Skip to code content (skip section selection)
Compare to:
Chicago Overview
Prior Chicago Building Code
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL CODE OF CHICAGO
DIVISION 1 - ADMINISTRATION
DIVISION 2 - DEFINITIONS
DIVISION 3 - USE AND OCCUPANCY CLASSIFICATIONS
DIVISION 4 - SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
DIVISION 5 - GENERAL BUILDING HEIGHTS AND AREAS
DIVISION 6 - TYPES OF CONSTRUCTION
DIVISION 7 - FIRE-RESISTANCE-RATED CONSTRUCTION
DIVISION 8 - INTERIOR FINISHES (NA)
DIVISION 9 - FIRE PROTECTION SYSTEMS
DIVISION 10 - MEANS OF EGRESS
DIVISION 11 - ACCESSIBILITY
DIVISION 12 - INTERIOR ENVIRONMENT
DIVISION 13 - ENERGY EFFICIENCY AND ENVIRONMENTAL PROTECTION
DIVISION 14 - EXTERIOR WALLS (NA)
DIVISION 15 - ROOF ASSEMBLIES AND ROOFTOP STRUCTURES (NA)
DIVISION 16 - STRUCTURAL DESIGN
DIVISION 17 - STRUCTURAL TESTS AND SPECIAL INSPECTIONS
DIVISION 18 - SOILS AND FOUNDATIONS
DIVISION 19 - CONCRETE
DIVISION 20 - ALUMINUM (NA)
DIVISION 21 - MASONRY
DIVISION 22 - STEEL
DIVISION 23 - WOOD
DIVISION 24 - GLASS AND GLAZING (NA)
DIVISION 25 - GYPSUM BOARD AND PLASTER (NA)
DIVISION 26 - PLASTIC (NA)
DIVISION 27 - ELECTRICAL
DIVISION 28 - MECHANICAL SYSTEMS
CHAPTER 18-28 MECHANICAL SYSTEMS*
Article I. Administration (18-28-101 et seq.)
Article II. Definitions (18-28-201 et seq.)
Article III. General Regulations (18-28-301 et seq.)
Article IV. Ventilation (18-28-401 et seq.)
Article V. Exhaust Systems (18-28-501 et seq.)
Article VI. Duct Systems (18-28-601 et seq.)
18-28-601 General.
18-28-601.1 Scope.
18-28-601.2 Deliberately omitted.
18-28-601.3 Contamination prevention.
18-28-602 Plenums.
18-28-602.1 General.
18-28-602.1.1 Technology centers.
18-28-602.2 Construction.
18-28-602.2.1 Materials exposed within plenums.
18-28-602.3 Stud cavity and joist space plenums.
18-28-602.4 Deliberately omitted.
18-28-603 Duct Construction and Installation.
18-28-603.1 General.
18-28-603.2 Duct classification.
18-28-603.3 Metallic ducts.
18-28-603.4 Deliberately omitted.
18-28-603.4.1 Gypsum ducts.
18-28-603.5 Deliberately omitted.
18-28-603.5.1 Flexible air ducts.
18-28-603.5.1.1 Duct length.
18-28-603.5.2 Flexible air connectors.
18-28-603.6 Deliberately omitted.
18-28-603.7 Underground ducts.
18-28-603.7.1 Slope.
18-28-603.7.2 Sealing.
18-28-603.8 Joints and connections.
18-28-603.9 Supports.
18-28-603.10 Furnace connections.
18-28-603.11 Condensation.
18-28-603.12 Locations.
18-28-603.13 Mechanical protection.
18-28-603.14 Weather protection.
18-28-603.15 Registers, grilles and diffusers.
18-28-603.15.1 Floor registers.
18-28-604 Insulation.
18-28-604.1 General.
18-28-604.2 Surface temperature.
18-28-604.3 Covering and linings.
18-28-604.4 Deliberately omitted.
18-28-604.5 Deliberately omitted.
18-28-604.6 Deliberately omitted.
18-28-604.7 Identification.
18-28-604.8 Lining installation.
18-28-604.9 Thermal continuity.
