Skip to code content (skip section selection)
Compare to:
New York City Overview
The New York City Charter
The New York City Administrative Code
The Rules of the City of New York
THE RULES OF THE CITY OF NEW YORK
Title 1: Department of Buildings
Chapter 1: Material and Equipment Application Procedures [Repealed]
Chapter 2: Boiler Inspections [Repealed]
Chapter 3: Vacant and Unguarded Buildings
Chapter 4: Certificates of Occupancy, Live Loads and Occupancy Loads
Chapter 5: Concrete
Chapter 6: Cranes [Repealed]
Chapter 7: Installation and Maintenance of Vent Damper Devices in Existing Boilers and Furnaces [Repealed]
Chapter 8: Demolition [Repealed]
Chapter 9: Rigging Operations [Repealed]
Chapter 10: Drums for Derrick Load and Boom Hoists
Chapter 11: Elevators, Escalators, Personnel Hoists and Moving Walks
Chapter 12: Emergency Power Systems [Repealed]
Chapter 13: Adjudications [Repealed]
Chapter 14: Fees [Repealed]
Chapter 15: Fire Protection
Chapter 16: Inspection of Existing Structures During Construction Operations
Chapter 17: Testing Laboratories and Testing Services
Chapter 18: Resistance to Progressive Collapse Under Extreme Local Loads
Chapter 19: Master Plumbers and Licensed Fire Suppression Piping Contractors
Chapter 20: Piping Systems
Chapter 21: Plans
Chapter 22: Pressure Tanks
Chapter 23: Noncommercial Greenhouses
Chapter 24: Refuse Chutes and Refuse Rooms
Chapter 25: Climber and Tower Crane Riggers [Repealed]
Chapter 26: Safety of Public and Property During Construction Operations. [Repealed]
Chapter 27: Signs
Chapter 28: Smoke Detecting Devices and Systems and Carbon Monoxide Detecting Devices and Systems [Repealed]
Chapter 29: Sprinkler Systems
Chapter 30: Storage of Certain Waste Materials
Chapter 31: Suspension, Revocation Or Limitation of Registration [Repealed]
Chapter 32: Walls [Repealed]
Chapter 33: Exemptions from Civil Penalties [Repealed]
Chapter 34: Electrical Code Rules
Chapter 35: Electrical Inspection
Chapter 36: Electrical Contractors
Chapter 37: Reference Standards [Repealed]
Chapter 38: Ventilation
Chapter 39: Cooling Towers and Evaporative Condensers
Chapter 40: Installation and Maintenance of Gas-Fueled Water and Space Heaters in All Portions of Dwellings Used or Occupied for Living Purposes
Chapter 41: Venting of Gas Water Heaters and Other Gas Appliances In Multiple Dwellings
Chapter 42: Entrance Doors, Locks and Intercommunication Systems
Chapter 43: Installation of Security Items in Multiple Dwellings
Chapter 44: Exemptions from Filing Requirements [Repealed]
Chapter 45: Building Permit Application Procedures
Chapter 46: Authorized Representatives
Chapter 47: Licensed Oil-Burning Equipment Installers
Chapter 48: Construction Superintendents [Repealed]
Chapter 49: Outdoor Signs
Chapter 50: Distributed Energy Resource Standards
Chapter 51: Dormitories
Chapter 52: Notification to the Department of Commencement of Work Pursuant to an Earthwork Permit
Chapter 100: [Administration; Enforcement; Maintenance of Buildings; Licensing; Miscellaneous Provisions]
Chapter 300: Use and Occupancy Classification
Chapter 400: Special Detailed Requirements Based on Use and Occupancy [Repealed]
Chapter 900: Fire Protection Systems
Chapter 1000: Means of Egress
Chapter 1100: Accessibility
Chapter 3000: Elevators and Conveying Systems
Chapter 3300: Safeguards During Construction and Demolition
Chapter 3500: Referenced Standards
Chapter 3600: Appendices
Chapter 4000: Electrical Code
Chapter 5000: New York City Energy Conservation Code
Chapter 6000: Fuel Gas Code
Chapter 7000: Mechanical Code
Chapter 8000: New York City Plumbing Code
Chapter 9000: Zoning
Title 2: Board of Standards and Appeals
Title 3: Fire Department
Title 6: Department of Consumer and Worker Protection
Title 9: Procurement Policy Board Rules
Title 12: Franchise and Concession Review Committee
Title 15: Department of Environmental Protection
Title 16: Department of Sanitation
Title 17: Business Integrity Commission
Title 19: Department of Finance
Title 20: Tax Appeals Tribunal
Title 21: Tax Commission
Title 22: Banking Commission
Title 24: Department of Health and Mental Hygiene
Title 25: Department of Mental Health and Retardation [Repealed]
Title 28: Housing Preservation and Development
Title 29: Loft Board
Title 30: Rent Guidelines Board
Title 31: Mayor's Office of Homelessness and Single Room Occupancy
Title 34: Department of Transportation
Title 35: Taxi and Limousine Commission
Title 38: Police Department
