings, types of ignition-resistant construction of buildings, structures and their appendages, roof classification of buildings, and site water supply systems. The code official is authorized to waive or modify the requirement for a site plan where the application for permit is for alteration or repair or where otherwise warranted.
      4103.2 Wildfire Safety Plan. Prior to or with a submittal of a preliminary plat or annexation, a Wildfire Safety Plan shall be prepared and submitted to the code official for review and approved as a part of the plans required for a permit. The Wildfire Safety Plan shall be incorporated into the Covenants, Conditions, and Restrictions (CC&Rs) for developments (if established) to ensure implementation, maintenance, and adherence to these requirements.
         4103.2.1 General. When required by the code official, a Wildfire Safety Plan shall be prepared.
         4103.2.2 Content. The plan shall be based upon a site-specific, wildfire risk assessment that includes considerations of location, topography, aspect, flammable vegetation, climatic conditions and fire history. The plan shall also address water supply, fire department access, requirements for ignition-resistant construction and other ignition-resistance factors, fire protection systems and equipment, defensible space, and vegetation management, audit process, and other information as required by the fire code official.
            4103.2.2.1 Vegetation Management. This section shall describe all actions that will be taken to prevent a fire from being carried toward or away from the structure(s), and shall include at least the following information:
               1.   Methods and timetables for controlling, changing or modifying areas on the property to create and maintain defensible space. Elements of the plan shall include removal of slash, snags, vegetation that may grow into overhead electrical lines, other ground fuels, ladder fuels and dead trees, and the thinning of live trees, landscaping plans, etc.
               2.   A plan for maintaining the proposed hazardous fuel-reduction and mitigation measures.
               3.   A plan or process to monitor and report the implementation of the vegetation management actions.
         4103.2.3 Maintenance. The Wildfire Safety Plan shall be incorporated into the CC&R's for subdivisions to ensure long-term maintenance and adherence to these requirements.
         4103.2.4 Cost. The cost of plan preparation and review shall be the responsibility of the applicant.
         4103.2.5 Plan Retention. The plan shall be retained by the code official.
         4103.2.6 Qualifications. The plan shall be prepared by a special expert (e.g. Wildfire Mitigation Specialist) or other person demonstrating the competence and relevant wildfire mitigation experience or training. The preparer shall be acceptable and approved by the fire code official.
   4104 DEFINITIONS
      ACCESSORY STRUCTURE. A building or structure used to shelter or support any material, equipment, chattel or occupancy other than a habitable building.
      DEFENSIBLE SPACE. An area either natural or manmade, where material capable of allowing a fire to spread unchecked has been treated, cleared or modified to slow the rate and intensity of an advancing wildfire and to create an area for fire suppression operations to occur.
      FIRE-RESISTANCE-RATED CONSTRUCTION. The use of materials and systems in the design and construction of a building or structure to safeguard against the spread of fire within a building or structure and the spread of fire to or from buildings or structures to wildland fuels.
      FLAME SPREAD INDEX. A comparative measure, expressed as a dimensionless number, derived from visual measurements of the spread of flame versus time for a material tested in accordance with ASTM E 84 or UL 723. Flame spread index ratings and ranges are as follows:
         1.   Class A - (0 - 25);
         2.   Class B - (26 - 75);
         3.   Class C - (76 - 200).
      FUEL MODIFICATION. A method of modifying fuel load by reducing the amount of non-fire-resistive vegetation or altering the type of vegetation to reduce the fuel load.
      FUEL MOSAIC. A fuel modification system that provides for the creation of islands and irregular boundaries to reduce the visual and ecological impact of fuel modification.
      IGNITION-RESISTANT BUILDING MATERIAL. A type of building material that resists ignition or sustained flaming combustion sufficiently so as to reduce losses from wildland-urban interface conflagrations under worst-case weather and fuel conditions with wildfire exposure of burning embers and small flames, as prescribed in Section 4108.
      IGNITION-RESISTANT CONSTRUCTION, CLASS 1 (IR1), AND CLASS 2 (IR2). A schedule of additional requirements for construction in wildland-urban interface areas based on representative fire hazard.
      LOG WALL CONSTRUCTION. A type of construction in which exterior walls are constructed of solid wood members and where the smallest horizontal dimension of each solid wood member is at least 6 inches.
