Pursuant to published notice and public hearing, as required by law, the International Building Code, 2018 Edition, published by the International Code Council, is hereby adopted in full, to include Appendix K, except for such portions as may hereinafter be deleted, modified, or amended. The following amendments, modifications, additions, and deletions to the International Building Code, 2018 Edition, are hereby made:
1. Insert Section 101.1 to read City of Waukee.
2. Delete Sections 105.2(2), 105.2(5), 105.2(6).
3. Amend Section R105.6 to include the addition of R105.6.1 Revocation of Permit. Insert Section R105.6.1 to read:
4. Revocation of Permit. It is the permit holder’s responsibility to schedule the required inspections and obtain final approvals. Failure to schedule the required inspections and receive approval of work authorized by the permit before covering said work or at completion shall result in revocation of the permit and void any associated approvals granted by the City. This failure shall also equate to working without a permit in violation of City ordinance and no future permits shall be issued to any person or company who has outstanding violations of this code or any other laws or ordinances of the City. Failure to contact the City for any inspection or follow-up prior to expiration of a permit shall be deemed a violation of this Code section. Failure to contact the City for any inspection or follow-up prior to expiration of a Temporary Certificate of Occupancy shall also be deemed a violation of this code section. Allowing occupancy of a structure, for which a person or company holds a building permit prior to or without a valid Certificate of Occupancy (temporary or final) shall be deemed a violation of this code section and no future permits shall be issued to any person or company who has outstanding violations of this code or any other laws or ordinances of the City.
5. Add the following to Section 109.2 Schedule of Permit Fees with the following language:
Permit fees will be derived from the City of Waukee Fee Schedule adopted on an annual basis.
6. Add the following to Section R109.3:
7. The Building Valuation will be derived from the construction costs for the total work submitted by the contractor, or the most current Building Valuation Data Schedule published by the International Code Council (ICC). Submitted contractor valuation shall not be less than derived valuation through ICC.
Published data is utilized by the Administrative Official in an effort to maintain consistency and fairness for permit fee calculations. It is not intended to reflect actual taxable value.
8. Delete Section 308.5.4 and replace with the following:
308.5.4 Eight or fewer persons receiving care in a dwelling unit. A facility such as the above within a dwelling unit and having eight or fewer persons receiving custodial care shall be classified as a Group R-3 occupancy or shall comply with the International Residential Code.
Exception: Day care facilities that provide custodial care for 16 or fewer persons for less than 24 hours per day in a single family dwelling, and where registered with the Sate of Iowa Department of Human Services as a child development home on or before January 1, 2017, are permitted to comply with the International Residential Code.
9. Delete Section 310.4.1 and replace with the following:
310.4.1 Care Facilities Within A Dwelling. Care facilities within a dwelling shall adhere to Section 308.5.4
10. Delete Code Section: IBC 419.1 and replace with the following language:
11. 419.1 General. A live/work unit shall comply with Section 419.1 through 419.9.
12. Exceptions:
1. Dwelling or sleeping units that include an office that is less than 10 percent of the area of the dwelling unit are permitted to be classified as dwelling units with accessory occupancies in accordance with Section 508.2.
2. Detached one- and two-family dwellings and townhouses that include an office that is less than 20 percent of the area of the dwelling unit and constructed in accordance with the International Residential Code are not required to comply with Sections 419.1 through 419.9.
13. Amend Code Section: IBC 419.1.1 Item #3 to contain the following language:
14. The nonresidential area function shall be limited to floors of the live/work unit with exit at the 1st story or a basement walkout of the live/work unit.
15. Amend Code Section: IBC 419.2 to include Exception #2 with the following language:
16. 2. Live/work units located within detached one- and two-family dwellings and townhomes may be constructed in accordance with the International Residential Code.
