Consistent with the redevelopment plan, the West Bank-Casey's PUD shall incorporate a variety of light fixtures ranging from parking lot lights and roadway fixtures to pedestrian pathway lights. Lighting shall be IDA dark sky compliant unless otherwise approved by the city of West Des Moines. Included within section 6 of the Grand Avenue redevelopment plan are design specifications and requirements along with sketches and images of the intended lighting series. All lighting within the PUD area shall abide by these standards and be consistent in character to that illustrated in the Grand Avenue redevelopment plan and the Val-Gate district's iconic design intent.
As a part of the review of each site plan, a photometric plan must be submitted. During the review, the applicant must demonstrate how lighting will not adversely affect adjoining properties or patrons utilizing the public street system. Special care must be given to ensure excess light does not spill onto properties adjacent to, but not part of, the Val-Gate district.
The following general guidelines shall be in addition to the specific regulations stated within the Grand Avenue redevelopment plan regulations:
A. Street Lights: The developer of the West Bank-Casey's PUD shall install streetlights adjacent to current Grand Avenue in conjunction with development of each parcel. In addition, the developer of the West Bank-Casey's PUD shall enter into an agreement with the city stating that the developer will install steel pole streetlights along Grand Avenue in accordance with a plan provided by Mid-American Energy or its successors at such time that Grand Avenue is widened. In addition, the developer shall enter into an agreement with the city stating that the developer will install steel pole streetlights along 1st Street at such time that the overhead power is placed underground. The developer of each parcel A and B shall be responsible for the installation of streetlights along the adjacent north and west streets at such time that the streets are constructed. Each developer shall execute an agreement and waiver for the future installation of these streetlights at the time of site plan development permit approval.
B. Parking Luminaries: Fixtures shall be of a design to direct light downward and shall not have bulbs which are exposed and extend below the frame of the light fixture. Said fixtures shall not exceed twenty five feet (25') in height as measured from the ground to the top of the light structure. Fixtures used shall be consistent throughout the West Bank-Casey's PUD.
C. Building Lighting: No wall packs, or floodlighting without shields to direct the light to its intended target are allowed. In addition to cut off fixtures, particular attention shall be given to eliminate hot spots and light glare.
D. Fuel Canopy Lighting: All light fixtures attached to a fuel pump island canopy must be recessed into the canopy with flush mounted lenses. Canopy lighting shall be designed to illuminate downward and eliminate glare and spillover lighting. Architectural accent lighting in keeping with the design intent of the Val-Gate district redevelopment plan may be allowed if approved as part of the architectural design.
E. Pedestrian Pathways: Bollard or pole lighting shall be implemented along pedestrian pathways. Pole lights shall not exceed fourteen feet (14') as measured from the ground to the top of the light fixture. (Ord. 1945, 3-5-2012)