Loading...
DESIGN STANDARDS
(A) In order to insure that new development, renovations, and reconstructions are designed, sized, and sited to complement the area in which they are located and the character of the city in general; and to minimize traffic hazards and situations which endanger public safety; and to protect existing development and property values through the promotion of high standards of design and compatibility; and to provide for a high quality of life for our citizens by promoting a variety of housing styles, transportation choices, and well planned parks and open spaces; the following standards shall apply to all development in all zoning districts unless otherwise noted.
(B) The following design standards shall apply to a specific type of land use or an overlay district insomuch as the standard would apply to the applicable underlying district, unless properties in an overlay are otherwise exempted within the text of this Zoning Ordinance. Please review the overlay district requirements as set out in § 157.030 for guidance on interpreting applicability of these standards to an individual property or district. The category "All Commercial" shall apply to all commercial development, including businesses, offices, and industrial uses unless otherwise noted.
(Ord. 15-002, passed 2-24-15)
(A) Applicability. The following standards shall apply to all new single-family detached dwellings in the city, except for the following:
(1) Single-family detached dwellings that are more than 100 feet from the street and cannot be seen from the street.
(2) All new single-family detached dwellings in existing neighborhoods approved prior to June 30, 2024 must show general compatibility with homes in the neighborhood by using the same or similar design elements, features and construction style. Enough of the following elements must be compatible with homes in the existing neighborhood so that the new dwelling does not stand out as being out of place within the context of its surroundings.
(a) Foundations.
(b) Roof slopes.
(c) Front and side façade materials.
(d) Window and doors.
(e) Front porches (whether they exist or not).
(f) Garage/carport (whether they exist or not, and location and design).
(g) Location and visibility of parking area and access drive.
(h) Size of structure (overall mass compared to other residences in the area as well as amount of the lot taken up by the residence).
(i) Height of structure (no more than one story taller than adjacent structures).
(j) Width and length of residence.
(k) Setbacks and building placement on parcel.
(3) Properties regulated by the Historic Landmarks Commission will follow the Camden Design Guidelines instead of these standards.
(B) The following shall apply to all building plans within new subdivisions submitted on or after June 30, 2024.
(1) Allowed materials. The following exterior materials are allowed on any building façade. Each façade must use the same primary material.
(a) Brick or brick veneer (veneer must be made of brick).
(b) Stone or stone veneer (veneer must be made of stone).
(c) Stucco or synthetic stucco except within two feet of the grade level or within two feet of any exterior door jamb.
(d) Wood.
(e) Cementitious siding (i.e. Hardiplank).
(f) Vinyl siding, provided that panels are at least 0.42 millimeters thick, and are at least 12 feet long except in areas that are shorter than that (such as end of a row).
(2) Prohibited materials. The following materials are prohibited on all façades:
(a) Metal siding.
(b) Exposed smooth-finished concrete block.
(3) Architectural design. New residential construction within the City of Camden shall reflect the historic vernacular of the existing neighborhoods. Contemporary interpretations of traditional and classical architectural styles are encouraged with respect to scale, style and use of materials.
(4) Façade variation required. For all developments involving more than four contiguous lots, any given house must be distinctly different from those of the two lots on either side and the house most directly across the street. "DISTINCTLY DIFFERENT" means that a single-family detached dwelling's elevation differs from the other evaluated house elevations in at least three of the following ways:
(a) The use of different surface materials.
(b) Variations in rooflines, pitches or the use of dormers.
(c) Variation in the location and/or proportions of front porches.
(d) Variation in the location and/or proportion of garages or carports and garage doors.
(5) Homes with brick on all sides are required to meet only two of the criteria in divisions (4)(a) - (d) above.
(6) At least 50% of the new dwellings on all blocks must include a front porch with a minimum depth of five feet and a minimum width of eight feet.
(7) Windows. Any window installed must be designed so the width does not exceed the height.
(8) Front façades.
(a) All single-family detached dwellings must have an offset every 25 feet.
(b) A front porch with a minimum depth of five feet and a minimum width of eight feet may be used as an alternative.
(c) No more than two different types of materials shall be used on the façade, excluding foundation material.
(9) Side façades. The following standards apply except when the house qualifies as an infill dwelling according to § 157.094
(A)(2), or when the side has a side-loaded garage.
(a) Where the side of a dwelling faces another dwelling, the façade must include at least one window of standard size (i.e. 48 inches by 20 inches) or larger every 20 feet of façade length per story with applied trim that is at least 3.5 inches.
(b) Where a side of a dwelling will be visible due to facing a road (as with a corner lot), common space, or a neighborhood amenity space, the façade must include at least one window of standard size (i.e. 48 inches by 20 inches) or larger every 20 feet of façade length per story with applied trim that is at least 3.5 inches, and one of the following:
1. Wrap-around porch that is at least 48 square feet on the side façade; and/or
2. Substantial façade line changes, such as through varying number of stories, dormers, architectural additions, bay windows, roof styles and chimneys.
Examples of the intent of this standard are shown below:

(c) Other methods of achieving architectural variability that meets the intent of this section where unique circumstances exist may be approved by the Planning and Development Director.
(10) Garages and carports.
(a) Garages and carports may be attached or detached. Detached garages or carports shall also comply with requirements in § 157.060.
(b) Design standards for front-loaded garages and carports.
1. Exterior materials, design features and roof form of garages must be consistent with the building they serve. Metal is an allowed material for detached carports, provided that they are screened from view of adjacent roads.
2. Front-loaded attached garages and carport features must be set back at least one-third the depth of the side façade behind the front plane of the primary portion of the structure.
3. House designs with the front entryway recessed between the attached garage and a conditioned room are not allowed, even if the conditioned room is located two feet in front of the plane of the garage. This shall not prevent a breezeway connecting a dwelling and detached garage.