      MULTILAYERED GLAZED PANELS. Window or door assemblies that consist of two (2) or more independently glazed panels installed parallel to each other, having a sealed air gap in between, within a frame designed to fill completely the window or door opening in which the assembly is intended to be installed.
      NONCOMBUSTIBLE. As applied to building construction material, means a material that, in the form in which it is used, is either one of the following:
         1.   Material of which no part will ignite and burn when subjected to fire. Any material conforming to ASTM E 136 shall be considered noncombustible within the meaning of this section.
         2.   Material having a structural base of noncombustible material as defined in Item 1 above, with a surfacing material not over 1/8-inch-thick, which has a flame spread index of 50 or less. Flame spread index as used herein refers to a flame spread index obtained according to tests conducted as specified in ASTM E 84 or UL 723.
      "Noncombustible" does not apply to surface finish materials. Material required to be noncombustible for reduced clearances to flues, heating appliances or other sources of high temperature shall refer to material conforming to Item 1. No material shall be classified as noncombustible that is subject to an increase in combustibility or flame spread index, beyond the limits herein established, through the effects of age, moisture or other atmospheric condition.
      NONCOMBUSTIBLE ROOF COVERING. A roof covering consisting of any of the following:
         1.   Cement shingles or sheets;
         2.   Exposed concrete slab roof;
         3.   Ferrous or copper shingles or sheets;
         4.   Slate shingles;
         5.   Clay or concrete roofing tile;
         6.   Approved roof covering of noncombustible material.
      OPEN BURNING. The burning of materials wherein products of combustion are emitted directly into the ambient air without passing through a stack or chimney from an enclosed chamber. Open burning does not include road flares, smudge-pots and similar devices associated with safety or occupational uses typically considered open flames. Recreational fires or use of portable outdoor fireplaces shall be considered open burning. For the purpose of this definition, a chamber shall be regarded as enclosed when, during the time combustion occurs, only apertures, ducts, stacks, flues, or chimneys necessary to provide combustion air and permit the escape of exhaust gas are open.
      SETBACK. Distance from the nearest lot line to any portion of a structure, including appendages (e.g. decks, etc.).
      SLOPE. The variation of terrain from the horizontal; the number of feet rise or fall per 100 feet measured horizontally, expressed as a percentage.
      SPECIAL EXPERT. An individual who has demonstrated qualifications in a specific area, outside of the practice of architecture or engineering, through education, training, and experience.
      STRUCTURE. That which is built or constructed.
      SUBDIVISION. The division of a tract, lot or parcel of land into two or more lots, plats, sites or other divisions of land.
      TREE CROWN. The primary and secondary branches growing out from the main stem, together with twigs and foliage, normally considered the upper part of the tree.
      UNDEVELOPED PROPERTY. Land that is largely in a natural condition, is primarily non-irrigated and non-paved and is often connected to other similarly undeveloped land that constitutes part of the wildland or wildland-urban interface, including natural open space. The code official shall determine when property constitutes undeveloped property.
      UNENCLOSED ACCESSORY STRUCTURE. An accessory structure without a complete exterior wall system enclosing the area under roof or floor above.
      WILDFIRE. An uncontrolled fire spreading through vegetative fuels, exposing and possibly consuming structures.
      WILDFIRE SAFETY PLAN. A document prepared for a specific project or development proposed for wildland-urban interface areas. It describes ways to minimize and mitigate the fire problems created by the project or development, with the purpose of reducing the impact on the community's fire protection delivery system.
      WILDLAND. An area in which development is essentially nonexistent, except for roads, railroads, power lines and similar facilities.
      WILDLAND-URBAN INTERFACE AREA. That geographical area where structures and other human development meets or intermingles with wildland or vegetative fuels.
   4105 WILDLAND-URBAN INTERFACE (WUI) AREA DESIGNATIONS
      4105.1 Declaration. The fire code official shall declare the wildland-urban interface (WUI) and ignition-resistant (IR) construction areas within the jurisdiction. These areas and designations shall be based on best available data.
      4105.2 Mapping. Wildland-urban interface areas shall be recorded on maps available for inspection by the public. The wildland-urban interface area boundary shall correspond to natural or manmade features. These maps are generalized depictions of the WUI area boundaries. The fire code official shall have final authority in determining which lots shall be included within each area.
