Skip to code content (skip section selection)
Compare to:
Boise Overview
Boise, ID Code of Ordinances
CITY CODE of BOISE CITY, IDAHO
ORDINANCES PENDING REVIEW FOR CODIFICATION
ADOPTING ORDINANCE
TITLE 1 ADMINISTRATION
TITLE 2 BOARDS, COMMISSIONS, COMMITTEES
TITLE 3 LICENSES AND PERMITS
TITLE 4 HEALTH AND SANITATION
TITLE 5 PUBLIC SAFETY
TITLE 6 MOTOR VEHICLES AND TRAFFIC
TITLE 7 PUBLIC WAYS AND PROPERTY
TITLE 8 AIRPORT
TITLE 9 BUILDING CODES AND REGULATIONS
CHAPTER 1 BUILDING CODE
ARTICLE A. BUILDING CODE
9-1A-1: PURPOSE:
9-1A-2: CODE ADOPTED:
9-1A-3: IBC BUILDING CODE AMENDMENT, SECTION 101.1, TITLE:
9-1A-4: IBC BUILDING CODE AMENDMENT, SECTION 101.4.3, APPLICABLE PLUMBING CODE:
9-1A-5: IBC BUILDING CODE AMENDMENT, SECTION 101.4.4, PROPERTY MAINTENANCE CODE DELETED:
9-1A-6: IBC BUILDING CODE AMENDMENT, ADD SECTION 101.4.8, ABATEMENT OF DANGEROUS BUILDINGS CODE:
9-1A-7: IBC BUILDING CODE AMENDMENT, ADD SECTION 101.4.9, APPLICABLE ELECTRICAL CODE:
9-1A-8: IBC BUILDING CODE AMENDMENT, SECTION 102.6, EXISTING STRUCTURES:
9-1A-9: IBC BUILDING CODE AMENDMENT, SECTION 102.6.2, BUILDINGS PREVIOUSLY OCCUPIED:
9-1A-10: IBC BUILDING CODE AMENDMENT, SECTION 103, DIVISION OF BUILDING SAFETY:
9-1A-11: IBC BUILDING CODE AMENDMENT, SECTION 104.10.1, FLOOD HAZARD AREAS:
9-1A-12: IBC BUILDING CODE AMENDMENT, SECTION 105.1.1, ANNUAL PERMIT:
9-1A-13: IBC BUILDING CODE AMENDMENT, ADD SECTION 105.1.3, FACILITY PERMITTING:
9-1A-14: IBC BUILDING CODE AMENDMENT, SECTION 105.2, WORK EXEMPT FROM PERMIT:
9-1A-15: IBC BUILDING CODE AMENDMENT, SECTION 105.2, DELETING SUBSECTIONS ON ELECTRICAL, GAS, MECHANICAL, AND PLUMBING:
9-1A-16: IBC BUILDING CODE AMENDMENT, SECTION 105.2.1, EMERGENCY REPAIRS:
9-1A-17: IBC BUILDING CODE AMENDMENT, ADD SECTION 105.2.1.1, REPAIRS:
9-1A-18: IBC BUILDING CODE AMENDMENT, SECTION 105.3, APPLICATION FOR PERMIT:
9-1A-19: IBC BUILDING CODE AMENDMENT, SECTION 105.3.2, TIME LIMITATION OF APPLICATION:
9-1A-20: IBC BUILDING CODE AMENDMENT, SECTION 105.5, EXPIRATION:
9-1A-21: IBC BUILDING CODE AMENDMENT, ADD SECTION 105.8, PERMIT TRANSFER:
9-1A-22: IBC BUILDING CODE AMENDMENT, SECTION 107.1 AND THE EXCEPTIONS, SUBMITTAL DOCUMENTS:
9-1A-23: IBC BUILDING CODE AMENDMENT, ADD SECTION 107.2.1.1, FOOD-PRODUCTS PREPARATION OR SALES:
9-1A-24: IBC BUILDING CODE AMENDMENT, SECTION 107.2.6.1, DESIGN FLOOD ELEVATIONS:
9-1A-25: IBC BUILDING CODE AMENDMENT, ADD SECTION 107.3.3.1, EARLY START APPROVALS:
9-1A-26: IBC BUILDING CODE AMENDMENT, SECTION 108, TEMPORARY STRUCTURES AND TEMPORARY USES IN STRUCTURES INCLUDING SECTIONS 108.1 THROUGH 108.6:
9-1A-27: IBC BUILDING CODE AMENDMENT, SECTION 109.2, SCHEDULE OF PERMIT FEES:
9-1A-28: IBC BUILDING CODE AMENDMENT, SECTION 109.4, WORK COMMENCING BEFORE PERMIT ISSUANCE:
9-1A-29: IBC BUILDING CODE AMENDMENT, ADD SECTION 109.5.1, BONDS:
9-1A-30: IBC BUILDING CODE AMENDMENT, SECTION 109.6, FEE REFUNDS:
9-1A-31: IBC BUILDING CODE AMENDMENT, SECTION 110.3.3, LOWEST FLOOR ELEVATION:
9-1A-32: IBC BUILDING CODE AMENDMENT, SECTION 110.6, APPROVAL REQUIRED:
9-1A-33: IBC BUILDING CODE AMENDMENT, SECTION 111.1, CHANGE OF OCCUPANCY, EXCEPTION DELETED:
9-1A-34: IBC BUILDING CODE AMENDMENT, ADD SECTION 111.1.1, COMMERCIAL OCCUPANCY EVALUATION REQUEST:
9-1A-35: IBC BUILDING CODE AMENDMENT, ADD SECTION 111.2.1, CERTIFICATE OF COMPLETION:
9-1A-36: IBC BUILDING CODE AMENDMENT, SECTION 111.3, TEMPORARY OCCUPANCY:
9-1A-37: IBC BUILDING CODE AMENDMENT, SECTION 112.1, CONNECTION OF SERVICE UTILITIES:
9-1A-38: IBC BUILDING CODE AMENDMENT, ADD SECTION 112.4, AUTHORITY TO DISCONNECT UTILITIES FOR OCCUPANCY VIOLATIONS:
9-1A-39: IBC BUILDING CODE AMENDMENT, SECTION 113.1, BUILDING CODE BOARD OF APPEALS, ADD SECTION 113.4, APPEALS TO THE BUILDING CODE BOARD OF APPEALS AND ADD SECTION 113.5, APPEAL PROCEDURE:
9-1A-40: IBC BUILDING CODE AMENDMENT, SECTION 114.4, CRIMINAL PENALTIES AND NONCOMPLIANCE:
9-1A-41: IBC BUILDING CODE AMENDMENT, SECTION 116, UNSAFE STRUCTURES AND EQUIPMENT, SECTION 116.1, CONDITIONS:
9-1A-42: IBC BUILDING CODE AMENDMENT, SECTIONS 116.2 THROUGH 116.5, DELETE SECTIONS ON UNSAFE STRUCTURES AND EQUIPMENT:
9-1A-43: IBC BUILDING CODE AMENDMENT, ADD SECTION 117, UPGRADE AGREEMENTS:
9-1A-44: IBC BUILDING CODE AMENDMENT, SECTION 202, DEFINITION OF TOWNHOUSE:
9-1A-45: IBC BUILDING CODE AMENDMENT, SECTION 305.2.3, TWELVE OR FEWER CHILDREN IN A DWELLING UNIT:
9-1A-46: IBC BUILDING CODE AMENDMENT, SECTION 308.2.4, FIVE OR FEWER PERSONS RECEIVING CUSTODIAL CARE:
9-1A-47: IBC BUILDING CODE AMENDMENT, SECTION 308.3.2, FIVE OR FEWER PERSONS RECEIVING MEDICAL CARE:
9-1A-48: IBC BUILDING CODE AMENDMENT, SECTION 308.5.4, PERSONS RECEIVING CARE IN A DWELLING UNIT:
9-1A-49: IBC BUILDING CODE AMENDMENT, SECTION 310.4, RESIDENTIAL GROUP R-3:
9-1A-50: IBC BUILDING CODE AMENDMENT, SECTION 310.4.1, CARE FACILITIES WITHIN A DWELLING:
9-1A-51: IBC BUILDING CODE AMENDMENT, AND SECTION 602.1.2, ALTERNATIVE PROVISIONS:
9-1A-52: IBC BUILDING CODE AMENDMENT, SECTION 1503.1, GENERAL ROOF COVERING:
9-1A-53: IBC BUILDING CODE AMENDMENT, SECTION 1605.2, LOAD COMBINATIONS USING STRENGTH DESIGN OR LOAD AND RESISTANCE FACTOR DESIGN, ADD EXCEPTION 3:
9-1A-54: IBC BUILDING CODE AMENDMENT, SECTION 1605.3.1, BASIC LOAD COMBINATIONS, ADD EXCEPTION 6:
9-1A-55: IBC BUILDING CODE AMENDMENT, SECTION 1608.1, SNOW LOADS:
9-1A-56: IBC BUILDING CODE AMENDMENT, SECTION 1608.2, GROUND SNOW LOADS:
9-1A-57: IBC BUILDING CODE AMENDMENT, SECTION 1612.3, ESTABLISHMENT OF FLOOD HAZARD AREAS:
9-1A-58: IBC BUILDING CODE AMENDMENT, SECTION 1804.6, COMPACTED FILL MATERIAL:
9-1A-59: IBC BUILDING CODE AMENDMENT, SECTION 1805.1.2.1, FLOOD HAZARD AREAS:
9-1A-60: IBC BUILDING CODE AMENDMENT, SECTION 1809.5, FROST PROTECTION:
9-1A-61: IBC BUILDING CODE AMENDMENT, TABLE 2902.1, FOOTNOTE E:
9-1A-62: IBC BUILDING CODE AMENDMENT, TABLE 2902.1, FOOTNOTE F:
9-1A-63: IBC BUILDING CODE AMENDMENT, SECTION 3103.1, TEMPORARY STRUCTURES, GENERAL:
9-1A-64: IBC BUILDING CODE AMENDMENT, SECTIONS 3103.1.1 THROUGH 3103.4, DELETE SECTIONS ON TEMPORARY STRUCTURES:
9-1A-65: IBC BUILDING CODE AMENDMENT, SECTION 3113.1, RELOCATABLE BUILDINGS, GENERAL:
9-1A-66: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H101.2, SIGNS EXEMPT FROM PERMITS:
9-1A-67: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H102.1, DEFINITIONS:
9-1A-68: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H103.1, LOCATION RESTRICTIONS:
9-1A-69: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H104, IDENTIFICATION IS DELETED IN ITS ENTIRETY:
9-1A-70: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H105.1, GENERAL REQUIREMENTS, ADD EXCEPTION:
9-1A-71: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H105.2, PERMITS, DRAWINGS AND SPECIFICATIONS:
9-1A-72: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, ADD SECTION H105.2.1, ENGINEERING:
9-1A-73: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H106.1, ILLUMINATION, AND ADD EXCEPTION:
9-1A-74: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H106.2, ELECTRICAL SERVICE, AND ADD EXCEPTION:
9-1A-75: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H107.1.2, ELECTRIC SIGN FACES IS DELETED:
9-1A-76: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H107.1.3, AREA LIMITATION IS DELETED:
9-1A-77: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H109.1, HEIGHT RESTRICTIONS:
9-1A-78: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H109.3, WOOD ANCHORS AND SUPPORTS:
9-1A-79: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H112.4, HEIGHT LIMITATION IS DELETED:
9-1A-80: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H113.4, HEIGHT LIMITATION IS DELETED:
9-1A-81: IBC BUILDING CODE AMENDMENT, APPENDIX H SIGNS, SECTION H114, PORTABLE SIGNS IS DELETED IN ITS ENTIRETY INCLUDING TABLE 4-A AND TABLE 4-B:
9-1A-82: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, SECTION J101.1, SCOPE:
9-1A-83: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, SECTION J101.2, FLOOD HAZARD AREAS:
9-1A-84: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J101.3, HAZARDS:
9-1A-85: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, SECTION J103.2, EXEMPTIONS:
9-1A-86: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J103.3, FEES:
9-1A-87: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J103.3.1, GRADING PLAN REVIEW FEES:
9-1A-88: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J103.3.2, GRADING PERMIT FEES:
9-1A-89: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J103.4, BONDS:
9-1A-90: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, SECTION J105.1, GENERAL:
9-1A-91: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.1.1, REGISTERED DESIGN PROFESSIONAL:
9-1A-92: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.1.2, PERMITTEE:
9-1A-93: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.1.3, BUILDING OFFICIAL:
9-1A-94: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.1.4, NOTIFICATION OF NONCOMPLIANCE:
9-1A-95: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.1.5, TRANSFER OF RESPONSIBILITY:
9-1A-96: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, SECTION J105.2, SPECIAL INSPECTIONS:
9-1A-97: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.3, FINAL REPORTS:
9-1A-98: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.3.1, NOTIFICATION OF COMPLETION:
9-1A-99: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, SECTION J107.5, COMPACTION:
9-1A-100: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, SECTION J109.1, GENERAL:
9-1A-101: FIRE SPRINKLER AND ALTERNATIVE EXTINGUISHING SYSTEM PERMITS, PLAN REVIEW, INSPECTIONS, AND FEES:
9-1A-102: FIRE ALARM SYSTEM PERMITS, PLAN REVIEW, INSPECTIONS, AND FEES:
ARTICLE B. ONE- AND TWO-FAMILY DWELLING BUILDING CODE
CHAPTER 2 DEVELOPMENT IMPACT FEE
CHAPTER 3 SPECIAL DESIGN STANDARDS FOR TYPE V CONSTRUCTION
CHAPTER 4 PLUMBING CODE
CHAPTER 5 ELECTRICAL CODE
CHAPTER 6 UNIFORM HOUSING CODE
CHAPTER 7 MECHANICAL, FUEL GAS AND RESIDENTIAL CODES1
CHAPTER 7A MECHANICAL CODE
CHAPTER 7B FUEL GAS CODE
CHAPTER 8 SOLID FUEL HEATING APPLIANCES
CHAPTER 9 ENERGY CONSERVATION CODE
CHAPTER 10 EXISTING BUILDING CODE
CHAPTER 11 DANGEROUS BUILDINGS CODE
CHAPTER 12 MOVING, DECONSTRUCTION, OR DEMOLITION OF BUILDINGS
CHAPTER 13 GREEN CONSTRUCTION CODE
CHAPTER 14 CONSTRUCTION SITE EROSION CONTROL
TITLE 10 PUBLIC UTILITIES
TITLE 11 DEVELOPMENT CODE
PARALLEL REFERENCES
Loading...