(c) Front-loaded attached garages must not exceed 16 feet in width per garage door unless the garage is set back at least half the distance of the length of the dwelling from the front façade of the structure, or in limited cases, to make an accommodation for wheelchair van access or similar special needs. In no case shall the width of a garage exceed 50% of the width of the front façade.
(d) Front-loaded attached garages must have at least two of the following architectural features on the side: trellis, columns, portico treatment, windows, dormers, overhangs, eaves, or roof line changes, and be consistent with the architecture of the dwelling.
(e) A maximum of two garage doors may front the street and be visible from the street for each dwelling, and a minimum separation of at least one foot must be provided between the doors.
(11) Design standards for side-loaded garages and carports.
(a) The exterior materials, design features and roof form of garages must be consistent with the building they serve. Metal is an allowed material for detached carports if they are screened from view of adjacent roads.
(b) Attached side-loaded garages must have architectural features and windows that complement the features of the living portion of the dwelling on the front façade. The width of the conditioned spaces that face the street must be no more than one-third the width of the front façade.
(c) A maximum of two garage doors may face the street and be visible from the street for each dwelling, and a minimum separation of at least one foot must be provided between the doors.
(d) The design of the garage doors must complement the design of the dwelling. The garage doors must contain at least two of the following architectural features: decorative patterning (other than standard rectangular boxes), windows, a rounded shape, or faux wood appearance, and be consistent with the architecture of the dwelling.
(12) Building foundations. Homes must use one of the following:
(a) A crawl space with a minimum height of 18 inches that is clad with brick, brick veneer, stone, stone veneer, stucco, or other masonry materials on the front and side façades.
(b) A slab foundation, provided that the foundation supporting the floor framing is an average of at least 18 inches above grade on the front and side façades and is clad with brick, brick veneer, stone, stone veneer, stucco, or other masonry materials on the front and side façades.
(c) Alternatively, a basement foundation may be used on the sides and/or rear façades.
(d) Slab on grade foundations provided that an average of 18 inches from the ground level is clad with brick, brick veneer, stone, stone veneer, stucco, or other masonry materials on the front and side façades. This shall not apply to houses with brick, stone or stucco siding.

(e) Foundations shall not be clad in finished or unfinished concrete block.

(13) Eaves. Eaves must extend beyond the plane of façade by at least six inches. Similar treatments such as coping on top of a brick façade or a stucco parapet wall are also allowed.
(14) Entries. All entries must be sheltered with an overhang, portico, or porch.
(15) Roof penetrations. All roof vents, pipes, antennas, satellite dishes, solar installations, and other rood penetrations and equipment (except chimneys) must be configured to the degree practicable to have a minimal visual impact as seen from the street.
(16) Roof materials. 3-tab shingles are not allowed. Architectural shingles and metal roofs are allowed. Metal roofs shall have a matte, non-reflective surface.
(Ord. 15-002, passed 2-24-15; Am. Ord. 2024-014, passed 6-25-24)
(A) Applicability. The following standards shall apply to all new single-family attached dwellings in the city. For projects built under old standards but that have space for additional buildings, all new buildings are expected to meet these standards unless it is determined:
(1) The location is not on an arterials and collector road or other highly visible location where strict compliance is crucial to meeting overall city aesthetic goals; and
(2) The likelihood is low of surrounding non-conforming buildings changing use, being redeveloped, or otherwise being brought into greater compliance with these design standards within the foreseeable future.
(B) New construction. The following standards apply to all building plans approved after June 30, 2024.
(1) Building orientation.
(a) Buildings must be oriented so that the primary entrances of the units face either a public street, whether internal or external to the development, or a central courtyard area with at least one side of the courtyard containing no units.
(b) When buildings face a public street, whether internal or external to the development, no buffer is required between the units and the road. When the sides or rear of buildings face a public street, a buffer shall be required according to the buffer requirements of the Zoning Ordinance.
(c) Buildings must be oriented so that the fronts of units do not face the sides or rears of other buildings.
(2) Allowed materials. The following materials are allowed on any façade:
(a) Brick or brick veneer (veneer must be made of brick);
(b) Stone or stone veneer (veneer must be made of stone);
(c) Stucco;
(d) Wood;
(e) Vinyl siding, provided that panels are at least 0.42 millimeters thick, are at least 12 feet long except in areas that are shorter than that (such as end of a row); and
(f) Cementitious siding (i.e. Hardiplank).
(3) Prohibited materials. The following materials are prohibited on all façades:
(a) Metal siding (unless architectural grade in limited application such as design accent or feature only);
(b) Exposed smooth-finished concrete block; and
(c) Plywood.
(4) Windows. Any window installed must be designed so the width does not exceed the height.
(5) Front façade.
(a) No more than two different types of materials shall be used on a façade, excluding the foundation material.
(b) For duplexes, the same exterior material must be used on each unit.

(c) Façade uniformity. Units are not required to be symmetrical, but it is allowed.