         4105.2.1 General IR1 Areas. Areas required to utilize Class 1 Ignition-Resistant Construction (IR1) shall generally depict foothills fire hazard areas. Further, as the city annexes land to the north and west, the IR1 areas will be automatically modified to include annexed lands that are generally north and west of Hill Road.
         4105.2.2 General IR2 Areas. Areas required to utilize Class 2 Ignition-Resistant Construction (IR2) shall generally depict valley, desert, and other occluded fire hazard areas that do not include sloped terrain. Interior lots for IR1 areas may be allowed to utilize Class 2 Ignition-Resistant Construction (IR2) as determined by the code official.
         4105.2.3 Other Areas. The fire code official shall determine additional areas at threat from wildfire. These areas may include properties adjacent to occluded undeveloped properties, in areas not historically considered wildland-urban interface.
      4105.3 Review of Wildland-Urban Interface Areas. The fire code official shall reevaluate and recommend modification to the wildland-urban interface areas in accordance with Section 4105.1 on a 5-year basis, or more frequently as deemed necessary by the fire code official.
   4106 ACCESS AND WATER SUPPLY
      4106.1 General. Access and water supply shall be in accordance with the International Fire Code and Boise City Code.
   4107 BUILDING CONSTRUCTION REGULATIONS
      4107.1 Scope. Buildings and structures hereafter constructed, modified or relocated into or within WUI areas shall meet the construction requirements in accordance with this code, the International Building Code, International Fire Code and Boise City Code.
      Exceptions:
         1.   Detached accessory structures not exceeding 200 square feet in floor area where located 50 feet or more from buildings containing habitable spaces.
         2.   Agricultural buildings located 50 feet or more from buildings containing habitable spaces.
      4107.2 Objective. The objective of Sections 4107 through 4113 is to establish minimum standards to locate, design and construct buildings and structures or portions thereof for the protection of life and property, to resist damage from wildfires, and to mitigate building and structure fires from spreading to wildland fuels. The minimum standards set forth in this chapter vary with the critical fire weather, slope and fuel type, to provide increased protection, above the requirements set forth in the International Building Code, from the various levels of hazards.
      4107.3 Fire-Resistance-Rated Construction. Where this code requires 1-hour fire-resistance-rated construction, the fire-resistance rating of building elements, components or assemblies shall be determined in accordance with the test procedures set forth in ASTM E 119 or UL 263.
      Exceptions:
         1.   The fire-resistance rating of building elements, components or assemblies based on the prescriptive designs prescribed in Section 721 of the International Building Code.
         2.   The fire-resistance rating of building elements, components or assemblies based on the calculation procedures in accordance with Section 722 of the International Building Code.
      4107.4 Setbacks to Undeveloped Natural Open Space. The minimum required setback from any portion of a structure, including appendages, to undeveloped natural open space shall not be less than 30 feet. Setback distances may be increased, depending upon topographical or other site-specific conditions, as determined by the code official.
   4108 IGNITION-RESISTANT CONSTRUCTION AND MATERIAL
      4108.1 General. Buildings and structures hereafter constructed, modified or relocated into or within wildland-urban interface areas shall meet site-specific construction requirements based on a determination by the code official. Class 1 (IR1), and Class 2 (IR2), ignition-resistant construction shall be in accordance with Sections 4109, and 4110, respectively. Materials required to be ignition-resistant materials shall comply with the requirements of Section 4108.2, the International Building Code, International Fire Code and Boise City Code.
      4108.2 Ignition-Resistant Building Material. Ignition-resistant building materials shall comply with any one of the following:
         1.   Material shall be tested on all sides with the extended ASTM E 84 (UL 723) test or ASTM E 2768, except panel products shall be permitted to test only the front and back faces. Panel products shall be tested with a ripped or cut longitudinal gap of 1/8 inch (3.2 mm). Materials that, when tested in accordance with the test procedures set forth in ASTM E 84 or UL 723 for a test period of 30 minutes, or with ASTM E 2768, comply with the following:
            1.1.   Flame spread. Material shall exhibit a flame spread index not exceeding 25 and shall not show evidence of progressive combustion following the extended 30-minute test.
            1.2.   Flame front. Material shall exhibit a flame front that does not progress more than 10-1/2 feet (3200 mm) beyond the centerline of the burner at any time during the extended 30-minute test.
