§ 369.01 Requirements for Habitable Rooms
   Every dwelling unit shall conform to the following standards:
   (a)   Every dwelling unit shall contain at least one (1) room which shall have not less than one hundred twenty (120) square feet of habitable floor area. However, any room used for both living and cooking, or both living and sleeping, or for living, cooking and sleeping purposes shall have not less than one hundred fifty (150) square feet of habitable floor area.
   (b)   No portion of any room which is less than seven (7) feet in width shall be included in determining habitable floor area.
   (c)   All habitable rooms shall have a clear ceiling height of not less than six (6) feet, nine (9) inches, provided that rooms with sloping ceilings shall have a clear ceiling height of not less than six (6) feet, nine (9) inches in at least one-half (1/2) of their habitable floor area. In determining the habitable floor area of rooms with sloping ceilings, all portions of less than five (5) feet in height shall be disregarded.
(Ord. No. 2409-59. Passed 4-4-60, eff. 4-6-60)