(6) Architectural variability.
(a) Rooflines. Each building must have roofline differentiation of at least 16 inches either vertically or horizontally between each unit, or gables or dormers on each unit.
(b) Each building with three or more units must have at least three of the following on the front façade of the building (upstairs or downstairs) on one or more of the units:
1. A porch;
2. A bay window;
3. A gable;
4. A dormer; and
5. A shed roof.
(7) Side façades. The side façades of single-family attached homes must be the standards of § 157.094
(B)(9).
(8) Garages and carports.
(a) The exterior materials, design features and roof form of garages and carports must be compatible with the building it serves.
(b) Garage doors facing a public street or public open space must be recessed within the façade and include detailing elements to create visual interest and add to the overall character of the building. This does not apply to garage doors facing an alley, service area, or otherwise nonpublic area.
(9) Building foundations. One of the following is required on all homes except for dwellings designed or intended for occupation by persons with physical disabilities:
(a) An 18-inch crawlspace that is clad with brick, brick veneer, stone, stone veneer, stucco, or other masonry materials on the front and side façades; or
(b) A slab foundation, provided that the foundation supporting the floor framing is an average of at least 18 inches above grade on the front and side façades and is clad with brick, brick veneer, stone, stone veneer, stucco, or other masonry materials on the front and side façades.
(c) A slab-on-grade foundation, provided that an average of 18 inches from the ground levels is clad with brick, brick veneer, stone, stone veneer, stucco, or other masonry materials on the front and side façades. This shall not apply to dwellings with brick, stone or stucco siding.
(d) Alternatively, a basement foundation may be used on the sides and/or rear façades.
(e) Foundations shall not be clad in finished or unfinished concrete block.
(10) Eaves. Eaves must extend beyond the plane of façade by at least six inches. Similar treatments such as coping on top of a brick façade or a stucco parapet wall are also allowed.
(11) Entries. All entries must be sheltered with an overhang, portico, or porch.
(12) Outdoor area. In addition to the common open space required for the entire project, each unit must have an outdoor living area for the residents to use for recreation. Specific standards include:
(a) Types. The outdoor area may take forms such as, but not limited to, a yard, balcony, covered or screened porch, rooftop area, patio or deck.
(b) Location. The private outdoor area must be fully contained on the individual parcel, outside of all required utility easements.
(c) Size. The private outdoor living area must be at least 200 square feet in area per unit. This area may be physically broken up into two separate areas, but neither area may be smaller than 48 square feet.
(d) Separation. Private outdoor living areas must have physical separation from adjacent units through building walls, fences, hedges, or similar. The physical separation is not required to provide a full screen; for example, a three-foot hedge or decorative fence is allowed.
(e) Surfacing. Private outdoor areas must have a surface appropriate for the use.
(f) Parking areas. Parking areas that are provided to meet the parking standards of this section and driveways that access a garage do not count as approved outdoor areas.
(Ord. 2024-014, passed 6-25-24)
(A) Applicability. The following standards apply to all building plans approved after June 30, 2024. For projects built under old standards but that have space for additional buildings, those new buildings would be expected to meet these standards unless it is determined:
(1) The location is not on an arterials and collector road or other highly visible location where strict compliance is crucial to meeting overall city aesthetic goals; and
(2) The likelihood is low of surrounding non-conforming buildings changing use, being redeveloped, or otherwise being brought into greater compliance with these design standards within the foreseeable future.
(B) Design intent. The following design standards are intended to create high quality, walkable urban environments based on time-tested urban design principles. These principles, along with the careful location of these buildings and communities in high-amenity, mixed-use locations, are intended to create long-term value that allows buildings to become even more coveted addresses over time. Architectural details, the design quality and functionality of open spaces, and the design and functional integration of these buildings and communities with their surrounding mixed-use environment are the important public interests that are reflected in these standards.
(C) Orientation of buildings to streets and open space.
(1) All multi-family dwellings must be oriented so that the primary entrance(s) and street-level unit entries face the street. In the case of corner lots, the primary entrance(s) must face the street from which the building derives its street address. It is acceptable to have two primary entrances, but no secondary entrance may face a street. A primary entrance is defined by the entrance's function, scale, and/or design detail.
(2) When a required open space area is included within the development, at least 10% of the dwelling units must front the open space area; this includes lots where a street is located between dwelling units and the open space. The percentage may be reduced if the open space is designed to preserve specific natural features, or extend existing open space or pedestrian corridors, or such a percentage cannot be reasonable met.
(3) Within the context of other design requirements, streets and buildings should be arranged to frame the open space to the maximum extent practicable (see picture below).

(D) Open space. Required open space must be functional and enhance the resident or visitor's experience. Amenities include special paving, enhanced landscaping, trellises, and other features that promote outdoor recreation, scenic amenity, and/or shared exterior space for people to gather. See examples below.

(E) Parking. Multi-family projects must comply with the following, in additional to any related standards elsewhere in this subchapter.
(1) Off-street parking lots associated with multi-family dwellings cannot be located between any structures and the street.
(2) Off-street parking lots located next to a building must not occupy more than 25% of the parcel's street frontage. Associated driving areas must be included as part of such off-street surface parking.
(3) Any podium parking or structured parking should be adequately screened and integrated into the overall design of the building through the use of metal screens, louvers, grilles, and/or green screens.
(F) Pedestrian walkways.
(1) Continuous internal pedestrian walkways must be provided to connect off-street parking areas with primary building entrances and the public sidewalk system.
(2) If a public sidewalk is adjacent to the project site, at lease one internal pedestrian walkway with a minimum width of five feet must be provided from the primary entrance to the public sidewalk at a major connection point. In the case of a corner lot, a connection must be made to the sidewalk of both streets.
(3) The crossings at major entrances, major internal routes, and major pedestrian walkways must be distinguished from driving surfaces through the use of durable, low-maintenance surface materials such as pavers, bricks, or scored/stamped concrete or asphalt to enhance pedestrian safety and comfort, as well as the attractiveness of the walkways.
(G) Building size. Individual building footprints are limited to 15,000 square feet, or in cases where at least 25% of the ground floor is reserved for neighborhood commercial uses served by their own exterior entrance, to 25,000 square feet. A larger building footprint may be approved by the Planning Commission for special purpose facilities or an established mixed-use area if compatible with the sale of the surrounding development.
(H) Building massing.
(1) All building façades of multi-family uses must include a distinguishable and distinct base, middle and top such that the base of the building relates to the pedestrian scale.
( 2) All buildin g elevatio ns must be treated in a consiste nt manner regardi ng the design, material s, color, and complex ity, unless the elevatio n exclusiv ely fronts a service area or alley, or is otherwise not visible from to the general public.