            1.3.   Weathering. Ignition-resistant building materials shall maintain their performance in accordance with this section under conditions of use. Materials shall meet the performance requirements for weathering (including exposure to temperature, moisture and ultraviolet radiation) contained in the following standards, as applicable to the materials and the conditions of use:
               1.3.1. Method A "Test Method for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing" in ASTM D 2898, for fire-retardant-treated wood, wood-plastic composite and plastic lumber materials.
               1.3.2. ASTM D 7032 for wood-plastic composite materials.
               1.3.3. ASTM D 6662 for plastic lumber materials.
            1.4.   Identification. All materials shall bear identification showing the fire test results.
            Exception: Materials comprised of a combustible core and a noncombustible exterior covering, comprised of either aluminum at a minimum 0.019 inch (0.48 mm) thickness or corrosion-resistant steel at a minimum 0.0149 inch (0.38 mm) thickness shall not be required to be tested with a ripped or cut longitudinal gap.
      2.   Noncombustible material. Material that meets the definition of noncombustible in Section 4104.
      3.   Fire-retardant-treated wood. Fire-retardant-treated wood identified for exterior use and meeting the requirements of Section 2303.2 of the International Building Code.
      4.   Fire-retardant-treated wood roof coverings. Roof assemblies containing fire-retardant-treated wood shingles and shakes that comply with the requirements of Section 1505.6 of the International Building Code and classified as Class A roof assemblies as required in Section 1505.2 of the International Building Code.
   4109 CLASS 1 IGNITION-RESISTANT CONSTRUCTION (IR1)
      4109.1 General. Class 1 ignition-resistant construction shall be in accordance with Sections 4109.2 through 4109.11.
      4109.2 Roof Covering. Roofs shall have a roof assembly or roof covering, which shall comply with a Class A rating when tested in accordance with ASTM E 108 or UL 790. For roof coverings where the profile allows a space between the roof covering and roof decking, the space at the eave ends shall be fire-stopped to preclude entry of flames or embers, or have one layer of 72-pound mineral-surfaced, nonperforated cap sheet complying with ASTM D 3909 installed over the combustible decking.
      Exceptions:
         1.   Class A roof assemblies include those with coverings of brick, masonry or an exposed concrete roof deck.
         2.   Class A roof assemblies also include ferrous or copper shingles or sheets, metal sheets and shingles, clay or concrete roof tile or slate installed on noncombustible decks or ferrous, copper or metal sheets installed without a roof deck on noncombustible framing.
         3.   Class A roof assemblies include minimum 16 oz/sq. ft. copper sheets installed over combustible decks.
      4109.2.1 Roof Valleys. When provided, valley flashings shall be not less than 0.019 inch (No. 26 galvanized sheet gage) corrosion-resistant metal installed over a minimum 36-inch-wide underlayment consisting of one layer of 72-pound mineral-surfaced, nonperforated cap sheet complying with ASTM D 3909 running the full length of the valley.
      4109.3 Protection of Eaves. Eaves and soffits shall be protected on the exposed underside by ignition-resistant materials in accordance with Section 4108.2 or by materials approved for not less than 1-hour fire resistance-rated construction, 2-inch nominal dimension lumber, or 1-inch nominal fire-retardant-treated lumber or 3/4-inch nominal fire-retardant-treated plywood, identified for exterior use and meeting the requirements of Section 2303.2 of the International Building Code. Fascia's are required and shall be protected on the backside by ignition-resistant materials in accordance with Section 4108.2 or by materials approved for not less than 1-hour fire-resistance-rated construction or 2-inch nominal dimension lumber.
      4109.4 Gutters and Downspouts. Gutters and downspouts shall be constructed of noncombustible material. Gutters shall be provided with an approved means to prevent the accumulation of leaves and debris in the gutter.
      4109.5 Exterior Walls. Exterior walls of buildings or structures shall be constructed with one of the following methods:
         1.   Materials approved for not less than 1-hour fire- resistance-rated construction on the exterior side;
         2.   Approved noncombustible materials;
         3.   Heavy timber or log wall construction;
         4.   Fire-retardant-treated wood on the exterior side. The fire-retardant-treated wood shall be labeled for exterior use and meet the requirements of Section 2303.2 of the International Building Code;
         5.   Ignition-resistant materials complying with Section 4108.2 on the exterior side.
      Such material shall extend from the top of the foundation to the underside of the roof sheathing.
