15.04.120: MANUFACTURED/MOBILE HOME STANDARDS, RULES AND REGULATIONS:
   A.   Compliance With Statutory Requirements: Nevada Revised Statutes 489.251 directs that regulations be adopted by the state of Nevada pertaining to safety standards for installation, support and tie down of manufactured/mobile homes or commercial coaches and to inspection of plumbing, heating, cooling, fuel burning and electrical systems connections.
   B.   Adopted: The Nevada Administrative Code, chapter 489 is adopted.
   C.   Compliance With Development Code: Manufactured/mobile homes shall comply with all requirements as set forth in the Pershing County Development Code, chapter 308, fabricated housing.
      1.   Runners/footings shall be installed per Pershing County minimum requirements as determined by the Pershing County building official.
      2.   Perimeter foundations shall be installed to the manufacturer's requirements and the 2003 International Residential Code.
      3.   A minimum of sixteen inches (16") shall be required from the bottom of the chassis frame member to the top of the footing (runner).
      4.   All requirements of chapter 308 of the Pershing County Development Code, fabricated housing, regarding conversion to real property will be complied with.
      5.   The disconnect for the electric service shall be within thirty feet (30') of the home, on a pedestal that is a minimum of four feet (4') in height.
   D.   Permit Fees:
 
Manufactured/mobile home setup permits (includes all utility inspections)
$125.00
Perimeter foundation
150.00
Runners
60.00
 
(Ord. 348, 2021: Ord. 220, 2005)