Base, middle and top examples
(I) Design of front façades.
(1) Façades must incorporate wall offsets in the form of projections and/or recesses in the façade plane at least every 30 feet of façade frontage.
(2) Wall offsets, resets, and projections must have a minimum depth of two feet.
(3) The building façade must express the module of the actual residential unit in order to scale to create a façade that has depth, visual interest, and rhythm.
(4) In additional to wall offsets, façades of multi-family buildings must provide a minimum of four of the following design features in a cohesive manner for each residential unit fronting onto a public street or public space unless there are unique and challenging circumstances that would otherwise make the implementation of these features not feasible (such as incompatibility with an established building aesthetic, lack of public visibility, or demonstrated physical constraints of the site):
(a) One or more dormer windows or cupolas above the corresponding residential unit.
(b) A projecting or recessed balcony for at least 50% of the units facing a public street or public space and a covered porch for each unit at ground-level facing a public street or public space.
(c) Ornamental pilasters, columns, or other similar architectural features integrated into the overall architectural design.
(d) One or more bay windows with a minimum 12-inch projection from the façade plane.
(e) Eaves with a minimum of six-inch projection from the façade plane.
(f) A parapet wall with an articulated design, which entails design variation rather than a simple rectilinear form.
(g) Multiple windows grouped together to establish a design feature that can be either recessed or projecting with a minimum four-inch wide trim.
(h) Windows that have dimensional window surrounds or trim.
(i) Windows that incorporate ornamental elements such as shutters, arched windows, transom windows, or any other design feature that would otherwise add ornamental characteristics to a window or group of windows.
(j) Other prominent design details that are consistent with the overall architectural character and scale of the building.
(5) Pitched roofs must have multiple planes and elements, including hips, gables and dormers reflecting required wall offsets or other architectural features of the building, with at least one additional roof plane or feature for every 60 feet of façade frontage.
(6) Flat roofs should include elements that act as a prominent visual termination for the building, such as projecting architectural features, cornices, and eaves. Where a flat roof is used, a parapet should extend beyond the roof plane and include an element that provides a visual termination of the façade. The parapet should extend far enough above the roof plane that any mechanical equipment is concealed from public view at street level.
(J) Consistency of façade design. Each façade must receive similar treatment to the façades that are oriented toward the street. They should have variation in massing, similar pattern of openings, at least one projection or recess, or one bay window or covered porch meeting the standards in division (I) above. This requirement may be waived by the Planning Commission for adjacent building sides or façades otherwise oriented with minimal public visibility.
(K) Design of building entries.
(1) At any entry, whether a common entry or access to an individual unit entry at ground level, a canopy, awning, balcony, or other significant architectural feature combined with the entry itself being either recessed or projecting from the primary façade must be provided to promote pedestrian safety and orientation to the building by creating a well-defined and welcoming building entry.
(2) Shared or common building entries should provide a transition from the street to the entries themselves to create a unique shared sense of entry that provides a defensible space, therefore generating a sense of pride and ownership. This can be accomplished by changes in grade, stairs, low masonry walls, ornamental railing, a change in paving materials and/ or landscaping.
(3) Exterior, open corridors (breezeways) designed to provide primary, street-side access to dwellings are prohibited, whether the breezeways are ground level or elevated.
(4) All residential units, other than units that are accessed individually directly from the exterior, should be accessed through enclosed, shared common access points that are monitored by a security system and/or on-site security/management staff and be accessible to emergency responders. Building access must be provided via a keypad entry, card access, or similar system equipped with the ability to provide on-demand access to emergency responders.
(L) Building foundations.
(1) A slab foundation is permitted, provided that the foundation supporting the floor framing is an average of at least 18 inches above grade on the front and side façades and is clad with brick, brick veneer, stone, stone veneer, stucco, or other masonry materials on the front and side façades.
(2) Buildings that are age-restricted to citizens ages 55 and older, and buildings that are designed or intended for occupation by persons with physical disabilities may use a slab-on-grade foundation or raised slab foundation, provided that an average of 18 inches from the ground levels is clad with brick, brick veneer, stone, stone veneer, stucco, or other masonry materials on the front and side façades.
(3) Foundations shall not be clad in finished or unfinished concrete block.
(M) Building materials.
(1) Buildings must have a minimum of 50% brick, stone or stucco on façades facing a public street or public open space, and 30% brick, stone or stucco on façades that front service areas or alleys, or are otherwise not visible to the general public. Stucco or synthetic stucco (EIFS) may only be placed above the first building level on all façades, except for detailed design elements that may extend to the ground level.
(2) The following materials are prohibited for all building elevations:
(a) Metal siding (unless architectural grade in limited application such as design accent or feature only).
(b) Vinyl siding.
(c) Plywood.
(d) Exposed smooth-finished concrete block.
(3) Changes in materials and color should correspond to the building modulation and other architectural features of the building. At a recess, projection or change in material, the materials should return to meet the primary façade.