      4109.6 Underfloor Enclosure. Buildings or structures shall have underfloor areas enclosed to the ground with exterior walls in accordance with Section 4109.5.
      Exception: Complete enclosure shall not be required where the underside of exposed floors and exposed structural columns, beams and supporting walls are protected as required for exterior 1-hour fire-resistance-rated construction or heavy timber construction or fire-retardant-treated wood. The fire-retardant-treated wood shall be labeled for exterior use and meet the requirements of Section 2303.2 of the International Building Code.
      4109.7 Appendages and Projections. Unenclosed accessory structures attached to buildings with habitable spaces and projections, such as decks, shall be not less than 1-hour fire-resistance-rated construction or constructed of one of the following:
         1.   Approved noncombustible materials;
         2.   Fire-retardant-treated wood identified for exterior use and meeting the requirements of Section 2303.2 of the International Building Code;
         3.   Ignition-resistant building materials in accordance with Section 4108.2;
         4.   Heavy timber construction with following minimum dimensions: 6 by 6-inches for columns, 4 by 8-inches for joists, 4 by 10-inches or 6 by 8-inches for beams and 3 by 4-inches for ledgers.
         4109.7.1 Underfloor Areas. Where the attached structure is located and constructed so that the structure or any portion thereof projects over a descending slope surface greater than 10 percent, the area below the structure shall have underfloor areas enclosed to within 6 inches of the ground, with exterior wall construction in accordance with Section 4109.5.
      4109.8 Exterior Glazing. Exterior windows, window walls and glazed doors, windows within exterior doors, and skylights shall be tempered glass, multilayered glazed panels, glass block or have a fire protection rating of not less than 20 minutes.
      4109.9 Exterior Doors. Exterior doors shall be approved noncombustible construction, solid core wood not less than 1-3/4 inches thick or have a fire protection rating of not less than 20 minutes. Windows within doors and glazed doors shall be in accordance with Section 4109.8.
      Exception: Vehicle access doors.
      4109.10 Vents. Attic ventilation openings, foundation or underfloor vents, or other ventilation openings in vertical exterior walls and vents through roofs shall not exceed 144 square inches each. Such vents shall be covered with noncombustible corrosion-resistant mesh with openings not to exceed 1/8 inch or shall be designed and approved to prevent flame or ember penetration into the structure.
         Exceptions:
            1.   Clothes dryer and plumbing vents are exempt from the installation of the mesh covering.
            2.   Appliance vents that are prohibited by the manufacturer to be covered by mesh.
            3.   Where noncombustible exhaust vents with louvers, and 1/4-inch wire mesh screens are provided, which prevent the intrusion of embers into a vent opening.
            4.   Where no acceptable alternative exists for air intake vents.
         4109.10.1 Vent Locations. Attic ventilation openings shall not be located in soffits, in eave overhangs, between rafters at eaves, or in other overhang areas. Gable end and dormer vents shall be located at least 10 feet from lot lines. Underfloor ventilation openings shall be located as close to grade as practical.
         Exception: Fire-rated vents designed to prevent flame or ember penetration into the structure may be allowed as approved by the fire code official.
         4109.10.2 Vent Materials. Plumbing and appliance vents are not required to be of a noncombustible material unless required by the manufacturer of the appliance.
      4109.11 Detached Accessory Structures. Detached accessory structures, located less than 50 feet from a building containing habitable space shall have exterior walls constructed with materials approved for not less than 1-hour fire-resistance-rated construction, heavy timber, log wall construction, or constructed with approved noncombustible materials or fire-retardant-treated wood on the exterior side. The fire-retardant-treated wood shall be labeled for exterior use and meet the requirements of Section 2303.2 of the International Building Code.
         4109.11.1 Underfloor Areas. Where the detached structure is located and constructed so that the structure or any portion thereof projects over a descending slope surface greater than 10 percent, the area below the structure shall have underfloor areas enclosed to within 6 inches of the ground, with exterior wall construction in accordance with Section 4109.5 or underfloor protection in accordance with Section 4109.6.
