CHAPTER 12 FIRE PREVENTION CODE
5-12-1: DECLARATION OF INTENT:
5-12-2: CODE ADOPTED:
5-12-3: IFC AMENDMENT, SECTION 101.1, TITLE:
5-12-4: IFC AMENDMENT, SECTION 103.3, DEPUTIES:
5-12-5: IFC AMENDMENT, ADD SECTION 104.2.1, FIRE DEPARTMENT PLAN REVIEW:
5-12-6: IFC AMENDMENT, SECTION 105.2.3, TIME LIMITATION OF APPLICATION:
5-12-7: IFC AMENDMENT, SECTION 105.3.2, EXTENSIONS:
5-12-8: IFC AMENDMENT, SECTION 105.3.3, OCCUPANCY PROHIBITED BEFORE APPROVAL:
5-12-9: IFC AMENDMENT, ADD SECTION 106.6, RE- REVIEW FEE:
5-12-10: IFC AMENDMENT, ADD SECTION 106.7, FIRE PROTECTION SYSTEM PLAN MODIFICATION FEE:
5-12-11: IFC AMENDMENT, ADD SECTION 106.8, REINSPECTION FEES:
5-12-12: IFC AMENDMENT, SECTION 109.1, BOARD OF APPEALS ESTABLISHED:
5-12-13: IFC AMENDMENT, SECTION 110.4, VIOLATION PENALTIES:
5-12-14: IFC AMENDMENT, SECTION 112.4, FAILURE TO COMPLY:
5-12-15: IFC AMENDMENT, SECTION 202, GENERAL DEFINITIONS:
5-12-16: IFC AMENDMENT, SECTION 304.1.2, VEGETATION:
5-12-17: IFC AMENDMENT, SECTION 307.2, PERMIT REQUIRED:
5-12-18: IFC AMENDMENT, SECTION 307.2.2, AIR QUALITY INDEX:
5-12-19: IFC AMENDMENT, ADD SECTION 315.3.5, STORAGE HEIGHT SIGNAGE:
5-12-20: IFC AMENDMENT, ADD SECTION 401.8.1, SILENCING FIRE ALARMS:
5-12-21: IFC AMENDMENT, SECTION 503.1.1, BUILDINGS AND FACILITIES:
5-12-22: IFC AMENDMENT, SECTION 503.2.4, TURNING RADIUS:
5-12-23: IFC AMENDMENT, SECTION 503.2.6, BRIDGES AND ELEVATED SURFACES:
5-12-24: IFC AMENDMENT, ADD SECTION 503.3.1, SIGNAGE:
5-12-25: IFC AMENDMENT, ADD SECTION 503.5.2, BARRICADE SPECIFICATIONS:
5-12-26: IFC AMENDMENT, ADD SECTION 503.7, DIVE BOAT ACCESS:
5-12-27: IFC AMENDMENT, ADD SECTION 505.1.1, CORNER LOTS:
5-12-28: IFC AMENDMENT, ADD SECTION 505.1.2, TENANT SPACE IDENTIFICATION:
5-12-29: IFC AMENDMENT, ADD SECTION 505.1.3, ADDRESSES FOR MULTIFAMILY DWELLINGS:
5-12-30: IFC AMENDMENT, SECTION 506.1, KEY BOXES WHERE REQUIRED:
5-12-31: IFC AMENDMENT, SECTION 507.2, TYPE OF WATER SUPPLY:
5-12-32: IFC AMENDMENT, SECTION 507.5.1, FIRE HYDRANT SYSTEMS WHERE REQUIRED:
5-12-33: IFC AMENDMENT, ADD SECTION 507.5.7, FIRE HYDRANT SUPPLY CONNECTIONS:
5-12-34: IFC AMENDMENT, SECTION 701.6, OWNER’S RESPONSIBILITY:
5-12-35: IFC AMENDMENT, ADD SECTION 901.4.2.1, NON- REQUIRED FIRE ALARM SYSTEMS:
5-12-36: IFC AMENDMENT, ADD SECTION 903.3.1.1.3, SPECULATIVE WAREHOUSE:
5-12-37: IFC AMENDMENT, ADD SECTION 903.3.1.3.1, NFPA 13D ALARMS:
5-12-38: IFC AMENDMENT, ADD SECTION 903.3.5.3, CONTROL VALVE LOCATION:
5-12-39: IFC AMENDMENT, ADD SECTION 903.3.5.4, DEPTH OF COVER:
5-12-40: IFC AMENDMENT, SECTION 903.4.3, FLOOR CONTROL ASSEMBLY:
5-12-41: IFC AMENDMENT, ADD SECTION 904.7.2, USE OF FOAM-WATER SUPPRESSION SYSTEMS:
5-12-42: IFC AMENDMENT, ADD SECTION 906.5.1, MULTI- STORY INSTALLATION NEAR STAIRWELLS:
5-12-43: IFC AMENDMENT, ADD SECTION 907.6.6.3, SINGLE COMMUNICATION PATH MONITORING SYSTEMS:
5-12-44: IFC AMENDMENT, ADD SECTION 907.6.7, FACP LOCATION AND IDENTIFICATION:
5-12-45: IFC AMENDMENT, ADD SECTION 912.2.3, DISTANCE TO ACCESS AND WATER SUPPLY:
5-12-46: IFC AMENDMENT, SECTION 914.3.1.2, WATER SUPPLY TO REQUIRED FIRE PUMPS:
5-12-47: IFC AMENDMENT, ADD SECTION 914.8.3.3, USE OF FOAM SYSTEMS IN AIRCRAFT HANGARS:
5-12-48: IFC AMENDMENT, SECTION 1101.1, SCOPE:
5-12-49: IFC AMENDMENT, SECTION 2007.6, FOAM PROTECTION:
5-12-50: IFC AMENDMENT, SECTION 3304.5, FIRE WATCH:
5-12-51: IFC AMENDMENT, ADD SECTION 3304.9, FIRE SAFETY REQUIREMENTS FOR BUILDINGS OF TYPES IV-A, IV-B, AND IV-C CONSTRUCTION:
5-12-52: IFC AMENDMENT, ADD CHAPTER 40, CHILDCARE FACILITIES:
5-12-53: IFC AMENDMENT, ADD CHAPTER 41, WILDLAND- URBAN INTERFACE (WUI) CODE:
5-12-54: IFC AMENDMENT, SECTION 5601.1.3, FIREWORKS:
5-12-55: IFC AMENDMENT, SECTION 5609, FIREWORKS SALES AND USE:
5-12-56: IFC AMENDMENT, CHAPTER 80, REFERENCED STANDARDS:
5-12-57: IFC AMENDMENT, ADOPT APPENDIX B, FIRE-FLOW REQUIREMENTS FOR BUILDINGS:
5-12-58: IFC AMENDMENT, APPENDIX B, SECTION B104.2, AREA SEPARATION, ADD EXCEPTION:
5-12-59: IFC AMENDMENT, ADOPT APPENDIX C, FIRE HYDRANT LOCATIONS AND DISTRIBUTION:
5-12-60: IFC AMENDMENT, ADOPT APPENDIX D, FIRE APPARATUS ACCESS ROADS:
5-12-61: IFC AMENDMENT, AMEND SECTION D103.2, GRADE:
5-12-62: IFC AMENDMENT, AMEND SECTION D103.5, FIRE APPARATUS ACCESS ROAD GATES:
5-12-63: IFC AMENDMENT, D107.1, ONE- OR TWO-FAMILY DWELLING RESIDENTIAL DEVELOPMENTS:
5-12-64: IFC AMENDMENT, ADOPT APPENDIX F, HAZARD RANKING:
5-12-65: IFC AMENDMENT, ADOPT APPENDIX L, REQUIREMENTS FOR FIRE FIGHTER AIR REPLENISHMENT SYSTEMS:
5-12-66: IFC AMENDMENT, APPENDIX L, L101.1, SCOPE:
5-12-67: IFC AMENDMENT, CHAPTER 42, REQUIREMENTS FOR STORAGE, MANUFACTURING, OR USAGE OF LITHIUM METAL AND LITHIUM-ION BATTERIES:
CHAPTER 13 PUBLIC SAFETY EMERGENCY RESPONSE COST RECOVERY
CHAPTER 14 LOST, ABANDONED, UNCLAIMED PERSONAL PROPERTY
CHAPTER 15 DISCRIMINATION PROHIBITED
CHAPTER 16 RESIDENTIAL RENTAL APPLICATION FEES - REQUIREMENTS AND PROHIBITIONS
CHAPTER 17 TENANT PROTECTIONS
TITLE 6 MOTOR VEHICLES AND TRAFFIC
TITLE 7 PUBLIC WAYS AND PROPERTY
TITLE 8 AIRPORT
TITLE 9 BUILDING CODES AND REGULATIONS
TITLE 10 PUBLIC UTILITIES
TITLE 11 DEVELOPMENT CODE
PARALLEL REFERENCES
Loading...