(N) Windows, doors, balconies, patios and porches.
(1) Windows and doors should be recessed within the façade in which they are located or have dimensional surrounds/trim a minimum of four inches wide.
(2) False balconies (or Juliet balconies) should not be used unless the depth is at least 12 inches from the façade.
(O) Garages and carports.
(1) Garages/carports serving multi-family buildings must be located to the side or rear of the building.
(2) Garage doors are prohibited from facing a public street.
(3) Side-facing garages must not face existing single-family detached dwellings unless a perimeter buffer with a minimum width of 30 feet is provided between the garage and existing single-family detached dwellings.
(4) The exterior materials, design features, and roof form of garages and carports must be compatible with the building they serve.
(5) Garage doors facing a public street or public open space must be recessed within the façade and include detailing elements to create visual interest and add to the overall architectural character of the building. This does not apply to garage doors facing an alley, service area, or otherwise non-public area.
(P) Roof penetrations and equipment.
(1) To the degree practicable, all roof vents, pipes, antennas, satellite dishes, and other roof penetrations and equipment (except chimneys) must be located on the rear elevations or configured to have a minimal visual impact as seen from the street.
(2) Where wall-mounted equipment is visible from the street or any public area, it should be of similar color to the façade on which it is located and be integrated into the overall design.
(Q) Unique conditions and exceptions. In situations where the applicant can show that building orientation, building layout, adjacent land use, or other determining factors preclude adherence to the standards, the Planning and Development Director may reduce the applicable standards of this section after all reasonable efforts are made to incorporate them in their entirety.
(Ord. 2024-014, passed 6-25-24)
(A) Applicability.
(1) These non-residential design standards apply to all new public, institutional, commercial and industrial development.
(2) In addition to new non-residential development, these standards also apply to any existing non-residential buildings if any expansion or alteration exceeds 50% of the structures gross square footage at the time of expansion or alteration.
(3) The approving authority for a site plan, subdivision plat, or other permit may modify or waive any or all of these standards for industrial uses when they conflict with the covenants or design scheme of an existing industrial park. Modification or waiver must consider the following criteria:
(a) The surrounding area is substantially developed with buildings not meeting any or all of these standards;
(b) The location is not on an arterial or collector road or other highly visible location where strict compliance is crucial to meeting overall city aesthetic goals; and
(c) The likelihood of surrounding non-conforming buildings changing use, being redeveloped, or otherwise being brought into greater conformance with these design standard within the foreseeable future is low.
(B) Building presentation and wall pattern. Front building façades shall be substantially parallel to the front property line except that:
(1) The entrance of corner buildings may be oriented to front the corner;
(2) Buildings interior to a development site may be arranged to front a common courtyard, parking area, driveway;
(3) Where the street curves at the front property line the building shall be parallel to a tangent of the curve that does, or would if lines were extended, intersect the side property lines;
(4) In pedestrian-oriented areas such as the Central Business District, an operable primary building entrance must face the street;
(5) In automobile-oriented transportation corridors, the operable primary entrance is considered the main customer entrance and may face a street or parking lot;
(6) Side yard houses built to conform to historic design principles shall be exempt from this requirement.
(C) Building articulation required. In order to provide building articulation and interest in design and human scale to the façade of a building, a variety of building techniques are required. The purpose of this section is to ensure that the front of non-residential structures have a variety of offsets, relief, and insets to provide a more interesting façade appearance. Front façades more than 60 feet wide must comply with the following articulation requirements.
(l) Horizontal articulation.
(a) A wall must have a perpendicular offset after a horizontal span of two times its average height, or more frequently if desired.
(b) The offset depth must be at least 5% of the average building height. Offsets can be of varying depth as long as this minimal standard is met.
(c) The offset must extend laterally for a distance equal to at least 10% of the entire façade, up to a maximum of 40 feet.
(d) Industrial buildings may use a change of materials, colors, or texture to meet the horizontal articulation requirements. Buildings must still meet the distance and length requirements above.
(e) For calculation purposes, the façade will be considered the total distance of the building façade.

(2) Vertical articulation.
(a) A wall must chance elevation after a horizontal span of two times its average height, or more frequently if desired.
(b) The change in height must be at least 15% of the average building height.
(c) The elevation chance must continue to extend laterally for a distance equal to at least l0% of the entire façade, up to a maximum of 40 feet.
(d) Elevation changes can be of varying heights as long as the minimal standard is met.
(e) For calculation purposes, the façade will be considered the total distance of the building façade.

(3) Prominent entry. All non-residential buildings must have at least one prominent entry. All non-residential buildings other than industrial uses must use at least two of the following features, and industrial uses must use at least one feature:
(a) Canopies, porticos, or roof overhangs above the entrance;
(b) Entry recesses/projections, with raised parapets, gabled roof forms, arcades, or arches above the entrance;
(c) Architectural details, such as tile work and moldings, that are integrated into the building structure and design, and are above and/or directly adjacent to the entrance; or
(d) Integral planters or wind walls that incorporate landscaped areas or seating areas. A wing wall is a wall secondary in scale projecting from a primary wall and not having a roof.
(D) Building materials.
(1) Prohibited materials.
(a) Lap siding is only permitted on office and commercial buildings of less than 10,000 square feet, and above the ground floor of multi-story mixed-use buildings. Vinyl lap siding must have a smooth finish with no visible grain pattern.
(b) Stucco or synthetic stucco is prohibited on buildings larger than 10,000 square feet, and within two feet of the grade level or within two feet of any exterior door jamb.
(2) Colors.
(a) Paint colors used on exterior walls of non-residential buildings shall be of low reflectance, subtle, neutral, or earth-tone colors or shall relate to historic building colors found within the city generally or on neighboring historic buildings. Contrasting colors shall be kept in tone with the primary color.
(b) The exterior wall area of each side of the building may contain nonfluorescent highlighting trim or dark contrasting features which use bright, dark, or vivid colors, but are restricted to no more than 10% of the façade.
(E) Roofs.
(1) Roof planes. Except for mansard roofs, cupolas, and steeples, sloped roofs must include two or more sloping roof planes with greater than or equal to one foot of vertical rise for every three feet of horizontal run, and less than or equal to one foot of vertical rise for every one foot of horizontal run.
(2) Flat roofs. When flat roofs are used, parapet walls with three-dimensional cornice treatments must conceal them. The cornice must include a perpendicular projection a minimum of four inches from the parapet façade plane.
(3) Pitched roofs. Pitched roofs shall be dark-colored fiberglass shingles (except red and blue), slate, clay tile, or standing-seam metal roofs.
(4) Allowable roof colors.
(a) Asphalt shingles may be any color except red or blue.
(b) Metal, plastic or fiberglass roofs may be tan, gray, brown, slate, clay, black, white, burgundy, evergreen or metallic.
(5) Services and utilities.
(a) All loading docks, storage areas, solid waste, maintenance equipment and similar items shall be screened from public view.
(b) Mechanical equipment at ground level shall be placed on the parking lot side of buildings away from public streets and buildings on adjacent sites, except for single-family residential uses and industrial buildings in the CMU zoning district. All such equipment shall be substantially screened from public view.
(c) Mechanical equipment and antennas located on rooftops shall be camouflaged as a normal architectural feature of the building, or hidden by a decorative cornice or parapet wall, as seen from the ground.
(d) All trash and recycling receptacles and storage areas shall be located away from public streets and screened entirely from public view.
(e) All non-vegetative screening used to block public view of trash and recycling receptacles and storage areas shall be made of materials compatible in color and type to the principal structure(s) on the property.
(f) Drive-thru windows, freestanding ATMs, and similar devices and accessory uses shall only be placed in areas that will not interfere with the safe movement of pedestrians and vehicles in parking and driveway areas.
(g) Drive-thru windows, freestanding ATMs, and similar devices shall not be placed between the primary façade of a building and the public street.
(Ord. 2024-014, passed 6-25-24)
(A) Materials. These standards are in addition to the non-residential design standards for all non-residential buildings.
(1) Exposed smooth-finished concrete block, sheet metal and corrugated metal are prohibited as an exterior wall material on all buildings except for the rear side of commercial and industrial buildings that area screened from public view.
(2) Buildings not intended for industrial use must use brick, brick veneer, stone, or stone veneer as a primary material on all façades, not only limited amounts on key architectural features.