Title 38-A: Civilian Complaint Review Board
Title 39: Department of Correction
Title 40: Board of Correction
Title 41: Department of Juvenile Justice
Title 42: Department of Probation
Title 43: Mayor
Title 44: Comptroller
Title 45: Borough Presidents
Title 46: Law Department
Title 47: Commission on Human Rights
Title 48: Office of Administrative Trials and Hearings (OATH)
Title 49: Department of Records and Information Services
Title 50: Community Assistance Unit
Title 51: City Clerk
Title 52: Campaign Finance Board*
Title 53: Conflicts of Interest Board
Title 55: Department of Citywide Administrative Services
Title 56: Department of Parks and Recreation
Title 57: Art Commission
Title 58: Department of Cultural Affairs
Title 60: Civil Service Commission
Title 61: Office of Collective Bargaining
Title 62: City Planning
Title 63: Landmarks Preservation Commission
Title 66: Department of Small Business Services
Title 67: Department of Information Technology and Telecommunications
Title 68: Human Resources Administration
Title 69: Department of Aging
Title 70: In Rem Foreclosure Release Board
Title 71: Voter Assistance Commission
Title 72: Office of Emergency Management
Title 73: Civic Engagement Commission
Title 74: Community Hiring
Chapter 5: Concrete
§ 5-01 Conveyance by Pumping Methods [Repealed]
(Repealed City Record 11/7/2022, eff. 12/7/2022)
§ 5-02 Licensing of Concrete Testing Laboratories.
   (a)   General.
      (1)   Each laboratory shall have in responsible charge a Director who shall be professionally qualified and who shall personally supervise all technical functions of the laboratory relating to testing of concrete and concrete materials. Sections 27-605 and 27-607 of the Administrative Code require that a licensed Professional Engineer or a Registered Architect supervise the testing of materials and the inspection of concrete construction.
      (2)   All technicians shall be qualified to perform all tests they may be required to conduct under the supervision of the Director.
      (3)   The laboratory shall annually furnish to the Department of Buildings a list of all personnel who are supervising and performing tests and their qualifications. Note: 1 RCNY § 5-02(b)(6) shall also be complied with.
      (4)   The laboratory shall furnish to the Department of Buildings a list of all the equipment used to perform tests on concrete and concrete materials.
      (5)   The laboratory shall request and have an inspection made of its procedure and equipment by the "Cement and Concrete Reference Laboratory" whenever the "Cement and Concrete Reference Laboratory" is inspecting laboratories in this area on its cyclical tour of inspection. These inspections shall be made at the cost and expense of the laboratory seeking a license. A copy of the inspection report shall be promptly submitted to the Department of Buildings.
      (6)   The laboratory shall correct within 10 days any condition ordered by the Department of Buildings which in its judgment may adversely affect the results of any test.
      (7)   A license shall be issued to each applicant upon proof of compliance with these rules and upon payment of a fee of one hundred dollars ($100).
      (8)   The annual renewal fee shall be fifty dollars ($50).
      (9)   A violation of any of these rules or the falsifying or misrepresentation of any fact in any required report shall constitute cause for revocation or suspension of the license by the Commissioner, after a hearing upon prior notice of at least ten calendar days. However, notwithstanding the foregoing, when the public safety may be imminently jeopardized or when false report has been made, the Commissioner shall have the power, pending a hearing and determination of charges, to forthwith suspend the license for a period not exceeding five working days. The presence of batch tickets at a plant filled in on any day other than the day the specific batch is to be delivered to the construction site, whether signed or unsigned, shall constitute a false report.
      (10)   All reports submitted by the laboratory shall bear its name and its license number.
      (11)   Renewal of licenses or certificates of qualification, heretofore issued, and issuance of new licenses shall be conditioned upon and subject to the provisions of §§ 26-131 through 26-139 and 26-200 through 26-204 of the Administrative Code.
      (12)   The laboratory shall display a copy of its license on its premises.