9-1A-94: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.1.4, NOTIFICATION OF NONCOMPLIANCE:
   J105.1.4 Notification of noncompliance. If, in the course of fulfilling their respective duties under this chapter, the registered design professional finds that the work is not being done in conformance with this chapter or the approved grading plans, the discrepancies shall be reported immediately in writing to the permittee and to the building official.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
9-1A-95: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.1.5, TRANSFER OF RESPONSIBILITY:
   J105.1.5 Transfer of responsibility. If the registered design professional of record is changed during grading, the work shall be stopped until the replacement has agreed in writing to accept responsibility within the area of technical competence for approval upon completion of the work. It shall be the duty of the permittee to notify the building official in writing of such change prior to the recommencement of such grading.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
9-1A-96: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, SECTION J105.2, SPECIAL INSPECTIONS:
   J105.2 Special inspections. The special inspection requirements of Section 1705.6 shall apply to work performed under a grading permit where required by the building official.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
9-1A-97: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.3, FINAL REPORTS:
   J105.3 Final Reports. Upon completion of the rough grading work and at the final completion of the work, the following reports and drawings and supplements thereto are required for engineered grading or when professional inspection is performed for regular grading, as applicable.
      1.   An as-built grading plan prepared by the registered design professional retained to provide such services showing original ground surface elevations, as-graded ground surface elevations, lot drainage patterns, and the locations and elevations of surface drainage facilities and of the outlets of subsurface drains. As-constructed locations, elevations, and details of subsurface drains shall be shown as reported by the registered design professional. Registered design professionals shall state that to the best of their knowledge the work within their area of responsibility was done in accordance with the final approved grading plan.
      2.   A report prepared by the registered design professional retained to provide such services, including locations and elevations of field density tests, summaries of field and laboratory tests, other substantiating data, and comments on any changes made during final grading and their effect on the recommendations made in the approved soils engineering investigation report. Registered design professionals shall submit a statement that, to the best of their knowledge, the work within their area of responsibilities is in accordance with the approved soils engineering report and applicable provisions of this appendix Chapter.
      3.   A report prepared by the registered design professional retained to provide such services, including a final description of the geology of the site and any new information disclosed during the grading and the effect of same on recommendations incorporated in the approved grading plan. Registered design professionals shall submit a statement that, to the best of their knowledge, the work within their area of responsibility is in accordance with the approved engineering geology report and applicable provisions of this appendix Chapter.
      4.   The grading contractor shall submit in a form prescribed by the building official a statement of conformance with the as-built plan and the specifications.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
9-1A-98: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, ADD SECTION J105.3.1, NOTIFICATION OF COMPLETION:
   J105.3.1 Notification of completion. The permittee shall notify the building official or designee when the grading operation is ready for final inspection. Final approval shall not be given until all work, including installation of all drainage facilities and their protective devices, and all erosion control measures have been completed in accordance with the final approved grading plan, and the required reports have been submitted.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
9-1A-99: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, SECTION J107.5, COMPACTION:
   J107.5 Compaction. All fill material shall be compacted to ninety-five (95) percent of maximum density as determined by ASTM D 1557, Modified Proctor, in lifts not exceeding twelve (12) inches in depth.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
9-1A-100: IBC BUILDING CODE AMENDMENT, APPENDIX J GRADING, SECTION J109.1, GENERAL:
   J109.1 General. Unless otherwise recommended by a registered design professional, drainage facilities shall be provided in accordance with the requirements of this section. Terracing in accordance with the requirements of this section shall be provided when recommended by the registered design professional.