(3) When a more modem architectural design is used, glass, wood, brick, brick veneer, stone, or stone veneer may be used as primary building materials. The use of EIFS in modern is allowed but should be minimized.

(4) Lap siding of any material is not allowed on any building façade that is visible from any street.
(5) Corrugated metal roofs and metal panel roofs with exposed edges are not allowed. This standard applies to all non-residen tial uses including industrial uses.

(B) 360-degree design.
(1) Archit ectural and signage towers that are out of scale in terms of size or height with the overall structure are not allowed.

(2) Conversely, architectural and signage towers may be used as accent features extending above the primary roofline provide d that they are in scale in terms of size and height with the overall structure. Signage may be placed higher than the roofline when these elements are used. However, the colors used on the tower must be muted.

(C) Iconic or unusual shapes. Unique architectural features, regardless of whether or not they are associated with a specific brand, are not allowed.

(D) Colors.
(1) Paint colors used on exterior walls of non-residential buildings shall be of low reflectance, subtle, neutral, or earth tone colors or shall relate to historic building colors found within the city generally or on neighboring historic buildings. Contrasting colors shall be in tone with the primary color.
(2) The exterior wall area of each side of the building may cont ain nonf luorescent high lighting trim or dark contrasting features that use bright, dark, or vivid colors, but are restricted to no more than 10% of the façade.

(E) Mechanical equipment. Mechanical equipment and antennas located on rooftops shall be camouflaged as a normal architectural feature of the building, or hidden by a decorative cornice or parapet wall, as seen from the ground.
(Ord. 2024-014, passed 6-25-24)
(A) Materials. Buildings not intended for industrial use must use brick, brick veneer, stucco, stone, stone veneer, or fiber cement siding (e.g. HardiePlank) as a primary material on all façades, not only limited amounts on key architectural features.
(B) Building design.
(1) The scale and design of the exterior of any new building or the renovation of the exterior of any existing building fronting the following street segments shall be of a design that is architecturally compatible and in aesthetic harmony with nearby historic properties. Brick veneers must be of a compatible color and style.
(2) Doors and windows that operate as sliders are prohibited.
(3) Openings above the first story shall not exceed 50% of the exterior wall area, with each floor calculated independently. However, individual windows shall be a minimum of 15 square feet.
(4) All openings, including porches, and windows, with the exception of shopfronts, shall have a width that does not exceed height.
(5) Awnings.
(a) Awnings, where provided, shall be placed at the top of window and door openings and shall relate to the shape of the top of the window or doorway.
(b) Awnings shall be made of canvas, vinyl or similar material.
(c) Awnings shall be self-supporting from the wall; no supports shall rest on or interfere with the use of pedestrian walkways, streets, trees or utilities. Awnings shall extend over a light gauge frame.
(d) Awnings may encroach the sidewalk up to four feet, must clear the sidewalk vertically by at least eight feet but by no more than 12 feet, and shall not be placed closer than six feet to a the trunk of a tree.
(e) Lights may be installed underneath awnings only if they are directed to point toward the ground, and are not used to illuminate the awning.
(C) Shopfront façade required.
(1) Buildings with frontage on the following street segments shall meet additional design standards:
(a) Broad Street: Dekalb Street to York Street.
(b) Dekalb Street: Church Street to Little Street.
(c) Rutledge Street: Church Street to Lyttleton Street.
(d) Clyburn Lane: Broad Street to Market Street.
(e) Market Street: Dekalb Street to York Street.
(2) With the exception of civic buildings, all buildings shall have the first floor designed with a shopfront at sidewalk level along the entire length of the building front.
(3) Shopfronts (first floor only) shall contain no less than 50% glazing with clear glass. Glass shall be a minimum of 18 inches above the sidewalk.
(4) New construction and additions to or remodeling of existing buildings shall maintain a clear visual division between street level and any upper floors using cornice lines, windows, or similar architectural elements.