      (13)   The Director shall furnish all of his employees an identification card with a photograph of the employee affixed thereto.
      (14)   The Director shall maintain a daily record of the activities of all of his employees, indicating the time of departure to and return from batch plant or construction site inspections, the construction project to which the employee is assigned, and the batch plant visited. This record shall be maintained for 2 years and shall be made available to the department personnel.
   (b)   Personnel.
      (1)   The Director shall be qualified by virtue of education and experience to supervise all tests of concrete and concrete materials conducted by the laboratory. He shall be qualified to practice Professional Engineering or Architecture in the State of New York.
      (2)   All technicians performing tests on the chemical composition of cement shall be qualified analytical chemists.
      (3)   All other technicians, field personnel, and all personnel having direct supervision of technical staff shall be qualified by education and experience to take samples and perform required tests. Qualifying education and experience may include a degree in engineering, suitable experience in concrete construction, suitable training in concrete industry sponsored programs and the like.
      (4)   Satisfactory proof of such qualifications for concrete field testing technicians shall include certification resulting from the ability to pass a qualification test following the guidelines of the American Concrete Institute as set forth in ACI publication CP-2(82).
      (5)   All concrete field testing technicians shall be qualified pursuant to 1 RCNY § 5-02(b)(4) on or before July 1, 1985.
      (6)   The Department of Buildings shall annually publish in The City Record, on or before the first of July, a listing of concrete field testing technicians qualified pursuant to 1 RCNY § 5-02(b)(4).
      (7)   The Director shall submit to the department an affidavit that all technicians and field personnel are qualified to perform their designated tasks and shall keep on the premises a record of the qualifications of all personnel, which shall be made available to the department upon request.
   (c)   Reports. Reports shall be presented in a form acceptable to the Department of Buildings.
   (d)   Tests.
      (1)   The following specifications of the American Society for Testing and Materials (ASTM) shall be considered as part of these rules:
C29-78
Test for Unit Weight and Voids in Aggregate.
C31-85
Methods of Making and Curing Concrete Test Specimens in the Field.
C39-84
Test Method for Compressive Strength of Cylindrical Concrete Specimens.
C40-84
Test Method for Organic Impurities in Fine Aggregates for Concrete.
C42-84a
Methods of Obtaining and Testing Drilled Cores and Sawed Beams of Concrete.
C70-79
Standard Method of Test for Surface Moisture in Fine Aggregate.
C88-83
Test Method for Soundness of Aggregates by Use of Sodium Sulfate or Magnesium Sulfate.
C109-86
Test Method or Compressive Strength of Hydraulic Cement Mortars (Using 2-inch or 50-mm cube Specimens).
C114-85
Method of Chemical Analysis of Hydraulic Cement.
C115-79b
Standard Method of Test for Fineness of Portland Cement by the Turbidimeter.
C117-84
Test Method for Material Finer than 75-um (No. 200) Sieve in Mineral Aggregates by Washing.
C127-84
Test Method for Specific Gravity and Absorption of Coarse Aggregate.
C128-84
Test Method for Specific Gravity and Absorption of Fine Aggregate.
C136-84a
Method for Sieve Analysis of Fine and Coarse Aggregates.
C138-81
Standard Method of Test for Unit Weight, Yield and Air Content (Gravimetric) of Concrete.
C143-78
Test Method for Slump of Portland Cement Concrete.
C151-84
Test Method for Autoclave Expansion of Portland Cement.
C172-82
Method of Sampling Fresh Mixed Concrete.
C173-78
Standard Method of Test for Air Content of Freshly-Mixed Concrete by the Volumetric Method.
C183-83a
Method of Sampling and Acceptance of Hydraulic Cement Mortar.
C184-83
Test for Fineness of Hydraulic Cement by the 150-um (No. 100) and 75-um (No. 200) Sieves.
C187-86
Test Method for Normal Consistency of Hydraulic Cement.
C190-85
Test Method for Tensile Strength of Hydraulic Cement Mortars.
C191-82
Test Method for Time of Setting of Hydraulic Cement by Vicat Needle.
C192-81
Method of Making and Curing Concrete Test Specimens in the Laboratory.
C204-84
Test Method for Fineness of Portland Cement by Air Permeability Apparatus.
C230-83
Specification for Flow Table for Use in Tests of Hydraulic Cement.
C231-82
Standard Method of Test for Air Content of Freshly-Mixed Concrete by the Pressure Method.