         Exception: The enclosure shall not be required where the underside of exposed floors and exposed structural columns, beams and supporting walls are protected as required for exterior 1-hour fire-resistance-rated construction or heavy-timber construction or fire-retardant-treated wood on the exterior side. The fire-retardant-treated wood shall be labeled for exterior use and meet the requirements of Section 2303.2 of the International Building Code.
   4110 CLASS 2 IGNITION-RESISTANT CONSTRUCTION (IR2)
      4110.1 General. Class 2 ignition-resistant construction shall be in accordance with Sections 4109.
         Exceptions:
         1.   Protection of Eaves. Combustible eaves, fascia's and soffits shall be enclosed with solid materials with a minimum thickness of 3/4 inch. Exposed rafter tails shall not be permitted unless constructed of heavy timber materials.
         2.   Appendages and Projections. Deck boards with a Class A or Class B flame spread rating are allowed.
   4111 INSTALLATION, REPAIR AND REPLACEMENT OF FENCES
      4111.1 General. This section shall apply for all new installations of fences and replacement of existing fence sections. All fence and/or gate sections within eight feet (8') of any habitable structure shall be constructed of noncombustible materials only. Combustible fencing shall not be allowed within eight feet (8') of a habitable structure.
   4112 REPLACEMENT OR REPAIR OF ROOF COVERINGS
      4112.1 General. The roof covering on buildings or structures in existence prior to the adoption of this code that are replaced or have 50 percent or more replaced in a 12-month period shall be replaced with a roof covering required for new construction based on the type of ignition-resistant construction specified in accordance with Section 4108 through 4111.
   4113 REPLACEMENT OR REPAIR OF SIDING
      4113.1 General. The siding on buildings or structures in existence prior to the adoption of this code that are replaced or have 50 percent or more replaced in a 12-month period shall be replaced with siding required for new construction based on the type of ignition-resistant construction specified in accordance with Section 4108 through 4110.
   4114 GENERAL WILDFIRE PREVENTION AND MITIGATION REQUIREMENTS
      4114.1 Scope. The provisions of Sections 4114 through 4121 establish general requirements for new and existing buildings, structures and premises located within wildland-urban interface areas.
      4114.2 Objective. The objective of Sections 4114 through 4121 is to establish minimum requirements to mitigate the risk to life and property from wildland fire exposures, exposures from adjacent structures and to mitigate structure fires from spreading to wildland fuels.
   4115 DEFENSIBLE SPACE
      4115.1 General. Defensible space shall comply with 4115.2 to 4115.3 and be maintained in accordance with Section 4116.
      Exception: For existing structures, constructed prior to 2011, this provision applies only, if in the opinion of the fire code official, the situation constitutes a distinct hazard to life or property.
      4115.2 Objective. Provisions of this section are intended to modify the fuel load in areas adjacent to structures to create a defensible space.
      4115.3 Fuel Modification. Buildings or structures in designated wildland-urban interface (WUI) areas, shall comply with defensible space fuel modification distances as required by the code official. Fuel modification distance shall be at least 30 feet. Distances shall be measured on a horizontal plane from the perimeter or projection of the building or structure. Distances may be increased by the code official per requirements in the Wildfire Safety Plan, or because of other site-specific analysis based on local conditions.
      Exception: Fuel modification from any portion of the structure, including appendages, to a lot line that adjoins a neighboring residential lot or development. The fuel modification in this area shall be to the lot line if the distance is less than 30 feet.
         4115.3.1 Responsible Party. Persons owning, leasing, controlling, operating or maintaining buildings or structures requiring defensible spaces are responsible for modifying or removing non-fire-resistive vegetation on the property owned, leased or controlled by said person.
         4115.3.2 Trees. Trees are allowed within the defensible space, provided the horizontal distance between crowns of adjacent trees and crowns of trees and structures, overhead electrical facilities or unmodified fuel is not less than 10 feet.
         4115.3.3 Groundcover. Deadwood and litter shall be regularly removed from trees. Where ornamental vegetative fuels or cultivated ground cover, such as green grass, ivy, succulents or similar plants are used as ground cover, they are allowed to be within the designated defensible space, provided they do not form a means of transmitting fire from the native growth to any structure.
         4115.3.4 Fuel-Free Area. A fuel-free area of 5 feet is required around all structures. This area shall utilize and maintain only approved fire-resistant vegetation and noncombustible mulches (e.g. rock mulch).