17. Amend Section 423.4 to delete entire section including Subsections 423.4.1 and 423.4.2 and replace with the following language:
423.4 Group E Occupancy. In areas where the shelter design wind speed for tornadoes is 250 mph in accordance with Figure 304.2(1) or ICC 500, all Group E occupancies with a program occupancy load of 50 or more shall have a storm shelter constructed in accordance with Chapters 1 through 5 and 8 of ICC 500.
Exceptions:
1. Group E day care facilities.
2. Group E occupancies accessory to place of religious worship.
3. Buildings meeting the requirements for shelter design in ICC 500.
4. Accessory structures to existing Group E sites where the occupancy classification of said structures are classified as Groups A-5 and U.
423.4.1 Required Occupant Capacity. The required occupant capacity of the storm shelter shall include all buildings classified as a Group E occupancy on the campus or site (whichever is larger) and shall be the greater of the following:
1. The total occupant load of the classrooms, vocational rooms and offices in Group E occupancy.
2. The occupant load of any indoor assembly space that is associated with the Group E occupancy.
Exceptions:
1. Where a new building is being added on an existing Group E site, and where the new building is not of sufficient size to accommodate the required occupant capacity of the storm shelter for all of the buildings on-site, the storm shelter shall at a minimum accommodate the required capacity for the new building.
2. Where approved by the code official, the required occupant capacity of the shelter shall be permitted to be reduced by the occupant capacity of any existing storm shelters on the campus or site.
423.4.2 Location. Storm shelters shall be located within the buildings they serve, or shall be located where the maximum distance of travel from not fewer than one exterior door of each building to a door of the shelter serving that building does not exceed 1,000 feet.
The installation of portable buildings for utilization on the campus or site for educational purposes is considered new construction and classified as Group E occupancies.
Exception: existing schools undergoing alterations, additions, or construction of new accessory buildings.
20. Delete Code Section: IBC 502.1 (Correlation IFC 505.1) and replace with the following language:
502.1 Address Identification. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall be black or white and shall contract with their background. Where required by the fire code official, address numbers shall be provided in greater dimension or additional approved locations to facilitate emergency response. Address numbers shall be Arabic numbers or alphabetical letters. Number and letters shall be a minimum height and minimum stroke width as dictated by Table 502.1. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole, or other sign or means shall be used to identify the structure. Address numbers shall be maintained.
Table 502.1
Minimum Height and Stroke Width
Distance From the Centerline of the Public Way (ft) | Minimum Height (in) | Minimum Stroke Width (in) | ||
Less than 100 | 4 | ½ | ||
100 | 199 | 6 | ¾ | |
200 | 299 | 8 | 1 | |
For each additional 100 | Increase 2 | Increase 1/2 |
a Exterior suite identification, minimum height shall be four inches and stroke width shall be ½ inch.
b Interior suite identification, minimum height shall be two inches and stroke width shall be ¼ inch.
21. Amend IBC 707.5 to add Exception 3 with the following language:
22. 3. Shafts required to be constructed as per Section 713.3.2 having exterior walls that are not required to be fire rated per Section 707.4 shall be permitted to be constructed of materials permitted by the building type of construction so long as a complete noncombustible separation of two hours is provided between the shaft and adjoining structure. In addition, the provisions of Section 1023.7 shall be met.
23. Delete IBC 713.3 and replace with the following language:
24. 713.3 Materials. Shaft enclosures shall be of material and constructed in accordance with Sections 713.3.1 and 713.3.2.
25. Add code Section IBC 713.3.1 with the following language:
26. 713.3.1 One Hour Shaft Enclosures. Shafts that are allowed to have a fire resistance rating of one hour or less are allowed to be constructed of materials permitted by the building type of construction.
27. Add code Section IBC 713.3.2 with the following language:
28. 713.3.2. Two Hour Shaft Enclosures. Shafts that are required to have a fire resistance rating of two hours or more serving interior exit stairs or interior exit ramps shall be constructed of concrete or masonry for Types III, IV, and V construction. Interior exit stairs or interior exit ramps in Type I and II construction and all other shafts that are required to have a fire resistance rating of two hours or more shall be constructed of non-combustible materials.