C260-86
Specification for Air-Entraining Admixtures for Concrete.
C266-77
Test for Time of Setting of Hydraulic Cement by Gillmore Needles.
C494-86
Specification for Chemical Admixtures for Concrete.
C131-81
Resistance to Abrasion of Small-Size Coarse Aggregate by Use of Los Angeles Machine.
C535-81
Resistance to Degradation of Large-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine, Test for
C803-82
Penetration Resistance to Hardened Concrete, Test for
E4-83a
Practices for Load Verification of Testing Machines.
 
      (2)   All testing of cement shall be conducted in accordance with the Standard Specifications of the American Society for Testing and Materials (ASTM).
   (e)   Curing and testing of concrete specimens.
      (1)   The laboratory shall be equipped with a suitable size enclosed room for the curing of all concrete test specimens. It shall be of such size that specimens can be easily handled during storage and preparation for testing. The room shall be equipped with the necessary equipment to maintain a temperature of 73.4 degrees 3.0 degrees F. at all times, as per ASTM C 192. The room also shall be equipped to maintain a relative humidity of 95 percent plus in order that the specimens will be maintained in a moist condition in which free water is on the surface at all times. The test specimen shall not be exposed to a stream of running water.
      (2)   The laboratory shall have equipment for determining relative humidity and temperature of the room and recording devices to monitor them.
      (3)   The laboratory shall be equipped with a power operated testing machine with a variable speed control. It shall be of sufficient capacity and capable of applying load without shock at a rate of loading prescribed in § 4(b) of ASTM C 39.
      (4)   The testing machine shall be equipped with two steel bearing blocks with hardened faces, one of which is a spherically seated block that normally will bear on the upper surfaces of the specimen and the other a plain rigid block on which the specimen will rest. The bearing faces of these blocks used for compression testing of concrete shall have a Rockwell hardness of not less than 55 HRC. The bearing faces shall be at least as large and preferably slightly larger than the surface of the specimen to which the load is applied. The bearing faces when new shall not depart from a plan by more than 0.0005-inch at any point and they shall be maintained within a permissible variation limit of 0.001-inch. The movable portion of the spherically seated block shall be designed so that the bearing face can be rotated freely and tilted through small angles in any direction.
      (5)   The machine, if hydraulic, shall be equipped with a dial gauge having a sufficient diameter to allow the increments of load to be read within plus or minus 1/2 percent of the load being applied.
      (6)   The machine shall show a certificate of calibration or verification within the time limits set by requirements of ASTM E 4. If any major repairs have been made on the testing machines, the machine shall be re-calibrated.
   (f)   Equipment. The laboratory shall provide and maintain in proper working condition the following equipment as a minimum requirement:
      (1)   Necessary for concrete mix designs:
         (i)   Concrete mixer
            (A)   1 1/2 cubic foot capacity
            (B)   3 1/2 cubic foot total drum volume
         (ii)   Slump cone 8-inches in diameter at the base and 4-inches at the top of a height of 12-inches and conforming to ASTM C 143.
         (iii)   A tamping rod consisting of a round, straight steel rod 5/8-inch in diameter.
         (iv)   Cylindrical metal measures of 1/2 cubic foot and a cubic foot capacity conforming to the requirements of ASTM C 138.
         (v)   A sturdy, flat plate about 15-inches square for striking off the concrete in the measure.
         (vi)   Appropriate air meter.
         (vii)   Necessary scoops, wood floats, trowels.
         (viii)   A balance or scale sensitive to 0.1 pound, having a capacity of not less than 100 pounds.
      (2)   Necessary equipment for preparation of concrete test cylinders:
         (i)   For compression tests:
            (A)   Capping plates for cement or plaster caps. Plate glass at least 1/4-inch thick, or machined metal plates at least 1/2-inch thick or polished stone plates of suitable materials, such as granite or diabase and at least 3-inches thick. A capping plate shall be at least l-inch greater in diameter than the specimen.
            (B)   Capping plates for use with mixtures of sulphur and granular materials, or similar materials and dimensions, recessed to retain the molten mixture.
            (C)   The surface of any capping plate shall not depart from a plane by more than .002-inch in the diameter of the specimen.
            (D)   Straight edge and feeler gauges to check planeness of capping plates and caps.
            (E)   Calipers and rule for checking size of cylinders.
            (F)   Controlled temperature melting pot if sulphur mixtures are to be used. Mixing pans, scoops, spoons, trowels, spatulas, etc., if cement or plaster caps, are to be used.
