SECTION P-606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SUPPLY SYSTEM
* * *
P-606.7 Labeling of water distribution supply pipes in bundles. Where water distribution supply piping is bundled at installation, each pipe in the bundle shall be identified using stenciling or commercially available pipe labels. The identification shall indicate the pipe contents and the direction of flow in the pipe. The interval of the identification markings on the pipe shall not exceed 25 feet (7620 mm). There shall be not less than one identification label on each pipe in each room, space or story.