29. Modify IBC Section 716.2.6.1 to add the following language after the last sentence:
30. Automatic, self-closing, UL listed hinges may only be installed on the dwelling room entry door.
31. Add Section 902.1.1.1 (Correlation 901.4.6.1) to include the following language:
32. 902.1.1.1 Fire Sprinkler Riser Room. A fire sprinkler riser room shall be separated from the electrical room. The riser room shall have no electrical panels, devices, or apparatus inside the room other than the outlets or support equipment (lighting, air compressor, and heater) required for the use of the fire sprinkler system and/or the alarm panel. The sprinkler riser room shall not be accessed from the electrical room, but the electrical room may be accessed from the fire riser room.
33. Add new code Section IBC 902.1.5 (Correlation IFC 901.4.6.5 DD) to include the following language:
34. 902.1.5 Temperature Sensor. Provide a low temperature sensor in the fire sprinkler riser room. Low temperature sensor shall be monitored to prevent freezing.
35. Delete Section 903.2 and replace with the following:
903.2 Where required. Approved automatic sprinkler systems in new buildings and structures shall be provided in the locations described in Sections 903.2.1 through 903.2.12. consistent with adopted amendments to the 2018 International Fire Code for the City of Waukee.
1. An approved automatic fire extinguishing system is required if the gross square footage of a building is equal to or greater than described in Sections 903.2.1 through 903.2.12.
2. The square footage used for calculating total “gross square footage” of a building or structure shall be measured using the outside dimensions of the total building or structure to include attached or detached buildings or structures.
3. To exempt detached buildings or structures from the total gross square footage from meeting the requirements to have fire sprinkler systems installed, the buildings or structures per legal lot or contiguous lots under common ownership, must be separated by 20’ and have one-hour rated exterior walls on both buildings or structures so as not to have the combined total of their gross square footage applied to this section of the code.
4. For the purposes of Section 903.2, “fire separations” shall not be permitted to reduce the total gross square footage of a building or area for the purpose of calculating the fire sprinkler square footage requirements.
5. For the purposes of Section 903.2, “story” shall be defined as any level of a structure, whether above or below grade capable of occupancy.
6. Additions to buildings or structures shall comply with all of the requirements of Section 903.2 of this code for new buildings or structures. The entire building or structure, existing and proposed additions, shall comply with all of the requirements of the fire sprinkler Section 903.2 of the fire code for new buildings and structures, when the total of all the additions to the building or structure made exceeds 25 percent of the gross area of the building or structure.
7. When a building is used for more than one occupancy purpose or use, the entire building shall meet the requirements of the fire sprinkler Section 903.2 of the fire code based on the requirements for the most restrictive occupancy group as defined in Chapter 2 of the International Fire Code, 2018 Edition.
Exception: Spaces or areas in telecommunications buildings used exclusively for telecommunications equipment, associated electrical power distribution equipment, batteries and standby engines, provided those spaces or areas are equipped throughout with an automatic smoke detection system in accordance with Section 907.2 and are separate from the remainder of the building by not less than one-hour fire barriers constructed in accordance with Section 707 of the International Building Code or not less than two-hour horizontal assemblies constructed in accordance with Section 711 of the International Building Code, or both.
36. Delete Section 903.2.11.1.3 and replace with the following:
903.2.11.1.3 Basements. Where any portion of a basement is located more than 75 feet from openings required by Section 903.2.11.1, the basement shall be equipped throughout with an approved automatic sprinkler system.
37. Add Section 903.3.1.1.3 with the following language:
38. 903.1.1.3 Sprinkler Installed Under Exterior Projections. A canopy covering a door that is required to be marked as an exit shall be required to have fire sprinklers installed outside that door if the canopy extends more than four feet out from the door and is 12 feet or less in height from the ground regardless of whether the canopy is combustible or non-combustible. Canopies that have vehicle access under them with door opening shall be required to have fire sprinklers installed under the total canopy regardless of whether the canopy is combustible or non-combustible.