            (G)   Appropriate grinding equipment may be substituted for the capping equipment.
         (ii)   Materials required:
            (A)   For cement or plaster caps, any of the following:
                  Type I Portland Cement
                  High Alumina Cement (Lumnite)
                  Type III Portland Cement
                  High strength gypsum plasters such as:
                  Hydrostone and Hydrocal White (Note: Plaster of Paris is not satisfactory).
            (B)   For sulphur caps either of the following: Laboratory prepared mixtures of sulphur and granular materials. Proprietary mixtures such as: Vitroband, Leadite, Cylcap, etc. (Note: See ASTM C 1982 for limitations of various type caps).
      (3)   Necessary for analysis of fine and coarse aggregates:
         (i)   Square or round mesh sieves, Pan Nos. 200, 100, 50, 30, 16, 8, 4, 1/4-inch, 3/8-inch, 1/2-inch, 3/4-inch, 1-inch, 1 1/2-inches, 2-inches, 3-inches, 3 1/2-inches, No. 12.
         (ii)   Sieve shaking equipment.
         (iii)   Scales:
            (A)   Gram scale sensitive to at least 0.1 gram.
            (B)   Gram scale with at least 5,000 gram capacity and sensitive to 1 gram.
            (C)   Pound scale sensitive to 1/4-ounce.
            (D)   Steel brush to brush sieves.
            (E)   Oven-heat continuously between 221 degrees and 230 degrees F.
            (F)   Containers for holding solutions.
            (G)   Perforated containers for immersing aggregates in solutions - wire baskets.
            (H)   Calibrated Volumetric (milliliters) graduate, 500 milliliters capacity.
            (I)   Conical metal mold 1 1/2-inches diameter at top, 3 1/2-inches diameter at bottom, 2 7/8-inches high.
            (J)   Tamping rod - 12-ounces, having a flat circular tamping face 1-inch in diameter.
            (K)   Tamping rod - 5/8-inch diameter, 24-inches length.
            (L)   Cubic foot cylindrical measure either 1/2 cubic foot, 1/4 cubic foot, 1/3 cubic foot, 1/10 cubic foot or 1 cubic foot.
            (M)   500 milliliters flask.
            (N)   Thermometer - heats over 100 degrees C.
      (4)   Necessary for field testing and inspection:
         (i)   Thermometer, 0 degrees - 200 degrees F.
         (ii)   Scale, 100 lbs. capacity.
         (iii)   6-inch round by 12-inch long container.
         (iv)   Slump cone and 5/8-inch by 24-inch rod.
         (v)   Air meter.
         (vi)   Rule, 12-inches.
   (g)   Cement testing.
      (1)   Introduction. Cement testing shall be done in laboratories equipped to make the basic tests required for evaluating cement.
      (2)   Division into physical and chemical tests. These tests are divided into two parts, physical and chemical and all physical test specimens shall be prepared in a room or area where the temperature is controlled within the limits of 20 to 27.5 degrees C. and the humidity at not less than 50 percent.
      (3)   Physical test equipment:
         (i)   Analytical balance complete with calibrated weights.
         (ii)   Scale of 2,000 gram capacity accurate to 0.1 percent.
         (iii)   Wagner Turbidimeter or Blaine permeability apparatus calibrated with standard cement from the Bureau of Standards.
         (iv)   One 325 mesh sieve as well as 100, 50, 30 and 16 mesh sizes.
         (v)   Electrically driven mixer bowl and paddle.
         (vi)   Flow table and flow mould.
         (vii)   Trowel and tamper for cubes.
         (viii)   Cube moulds and sealing compound.
         (ix)   Autoclave, moulds and comparator with steel reference bar.
         (x)   Vicat apparatus and moulds.
         (xi)   Gilimore needles and glass plates for samples.
         (xii)   LeChatelier flask.
         (xiii)   Supply of graded Ottawa Sand.
         (xiv)   Glass graduates of 100, 150 and 200 ml. capacity.
         (xv)   Cylindrical measure of 400 ml.
         (xvi)   Straight edge and spatula.
         (xvii)   Calibrated testing machine of not less than 30,000 lbs., capacity equipped with spherically seated upper steel block of not more than 31/2 diameter.
      (4)   ASTM standard tests for cements. Standard tests for cements as required by ASTM are as follows:
            Fineness
            Soundness
            Time of setting
            Air content of mortar
            Compressive tests of 2-inch by 2-inch cubes.