   4116 MAINTENANCE OF DEFENSIBLE SPACE
      4116.1 General. Defensible spaces required by Section 4115 shall be maintained in accordance with Section 4116.
      Exception: For existing structures, constructed prior to 2011, this provision applies only, if in the opinion of the fire code official, the situation constitutes a distinct hazard to life or property.
      4116.2 Modified Area. Non-fire-resistive vegetation or growth shall be kept clear of buildings or structures, in accordance with Section 4115, in such a manner as to provide a clear area for fire suppression operations.
      4116.3 Responsibility. Persons owning, leasing, controlling, operating or maintaining buildings or structures are responsible for the maintenance of defensible spaces. Maintenance of the defensible space shall include modifying or removing non-fire-resistive vegetation and keeping leaves, needles and other dead vegetative material regularly removed from roofs of buildings and structures.
      4116.4 Trees. Tree crowns extending to within 10 feet of any structure shall be pruned to maintain a minimum horizontal clearance of 10 feet. Tree crowns within the defensible space shall be pruned to remove limbs located less than 6 feet above the ground surface adjacent to the trees.
         Exception: Shorter-stature trees shall be pruned to remove all limbs located above the ground to 1/3 of the tree crown height (e.g., a nine-foot tree shall be limbed up three feet from the ground).
         4116.4.1 Chimney Clearance. Portions of tree crowns that extend to within 10 feet of the outlet of a chimney shall be pruned to maintain a minimum horizontal clearance of 10 feet.
         4116.4.2 Deadwood Removed. Deadwood and litter shall be regularly removed from trees.
      4116.5 Water Supply. Defensible space shall be provided around water tank structures, water supply pumps and pump houses in accordance with Section 4115.
   4117 SPARK ARRESTERS
      4117.1 General. Chimneys serving fireplaces, barbecues, incinerators or decorative heating appliances in which solid or liquid fuel is used, shall be provided with a spark arrester. Spark arresters shall be constructed of woven or welded wire screening of 12 USA standard gage wire (0.1046 inch) having openings not exceeding 1/2 inch.
      4117.2 Net Free Area. The net free area of the spark arrester shall not be less than four times the net free area of the outlet of the chimney.
   4118 STORAGE OF FIREWOOD AND COMBUSTIBLE MATERIALS
      4118.1 General. Firewood and combustible material shall not be stored in unenclosed spaces beneath buildings or structures, or on decks or under eaves, canopies or other projections or overhangs. When required by the code official, unenclosed storage of firewood and combustible material in the defensible space shall be located a minimum of 20 feet from structures and separated from the crown of trees by a minimum horizontal distance of 15 feet.
      4118.2 Storage for Off-Site Use. Firewood and combustible materials not for consumption on the premises shall be stored so as to not pose a hazard.
   4119 VEGETATION CONTROL
      4119.1 General. Vegetation control shall comply with Sections 4119.2 through 4119.4.
      4119.2 Clearance of Brush or Vegetative Growth from Roadways. The code official is authorized to require areas within 10 feet on each side of portions of fire apparatus access roads and driveways to be cleared of non-fire-resistive vegetation growth.
      Exception: Single specimens of trees, ornamental vegetative fuels or cultivated ground cover, such as green grass, ivy, succulents or similar plants used as ground cover, provided they do not form a means of readily transmitting fire.
         4119.2.1 Erosion Control. Vegetation should be trimmed to not less than 6" in height on sloped terrain to maintain slope stability for erosion control.
      4119.3 Clearance of Brush and Vegetative Growth from Electrical Transmission and Distribution Lines. Clearance of brush and vegetative growth from electrical transmission and distribution lines shall be in accordance with Sections 4119.3.1 through 4119.3.2.1.
      Exception: Sections 4119.3.1 through 4119.3.2.1 do not authorize persons not having legal right of entry to enter on or damage the property of others without consent of the owner.
         4119.3.1 Support Clearance. Persons owning, controlling, operating or maintaining electrical transmission or distribution lines shall have the following programs in place:
            1.   A vegetation management program in accordance with the National Electrical Safety Code ("NESC").
            2.   A transmission and distribution line inspection program in accordance with the NESC.
            Exception: Lines used exclusively as telephone, telegraph, messenger call, alarm transmission or other lines classed as communication circuits by a public utility.
         4119.3.2 Electrical Distribution and Transmission Line Clearances. Clearances between vegetation and electrical lines shall be in accordance with the provisions of the NESC.