18-28-604.10 Service openings.
18-28-604.11 Vapor retarders.
18-28-604.12 Weatherproof barriers.
18-28-604.13 Internal insulation.
18-28-605 Deliberately omitted.
18-28-606 Smoke Detection Systems Control.
18-28-606.1 Control.
18-28-606.2 Where required.
18-28-606.2.1 Return air systems.
18-28-606.2.2 Common supply and return air systems.
18-28-606.2.3 Return air risers.
18-28-606.3 Installation.
18-28-606.4 Controls operation.
18-28-606.4.1 Connection to fire alarm system.
18-28-607 Ducts and Air Transfer Openings.
Article VII. Combustion Air (18-28-701 et seq.)
Article VIII. Chimneys and Vents (18-28-801 et seq.)
Article IX. Specific Appliances, Fireplaces and Solid Fuel-Burning Equipment (18-28-901 et seq.)
Article X. Boilers, Water Heaters and Pressure Vessels (18-28-1001 et seq.)
Article XI. Refrigeration (18-28-1101 et seq.)
Article XII. Hydronic Piping (18-28-1200 et seq.)
Article XIII. Fuel Oil Piping and Storage (18-28-1301 et seq.)
Article XIV. Fuel-Gas Piping (18-28-1401 et seq.)
Article XV. Solar Systems (18-28-1501 et seq.)
DIVISION 29 - PLUMBING SYSTEMS
DIVISION 30 - ELEVATORS AND CONVEYING SYSTEMS
DIVISION 31 - SPECIAL CONSTRUCTION (NA)
DIVISION 32 - ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
DIVISION 33 - SAFEGUARDS DURING CONSTRUCTION
DIVISION 34 - EXISTING STRUCTURES
DIVISION 35 - REFERENCED STANDARDS

You are viewing an archived code

Loading...
18-28-606.1  Control.
   Air distribution systems shall be equipped with smoke detectors listed and labeled for installation in air distribution systems, as required by this section.
18-28-606.2  Where required.
   Smoke detectors shall be installed where indicated in Sections 18-28-606.2.1 through 18-28-606.2.3.
   Exception: Smoke detectors shall not be required where air distribution systems are incapable of spreading smoke beyond the enclosing walls, floors and ceilings of the room or space in which the smoke is generated.
18-28-606.2.1  Return air systems.
   Smoke detectors shall be installed in return air systems with a design capacity greater than 2,000 cfm (0.9 m 3 /s), in the return air duct or plenum upstream of any filters, exhaust air connections, outdoor air connections, or decontamination equipment and appliances.
   Exception: Smoke detectors are not required in the return air system where the space served by the air distribution system is protected by a system of area smoke detectors in accordance with Chapter 15-16 of this Code. The area smoke detector system shall comply with Section 18-28-606.4.
(Amend Coun. J. 11-9-16, p. 36266, § 36)
18-28-606.2.2  Common supply and return air systems.
   Where multiple air-handling systems share common supply or return air ducts or plenums with a combined designed capacity greater than 2,000 cfm (0.9 m 3 /s), the return air system shall be provided with smoke detectors in accordance with Section 18-28-606.2.1.
   Exception: Individual smoke detectors shall not be required for each variable air volume (VAV) zone unit or VAV-type fan-powered terminal unit, provided that such units do not have an individual design capacity greater than 2,000 cfm (0.9 m3/s) and will be shut down by activation of one of the following:
      1.   Smoke detectors required by Sections 18-28-606.2.1 and 18-28-606.2.3.
      2.   An approved area smoke detector system located in the return air plenum serving such units.
      3.   An area smoke detector system as prescribed in the exception to Section 18-28-606.2.1.
   In all cases, the smoke detectors shall comply with Sections 18-28-606.4 and 18-28-606.4.1.
18-28-606.2.3  Return air risers.
   Where return air risers serve two or more stories and are part of a return air system having a design capacity greater than 15,000 cfm (7.1 m 3 /s), smoke detectors shall be installed at each story. Such smoke detectors shall be located upstream of the connection between the return air riser and any air ducts or plenums.