5-12-45: IFC AMENDMENT, ADD SECTION 912.2.3, DISTANCE TO ACCESS AND WATER SUPPLY:
   912.2.3 Distance to Access and Water Supply. Fire department connections (FDC's) and associated outside alarm indicator shall be installed within 100 feet of an approved fire apparatus access lane and within 300 feet of a fire hydrant.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021)
5-12-46: IFC AMENDMENT, SECTION 914.3.1.2, WATER SUPPLY TO REQUIRED FIRE PUMPS:
   914.3.1.2 Water supply to required fire pumps. In all buildings that are more than 420 feet (128 m) in building height, and buildings of Type IV-A and IV-B construction that are more than 120 feet (36.6 m) in building height, required fire pumps shall be supplied by connections to not fewer than two water mains located in different streets. Separate supply piping shall be provided between each connection to the water main and the pumps. Each connection and the supply piping between the connection and the pumps shall be sized to supply the flow and pressure required for the pumps to operate.
      Exception: Two connections to the same main shall be permitted provided that the main is valved such that an interruption can be isolated so that the water supply will continue without interruption through not fewer than one of the connections.
(Ord. 50-21, 11-30-2021, eff. 1-1-2022)
5-12-47: IFC AMENDMENT, ADD SECTION 914.8.3.3, USE OF FOAM SYSTEMS IN AIRCRAFT HANGARS:
   914.8.3.3 Use of Foam Systems in Aircraft Hangars
   Only UL listed flourine-free foam shall be used for the installation or modification of a foam-water suppression system. Proper disposal shall be provided for the flourine foam being replaced as approved by the fire code official.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021; amd. Ord. 7-25, 2-25-2025)
5-12-48: IFC AMENDMENT, SECTION 1101.1, SCOPE:
   1101.1 Scope. The provisions of this chapter shall apply to existing buildings constructed prior to the adoption of this code, if in the opinion of the fire code official they constitute a distinct hazard to life or property.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021)
5-12-49: IFC AMENDMENT, SECTION 2007.6, FOAM PROTECTION:
   Section 2007.6 Foam Protection. Add a paragraph to the end of 2007.6 to read as follows: Prior to the approval of any permit for the installation or modification of a foam-water suppression system, approval in writing shall be received from the fire code official. Approval shall only be permitted when in the opinion of the fire code official no reasonable alternative to these systems exist. Where permitted, mitigation measures shall be provided as approved by the fire code official.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021)
5-12-50: IFC AMENDMENT, SECTION 3304.5, FIRE WATCH:
3304.5 Fire Watch. Add a paragraph to the end of 3304.5 to read as follows:
   Where approved by the fire code official, a fire watch may be used to permit the temporary occupancy of a building before it is completed or during demolition.
(Ord. 48-20, 12-8-2020, eff. 1-1-2021)
5-12-51: IFC AMENDMENT, ADD SECTION 3304.9, FIRE SAFETY REQUIREMENTS FOR BUILDINGS OF TYPES IV-A, IV-B, AND IV-C CONSTRUCTION:
   3304.9 Fire safety requirements for buildings of Types IV-A, IV-B and IV-C construction. Buildings of Types IV-A, IV-B and IV-C construction designed to be greater than six stories above grade plane shall comply with the following requirements during construction unless otherwise approved by the fire code official.
      1.   Standpipes shall be provided in accordance with Section 3314.
      2.   A water supply for fire department operations, as approved by the fire code official and the fire chief.
      3.   Where building construction exceeds six stories above grade plane and noncombustible protection is required by Section 602.4 of the International Building Code, at least one layer of noncombustible protection shall be installed on all building elements on floor levels, including mezzanines, more than four levels below active mass timber construction before additional floor levels can be erected.
         Exception: Shafts and vertical exit enclosures shall not be considered part of the active mass timber construction.
      4.   Where building construction exceeds six stories above grade plane, required exterior wall coverings shall be installed on all floor levels, including mezzanines, more than four levels below active mass timber construction before additional floor levels can be erected.
         Exception: Shafts and vertical exit enclosure shall not be considered part of the active mass timber construction.
(Ord. 50-21, 11-30-2021, eff. 1-1-2022)