39. Delete Section 903.4.2 and replace with the following:
903.4.2 Alarms. An approved weather proof audible device suitable for outdoor use with 110 candela visual signal shall be connected to every automatic sprinkler system. Such sprinkler water-flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Alarm devices shall be provided on the exterior of the building in an approved location. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system.
40. Add the following Section 905.3.9:
905.3.9 Building Footprint and Access. Where the most remote portion of a floor or story is more than 400 feet from a hose connection or Fire Department access road, the fire code official is authorized to require standpipes to be provided in approved locations. Class I manual standpipes shall be allowed.
41. Add the following Section 907.1.4:
907.1.4 FACP (Fire Alarm Control Panels)
Each building shall have no more than 1 FACP.
Installation of fire alarm panel shall not exceed six feet in height measured from the floor to the top of the unit.
Exception: Suppression system releasing panels are not required to meet the height requirement or the limitation in the number of panels.
42. Amend Section 907.2 to add the following exception:
Exception:
3. Fire Area and Occupant Load Amendments, refer to 2018 IFC amendments.
43. Delete Section 907.6.6 and replace with the following:
907.6.6 Monitoring. Fire alarm systems required by this chapter or by the International Building Code shall be monitored at a central station approved and listed under UL 827 in accordance with NFPA 72.
Exception: Monitoring station is not required for:
1. Automatic sprinkler and fire alarm systems in one- and two-family dwellings.
44. Delete Section 910.2.1 and replace with the following:
910.2.1 Group F-1 or S-1. Smoke and heat vents installed in accordance with Section 910.3 or a mechanical smoke removal system installed in accordance with Section 910.4 shall be installed in buildings and portions thereof used as a Group F-1 or S-1 occupancy having more than 30,000 square feet (2,787 square meters) of undivided area. In occupied portions of a building equipped throughout with an automatic sprinkler system in accordance with 903.3.1.1, where the upper surface of the story is not a roof assembly, a mechanical smoke removal system in accordance with Section 910.4 shall be installed.
Exception: Group S-1 aircraft repair hangars.
45. Delete Section 1008.3.3 to add the following locations with sequential numbering:
5. Public restrooms containing more than one water closet/urinal or that are accessible.
6. Meeting and conference rooms with an area greater than 400 square feet.
7. Classrooms in an E occupancy with an area greater than 400 square feet.
46. Amend Section 1009.2 to add the following:
11. Components of exterior walking surfaces shall be concrete, asphalt, or other approved hard surface.
47. Add Section 1010.1.6.1 with the following language:
1010.1.6.1. For landings required by Section 1010.1.5 to be at the same elevation on each side of the door, exterior landings at doors shall be provided with frost protection.
48. Amend Section 1010.1.9.1 to add the following:
Thumb turn locks shall not be allowed.
49. Add the following Section 1013.1.1:
1013.1.1 Additional Exit Signs. Exit signs may be required at the discretion of the Administrative Official to clarify an exit or exit access.
50. Delete Sections 1013.5 and 1013.6 including 1013.6.1, 1013.6.2 and 1013.6.3.
51. Add the following Section 1028.5.1:
1028.5.1 Components of exterior walking surfaces shall be concrete, asphalt, or other approved hard surface.
52. Add the following Section 1030.5.3:
1030.5.3 Window Well Drainage. All window wells shall be provided with approved drainage.
53. Modify code Section IBC 1301.1 and replace with the following language:
54. Section 1301.1 Scope. The provisions of the International Energy Code as currently adopted and amended by the Iowa State Building Code Bureau shall apply to all matters governing the design and construction of buildings for energy efficiency. Administration shall be as prescribed in Chapter 1 of the currently State adoption of the IECC and these regulations shall be known as the Waukee Energy Code.
