SECTION P-1103 TRAPS
P-1103.1 Main trap. Leaders and storm drains connected to a combined sewer shall be trapped. Individual storm water traps shall be installed on the storm water drain branch serving each conductor, or a single trap shall be installed in the main storm drain just before its connection with the combined building sewer or the public sewer. A single hooded catch basin located within the property line shall be the equivalent of a building (house) trap for the connection to a street combined sewer. Leaders and storm drains connected to a building storm sewer shall not be required to be trapped.
* * *
P-1103.4 Cleanout. A cleanout shall be installed on the building side of the trap and shall be provided with access. A cleanout or a building storm sewer house trap shall be required on a dedicated storm sewer system where the building storm sewer connects at the curb.
* * *