H106.2 Electrical service. Signs that require electrical service shall comply with NFPA 70, National Electric Code, and the International Energy Conservation Code.
Exception: Replaced signs on existing branch circuits do not need to comply with the controls of the Energy Conservation Code of Boise City when approved by the Electrical Inspection Supervisor or designee.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
H109.1 Height restrictions. The structural frame of ground signs shall not be erected of combustible materials to a height of more than forty (40) feet above the ground. Ground signs constructed entirely of noncombustible material shall not be erected to a height of greater than one hundred (100) feet above the ground. Greater heights are permitted where approved and located so as not to create a hazard or danger to the public.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
H109.3 Wood anchors and supports. Where wood anchors or supports are embedded in the soil, the wood shall be pressure treated with an approved preservative and shall have approved corrosion resistant steel or galvanized mechanical connectors.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
H114 Portable Signs. Deleted in its entirety, including table 4-A and table 4-B.
(Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)