55. Amend Section 1608.2 to add the following:
For purposes of determining snow loads, the minimum ground snow load for design purposes shall be 30 pounds per square foot. Subsequent increases or decreases shall be allowed as otherwise provided in this code, except that the minimum allowable flat roof snow load may be reduced to not less than 80 percent of the ground snow load.
56. In Section 1609.1.1 add the following:
For purposes of determining wind loads, the minimum basic wind speed shall be considered as 115 miles per hour; except when referenced documents are based on fastest mile wind velocities, Table 1609.3(1) shall be used.
57. Add the following to Section 1807.1 Foundation Retaining Walls for Group R Occupancies:
1. Scope. Notwithstanding other design requirements of Chapters 18, 19, and 21 of the International Building Code, foundation retaining walls for Group R occupancies of Type V construction may be constructed in accordance with this section, provided that use or building site conditions affecting such walls are within the limitations specified in this section.
2. Specifications. General specifications for such foundation retaining walls shall be as follows:
Table – Foundation Walls for Conventional Light Frame Construction
Height of Foundation Wall (Net measured from top of basement slab to top of foundation wall)* | Thickness of Foundation Walls | Reinforcement Type and Placement Within Foundation Wall** | Reinforcement Type and Placement Within Foundation Wall** (maximum 12’ span between corners and supporting cross walls) | Type of Mortar | ||
Unit | ||||||
Gross | Net | Concrete | Masonry | Concrete Y2” horizontal bars, placement in the middle, and near the top and bottom – Y2” bars @ 6’ max. vertically | Masonry | Masonry Type M or S. Grout and Mortar shall meet provisions of Chapter 21 IBC |
8 | 7’ 8” | 7 Y2” | 8” | 0..075 square inch bar 8’ o.c. vertically in fully grouted cells. If block is 12” nominal thickness, may be unreinforced. | ||
9 | 8’8” | 8” | See Chapter 18 IBC | Y2” bars 2’ o.c. horizontally and 20” | See Chapter 18 IBC | Same as above |
10 | 9’ 8” | 8” | See Chapter | See Chapter 18 IBC | Same as above | |
18 IBC | (5./8” bars 2’ o.c. horizontally and 30” vertically o.c.) | |||||
*Concrete floor slab to be nominal 4”. If such floor slab is not provided prior to backfill, provide 1) 36” embedded in the footing @ maximum 7’ O.C. spacing and/or 2) full depth nominal 2” depth x 4” width keyway in footing. **All reinforcement bars shall meet ASTM A6175 grade 40 minimum and be deformed. Placement of center of wall and meet the provisions of Chapters 18,19, and 21 of the International Building Code. | ||||||
NOTE: Cast in place concrete shall have a compressive strength of 3,000 lbs @ 28 days. Footings shall reinforcement of minimum 2 – Y2” diameter rebar throughout. Placement of reinforcement and requirements of Chapter 19 of the International Building Code. | ||||||
NOTE: Material used for backfilling shall be carefully placed granular soil of average or high permeability and drained with an approved drainage system as prescribed in Section 1805.4 of the International Building Code. When containing a high percentage of clay, fine silt, or similar materials of low permeability or expansive soils, or where backfill materials are not drained, or an unusually high surcharge is to be placed adjacent to the wall, a designed wall shall be required. | ||||||
NOTE: Foundation plate or sill anchorage shall be installed in accordance with the respective codes as applicable. | ||||||
58. Replace Table 1809.7 with the following:
TABLE 1809.7
FOUNDATIONS FOR STUD BEARING WALLS
Number of Stories | Thickness of Foundation Walls Unit Concrete Masonry | Minimum Width of Footing (inches) | Thickness of Footing (inches) | Minimum Depth of Foundation Below Natural Surface of Ground and Finish Grade (inches) | |
1 | 8 | 8 | 16 | 8 | 42 |
2 | 8 | 8 | 16 | 8 | 42 |
3 | 10 | 10 | 18 | 12 | 42 |
[The next page is 1085]
1.