            4119.3.2.1 Electrical Power Line Emergencies. During emergencies, the utility shall perform the required work to the extent necessary to clear the hazard. An emergency can include situations such as trees falling into power lines, or trees in violation of clearance requirements in accordance with the NESC.
      4119.4 Correction of Condition. The code official is authorized to give notice to the owner of the property of which conditions regulated by Section 4119 exist to correct such conditions. If the owner fails to correct such conditions, the legislative body of the jurisdiction is authorized to cause the same to be done and make the expense of such correction a lien on the property where such condition exists.
   4120 ACCESS RESTRICTIONS
      4120.1 Restricted Entry. The code official is authorized to determine and publicly announce when wildland-urban interface areas shall be closed to entry and when such areas shall again be opened to entry. Entry on and occupation of wildland-urban interface areas, except public roadways, inhabited areas or established trails and campsites that have not been closed during such time when the wildland-urban interface area is closed to entry, is prohibited.
      Exceptions:
         1.   Residents and owners of private property within wildland-urban interface areas and their invitees and guests going to or being on their lands.
         2.   Entry, in the course of duty, by peace or police officers, and other duly authorized public officers, members of a fire department and members of the Wildland Firefighting Service.
   4121 IGNITION SOURCE CONTROL
      4121.1 General. Ignition sources shall be controlled in accordance with Sections 4121.2 through 4121.8.
      4121.2 Objective. Regulations in this section are intended to provide the minimum requirements to prevent the occurrence of wildfires.
      4121.3 Clearance from Ignition Sources. Clearance between ignition sources and grass, brush or other combustible materials shall be maintained at not less than 30 feet.
      4121.4 Smoking. Where required by the code official, signs shall be posted stating NO SMOKING. Persons shall not smoke within 15 feet of combustible materials or non-fire-resistive vegetation.
      Exception: Places of habitation or in the boundaries of established smoking areas or campsites as designated by the code official.
      4121.5 Equipment and Devices Generating Heat, Sparks or Open Flames. Equipment and devices generating heat, sparks or open flames capable of igniting nearby combustibles shall not be used in wildland-urban interface areas without approval by the fire code official.
      Exception: Use of approved equipment within inhabited premises or designated campsites that are not less than 30 feet from grass-, grain-, brush- or forest-covered areas.
      4121.6 Fireworks. All fireworks, including non-aerial common fireworks, shall not be used or possessed in an IR1 wildland-urban interface area per Section 4105.2. A reduction of any requirements for a lot in an IR1 area does not constitute a change for the purposes of this section.
      Exception: Fireworks allowed by the code official, under permit, in accordance with the International Fire Code where not prohibited by applicable local or state laws, ordinances and regulations.
         4121.6.1 Authority to Seize. The code official is authorized to seize, take, remove or cause to be removed fireworks in violation of this section.
      4121.7 Outdoor Fires. Outdoor fires in wildland-urban interface areas shall comply with this section, the International Fire Code and Boise City Code.
         4121.7.1 General. Persons shall not build, ignite or maintain any outdoor fire of any kind for any purpose, in an IR1 wildland-urban interface area, except by the authority of a written permit from the code official. Outdoor fires on residential lots or designated campsites, where such fires are in an outdoor fireplace, incinerator, or grill, shall be located not less than 30 feet from any combustible material or non-fire-resistive vegetation; and shall have openings protected with an approved spark arrestor, screen or door, unless otherwise approved by the code official.
         Exception:
            Propane-fired or natural gas-fired outdoor fireplaces, on residential lots, which are located not less than 15 feet from any combustible material or non-fire-resistive vegetation.
      4121.8 Incinerators, Outdoor Fireplaces, Permanent Barbecues and Grills. Incinerators, outdoor fireplaces, permanent barbecues and grills shall not be built, installed or maintained in wildland-urban interface areas without approval of the code official.
         4121.8.1 Maintenance. Incinerators, outdoor fireplaces, permanent barbecues and grills shall be maintained in good repair and in a safe condition at all times. Openings in such appliances shall be provided with an approved spark arrestor, screen or door.
         Exception: Where approved by the code official, unprotected openings in barbecues and grills necessary for proper functioning.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021; amd. Ord. 7-25, 2-25-2025)