      Exception: Drainage facilities and terracing need not be provided where the ground slope is not steeper than 3 horizontal to 1 vertical (33 percent).
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
9-1A-101: FIRE SPRINKLER AND ALTERNATIVE EXTINGUISHING SYSTEM PERMITS, PLAN REVIEW, INSPECTIONS, AND FEES:
   A.   Approval Required: Fire sprinkler and alternative extinguishing systems plans and associated submittals, as required by the International Fire Code and sprinkler system design standard(s), shall be permitted and approved by Planning and Development Services and the Fire Department, with fees assessed and paid for, before any related work begins.
   B.   Fees Assessed: The plan review and inspection fee shall be assessed in accordance with the provisions of the Boise City Building Code Fee Schedule as adopted by the City Council, which will be kept on file at the Planning and Development Services permit counter, Boise City Clerk's office, or on the Planning and Development Services website. All permit fees shall be reviewed by the Building Code Board prior to adoption by City Council.
   C.   Work Requiring Permit: Permits shall be issued for the following work:
      1.   New fire sprinkler and alternative extinguishing systems;
      2.   Additions, modifications, and changes to existing fire sprinkler and alternative extinguishing systems, underground lines, and/or associated equipment.
      3.   All fees shall be paid in full when the permit is issued.
   D.   Other Inspection, Plan Review, and Administrative Fees: The permit fee shall cover the cost of three (3) plan reviews and two (2) field inspections for each inspection category. An additional hourly rate fee in an amount established by the Boise City Building Code Fee Schedule as adopted by the City Council may be assessed, beginning after the third review, on re-submittals of denied plans and/or calculations. An additional fee or hourly rate fee in an amount established by the Boise City Building Code Fee Schedule as adopted by the City Council may be assessed for reinspections, after hours inspections, or other additional field inspections performed.
   E.   Plan Modifications: Plan modification revisions submitted for approval after a permit and approved plans have been issued, shall be assessed the additional plan review hourly rate fee, plus the fee based on the number of sprinklers or nozzles affected by the modification.
   F.   Application Submittal Documents: Project plans and other data as required by Boise City submittal checklists shall be submitted with a completed fire sprinkler permit application, available from Boise City's Planning and Development Services Department. (Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. 2019 Code; Ord. 39-20, 12-1-2020, eff. 1-1-2021)
9-1A-102: FIRE ALARM SYSTEM PERMITS, PLAN REVIEW, INSPECTIONS, AND FEES:
   A.   Approval Required: Fire alarm system plans and associated submittals, as required by the International Fire Code and alarm system design standard(s), shall be permitted and approved by Planning and Development Services and the Fire Department, with fees assessed and paid for, before any related work begins.
   B.   Fees Assessed: The plan review and inspection fee shall be assessed in accordance with the provisions of the Boise City Building Code Fee Schedule as adopted by the City Council, which will be kept on file at the Planning and Development Services permit counter, Boise City Clerk's office, or on the Planning and Development Services website. All permit fees shall be reviewed by the Building Code Board prior to adoption by City Council.
   C.   Work Requiring Permit: Permits shall be issued for the following work:
      1.   New fire alarm systems in buildings;
      2.   Additions, modifications, and changes to existing fire alarm systems, fire suppression connections, related supplies, and/or equipment.
      3.   All fees shall be paid in full when the permit is issued.
   D.   Other Inspection, Plan Review, And Administrative Fees: The permit fee shall cover the cost of three (3) plan reviews and two (2) field inspections for each inspection category. An additional hourly rate fee in an amount established by the Boise City Building Code Fee Schedule as adopted by the City Council may be assessed beginning after the third review, on re-submittals of denied plans and/or calculations. An additional fee or hourly rate fee in an amount established by the Boise City Building Code Fee Schedule as adopted by the City Council may be assessed for reinspections, after hours inspections, or other additional field inspections performed.
   E.   Plan Modifications: Plan modification revisions submitted for approval after a permit and approved plans have been issued, shall be assessed the additional plan review hourly rate fee, plus the fee based on the number of fire alarm initiating devices affected by the modification.
   F.   Application Submittal Documents: Project plans and other data as required by Boise City submittal checklists shall be submitted with a completed fire alarm permit application, available from Boise City's Planning and Development Services Department. (Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. 2019 Code; Ord. 39-20, 12-1-2020, eff. 1-1-2021)
Loading...