(5) Signs. Lettering and logos on a freestanding and wall signs can only be internally illuminated using silhouette lighting.
(Ord. 2024-014, passed 6-25-24)
SIGN REGULATIONS
The purpose and intent of these regulations is to protect the dual interests of the public and the advertiser. The regulations herein are designed to protect public safety and ensure the maintenance of an attractive physical environment, while satisfying the needs of sign users for adequate identification, communication and advertising.
(Ord. 15-002, passed 2-24-15)
(A) A sign may be erected, placed, established, created, installed or maintained in the city only in conformance with the requirements of this subchapter. From and after its adoption, no sign may be enlarged, erected, modified or replaced unless it conforms to the requirements of this subchapter.
(B) All signs located in a Historic Overlay District shall be subject to additional requirements as provided in Chapter 158.
(Ord. 15-002, passed 2-24-15)
(A) Location.
(1) No sign shall be located within the visual clearance areas as defined in § 157.191.
(2) Signs shall relate in their placement and size to other building elements without obscuring building elements such as windows, cornices, or decorative details, except that signs may be placed on the inside of windows where permitted by and according to such standards set forth in this Zoning Ordinance.
(B) Pedestrian area clearance. When a sign extends over a sidewalk, walkway or other spaces accessible to pedestrians, the bottom of the sign structure shall be at least eight feet above the ground.
(C) Vehicle area clearance. When a sign extends over an area where a vehicle travels or is parked, the bottom of the sign shall be at least 14 feet above the ground. Vehicle areas include driveways, alleys, parking lots, and loading and maneuvering areas.
(D) Construction. All signs must:
(1) Be constructed in compliance with all applicable provisions of the Building Code and the Electrical Code;
(2) Consist of durable all-weather materials;
(3) Be maintained in good condition; and
(4) Not be permitted to fall into disrepair.
(E) Signs shall not have light-reflecting backgrounds, but may use light-reflecting lettering.
(F) Illumination.
(1) Light sources used to externally illuminate signs shall only use white lights, must be shielded and shall be directed so that all direct light falls entirely on the sign face.
(2) Light sources used to illuminate signs shall neither be visible from any street right-of-way nor cause a glare hazardous to pedestrians or vehicle drivers, and shall not create a nuisance to adjacent properties.
(3) No illumination simulating traffic control devices or emergency vehicles shall be used; nor shall lights that are intermittently switched on and off, changed in intensity or color, or otherwise displayed to create the illusion of flashing or movement be permitted.
(4) Illumination using exposed bulbs is prohibited.
(5) Lights used to illuminate signs must remain at a constant intensity.
(6) Neon lights or strip lights are not allowed on the exterior of a building unless they are used as an internal light source of translucent panels or signs.
(7) Signs for permitted nonresidential uses in residential zoning districts may be internally or externally illuminated.
(8) In the Corridor Overlay District and Downtown Core lettering and logos on a sign can only be internally illuminated using silhouette lighting.
(G) Colors.
(1) No fluorescent colors shall be used.
(2) The only colors allowed for the background of signs are white, grey or any pastel color except as follows:
(a) In CBD, GBD, IND, and CMU zoning districts, the background of freestanding signs, except incidental signs, that do not exceed 40 square feet in area and six feet in height shall be any non-fluorescent color.
(b) The background of flush-mounted building signs may be black, blue or green; if the background color is used as a highlighting color on the exterior wall areas.
(H) Sign measurement.
(1) The area of a sign enclosed in frames or cabinets is determined by measuring the outer dimensions of the frame or cabinet surrounding the sign face.
(a) Sign area does not include foundation or supports.
(b) Only one side of a double-faced or V-shaped freestanding sign is counted in the calculation of total sign area. The height of a sign shall be measured from the natural grade to the top of the sign face or sign structure, whichever is higher.
(2) Sign height shall be measured according to the procedures set forth in § 157.192(B)(2).
(3) For signs on a base material and attached without a frame, such as wood board or polycarbonate panel, the dimensions of the base material are to be used in the measurement, unless it is clear that part of the base contains no sign-related display or decoration.
(4) For sign structures consisting of individual pieces attached to a building wall, sign area is determined by the smallest perimeter that can be drawn around all sign elements.
(5) For sign structures containing multiple modules oriented in the same direction, sign area is determined the smallest perimeter that can be drawn around all sign elements.
(6) For signs incorporated into awnings, the entire panel containing the sign is counted as the sign face, unless it is clear that part of the panel contains no sign-related display or decoration.
(Ord. 15-002, passed 2-24-15; Am. Ord. 2017-013, passed 10-10-17; Am. Ord. 2019-020, passed 11-12-19)
Signs shall be allowed on private property in accordance with the following table:
A = Allowed without a permit P = Permit required N = Not allowed | ZONING DISTRICT | |||||
SIGN TYPE | RE, R-15, R-10, R-6
R-6S | CBD | GBD | OI, LBD | IND | CMU |
A = Allowed without a permit P = Permit required N = Not allowed | ZONING DISTRICT | |||||
SIGN TYPE | RE, R-15, R-10, R-6
R-6S | CBD | GBD | OI, LBD | IND | CMU |
Freestanding Signs | ||||||
Principal | P1 | P | P | P | P | P |
Incidental | N | P | P | P | P | P |
Sidewalk | N | P | P | N | N | N |
Subdivision | P | N | N | N | N | P |
Buildings Signs | ||||||
Awning | N | P | P | N | P | P |
Canopy | N | P | P | P | P | P |
Identification | A | P | P | P | P | P |
Incidental | N | P | P | P | P | P |
Integral Roof | N | N | P | N | P | P |
Marquee | N | N | P | N | P | P |
Projecting | N | P | P | P | P | P |
Wall | P | P | P | P | P | P |
Window | N | A | A | A | A | A |
Copy and Illumination | ||||||
Changeable Copy | P | P | P | P | P | P |
Illumination, External | P | P | P | P | P | P |
Illumination, Internal | P1 | A | A | A | A | A |
(Ord. 15-002, passed 2-24-15; Am. Ord. 2015-022, passed 10-13-15; Am. Ord. 2016-002, passed 3-8- 16; Am. Ord. 2021-012, passed 6-22-21)
(A) Freestanding signs.
(1) Freestanding signs are allowed on lots with at least 50 feet of street frontage. Where permitted, freestanding signs may be installed in required buffers.
(2) All freestanding signs shall have a maximum width often feet.
(3) Freestanding signs must meet the following requirements:
(a) One freestanding sign per street frontage is allowed.
(b) In the OI and LBD zoning districts, principal signs shall have a maximum sign area of 20 square feet and a maximum height of six feet.
(c) In the CBD, GBD, IND and CMU zoning districts, principal signs shall have a maximum sign area of 40 square feet and a maximum height of six feet, except that multi-tenant developments on lots with 400 feet or more of street frontage may have one freestanding sign with a maximum sign area of 100 square feet and a maximum height of 15 feet. Sign area and height for lots with street frontage less than 400 feet shall be prorated.
(d) Pole signs shall only be internally illuminated.