      (5)   Chemical composition of cement:
         (i)   The laboratory shall be equipped with an analytical balance and standard weights, platinum and porcelain crucibles, curettes, pipettes, etc.
         (ii)   Distilled water and all reagents necessary for the determination of the oxides of silica, iron, aluminum, magnesium, sulphur, calcium, and insoluble residue by one of approved.
         (iii)   All tests shall be performed in a room equipped with fume chamber, gas burners, working benches, by a qualified analytical chemist.
         (iv)   Special tests such as the alkalies of sodium and potassium shall be made as outlined by the ASTM.
§ 5-03 Approval of Prequalified Concrete Mixes.
   (a)   Source of concrete mixes. Concrete proportioned according to prequalified mixes shall be produced only from batch plants, approved by the Commissioner pursuant to rules and regulations of the department.
   (b)   Mix designs not previously accepted. Each concrete producer or group of producers seeking approval of mix designs that have not been previously accepted by the Department shall file an application with the M.E.A. Division, Department of Buildings at the address provided in the City's website, http://www.nyc.gov, and shall furnish the following:
      (1)   A compilation of the proposed mix designs listing the batch weights, types of aggregates and other ingredients together with a numbering system that will provide identification of each mix for testing and recording purposes. Each compilation shall contain a title sheet upon which a master list of all the mixes shall be designated. Opposite each mix a space shall be provided for the signature of the examiner and the date of the approval of that particular mix. When a mix has been approved for use as a "PREQUALIFIED MIX," the examiner shall affix his signature and the date in the space provided, and then he shall affix the approval stamp of the Commissioner of Buildings.
      (2)   For each mix utilizing a different combination of aggregates, admixtures, cement type, water-cement ratio, etc., a report of preliminary trials made by a testing laboratory licensed under § 26-200 together with an attestation by the Architect or Engineer who supervised the making of the preliminary tests. The laboratory report shall include the following information:
         (i)   Fine and coarse aggregate.
            Type (natural or manufactured sand, gravel, stone, etc.).
            Weight per. cu. ft. dry rodded.
            Specific gravity.
            Percentage of voids.
            Percentage of absorption.
            Fineness modulus (see ASTM Definitions C 125).
            Gradation and comparison to ASTM C 33; also size of coarse aggregate.
         (ii)   Cement-type.
         (iii)   Batch weights.
         (iv)   Admixtures-type and amount.
         (v)   Test results of each particular mix design being submitted for approval. Separate tests shall be made for each compressive strength.
         (vi)   Attestation of the Architect or Engineer engaged by the producer or producers to supervise the tests.
         (vii)   Board of Standards and Appeals Cal. No. for items requiring Board approval, such as lightweight aggregate admixtures, etc.
         (viii)   Such other information required by §§ 27-605(a)(1), (2) and (3).
      (3)   Each concrete producer or group of producers that submits for approval the information required hereabove, shall be assigned an application number which is to be known as the "PREQUALIFIED MIX REFERENCE NUMBER." This REFERENCE NUMBER shall be valid only for the calendar year for which it is issued. All applications shall be submitted before November 1 of each year for review and for prequalification for the calendar year next following. When the concrete proposed for use is to be produced using the mix designs from a summary compilation that has been approved, the architect or engineer who has been retained to make or supervise the Controlled Inspection shall verify that the mixes have been approved as "PREQUALIFIED MIXES" and shall file a statement for each project setting forth the PREQUALIFIED MIX REFERENCE NUMBER from which the concrete mix proportions are to be selected.
   (c)   Mix designs previously approved and used.
      (1)   Each concrete producer making an application shall be assigned a PREQUALIFIED MIX REFERENCE NUMBER in the same manner as designated in 1 RCNY § 5-03(b)(3).
      (2)   The application shall set forth the details of location, date and laboratory that pertained to the previous project. It also shall include a statement setting forth the average strength obtained from tests made at the job, together with a summary of the total number of tests made and, of those tests, how many fell below the specified strength.
      (3)   A copy of the laboratory report that was originally accepted shall be submitted. It shall contain the information listed under 1 RCNY § 5-03(b)(2). (Reports with the water-cement ratios selected at a point on the curve established by preliminary mix tests corresponding to a strength of concrete 15% higher than the minimum ultimate strength called for on the plans shall not be accepted, unless the water-cement ratio complying with § 27-605(a)(2) can be determined.)
      (4)   The Architect or Engineer retained for the Controlled Inspection shall file a statement similar to the one mentioned in 1 RCNY § 5-03(b)(3).