(e) Monument signs may be internally or externally illuminated.
(4) Free-standing signs. Free-standing signs are permitted in all required yards, and front yard buffer areas (only).
(5) Incidental signs shall have a maximum sign area of three square feet and a maximum height of two and one-half feet. Incidental signs may only be internally illuminated.
(6) Sidewalk signs shall meet the following requirements:
(a) One sidewalk sign is allowed per business.
(b) A maximum height of four feet and a maximum width of two and one-half feet are allowed.
(c) The sign shall only be displayed when the business is open.
(d) Illumination of any type is prohibited.
(e) Signs must be placed on the sidewalk in front of the building, no further than 12 feet from the building.
(f) Signs shall be placed to allow a minimum passable space on the sidewalk of six feet, may not otherwise impede pedestrian movements, or create a conflict with any provision of the Americans with Disabilities Act.
(g) Signs shall be placed where they will not obstruct the swing radius of vehicle doors legally parked in the right-of-way.
(h) The sign shall not be attached to the ground or building, and must be constructed and weighted to prevent overturning and splaying.
(7) Subdivision signs shall meet the following requirements:
(a) One subdivision sign per entrance is allowed.
(b) A maximum sign area of 20 square feet and a maximum height of six feet are allowed.
(c) Subdivision signs shall only be externally illuminated.
(8) Freestanding principal signs for permitted institutional uses in residential zoning districts are permitted provided they meet the following criteria:
(a) Only one sign per street frontage is allowed;
(b) The maximum sign area is 20 square feet;
(c) The maximum sign height is six feet; and
(d) Signs may be internally or externally illuminated.
(B) Building signs.
(1) The total area of all building signs shall not exceed the following allowances:
(a) One square foot per linear foot of building frontage for a building set back less than 20 feet from the front property line.
(b) Two square feet per linear foot of building frontage for a building set back 20 feet or more from the front property line.
(c) The total area of all building signs shall not exceed 300 square feet per building.
(2) Buildings containing multiple building signs shall be required to submit a common signage plan meeting the requirements of § 157.108.
(3) Only the following types of building signs are allowed for permitted, nonresidential uses in all residential zoning districts: identification, incidental, and wall signs. A permit is required for such sign and will only be issued upon compliance with all requirements for each applicable specific sign type.
(4) Canopy, awning and marquee signs must conform to the following requirements:
(a) Only one canopy sign is allowed per street frontage.
(b) Only one marquee sign is allowed per street frontage.
(c) Signs on an awning, canopy or marquee shall not exceed 20% of the total area of the awning, canopy or marquee and shall be limited to the name of the business inside.
(d) Awnings, canopies and marquees shall only have signage on those surfaces that face a public street or which are oriented towards pedestrians on the sidewalk in front of the building. No part of a canopy sign shall extend above, below or beyond any portion of the canopy.
(e) Illumination.
1. Marquees shall only be internally illuminated.
2. Lights may be installed underneath awnings, canopies and marquees only if they are directed to point toward the ground, and are not used to illuminate the awning, canopy or marquee.
(f) A minimum clearance of eight feet is required between the bottom edge of an awning, canopy or marquee and the sidewalk, pavement or ground surface.
(5) Identification signs shall be limited to one per building, with a maximum sign area of two square feet and a maximum height of eight feet.
(6) Incidental signs attached to a building shall have a maximum sign area of three square feet.
(7) Integral roof signs shall conform to the following requirements:
(a) One integral roof sign is allowed per street frontage.
(b) The maximum sign area allowed for an integral roof sign is 20 square feet.
(c) An integral roof sign shall not extend more than four feet from the building.
(8) Projecting signs must conform to the following requirements:
(a) One projecting sign is allowed per street frontage.
(b) The maximum sign area allowed for a projecting sign is ten square feet.
(c) A minimum clearance of eight feet is required between the bottom of the sign and the sidewalk, pavement or ground surface.
(d) The maximum distance a projecting sign shall project from a building is four feet.
(e) Signs hanging over sidewalks shall not project from the building wall to an extent that they obstruct the view of pedestrians, bicyclists or motorists, or of street intersections, traffic signs, devices or signals.
(f) Projecting signs shall not be mounted higher than 12 feet.
(g) All projecting signs shall be mounted at right angles to the building wall.
(h) Projecting signs shall only be externally illuminated as specified in the illumination provisions of this section.
(9) Wall signs must conform to the following requirements:
(a) Wall signs may be externally or internally illuminated as specified in the illumination provisions of this section.
(b) No wall sign shall project more than 12 inches from the wall to which it is mounted, nor shall it extend beyond any point of the wall, a roof line, parapet wall, or mansard roof; except that signs shall not project beyond the face of the building a maximum of three inches in the Corridor Overlay District.
(c) If a building is located on a corner lot, a wall sign on the side of the building may not exceed 50% of the maximum size allowable in that zoning district.
(d) Permitted nonresidential uses in residential zoning districts (i.e. churches, schools, etc.) shall have a maximum of one wall sign, with a maximum sign area of 20 square feet and a maximum height of 15 feet.
(e) In the OI zoning district, a maximum of one wall sign, with a maximum sign area of 30 square feet and a maximum height of 15 feet, shall be allowed.
(f) The maximum sign area allowed in the CBD, GBD, LBD, IND, and CMU zoning districts is as follows:
1. One square foot per linear foot of building frontage for a building set back less than 20 feet from the front property line.
2. Two square foot per linear foot of building frontage for a building set back 20 feet or more from the front property line.
3. No individual sign shall exceed 100 square feet unless the building is set back at least 100 feet from the front property line.
(g) The maximum sign height allowed in the CBD, GBD, LBD, IND and CMU zoning districts is as follows:
1. In the CBD and LBD zoning districts, the maximum sign height is 20 feet.
2. In the GBD, CMU and IND zoning districts, wall signs may extend to the height of the building.
(10) The size of any window sign or cumulative size of all window signs shall not exceed 30% of the size of the individual window on which they are located. This requirement shall apply to windows fronting any public street. The total accumulated size of window signs on all windows of a building shall not exceed 300 square feet.
(11) Illuminated neon signs located within four feet of a window and that are plainly visible from any public street shall not exceed a maximum sign area of two square feet and no more than two illuminated neon signs may be displayed per street frontage. No illuminated neon sign may be displayed outside of a building.
(C) Changeable copy signs.
(1) Changeable copy shall be permitted only on permanent principal and institutional freestanding signs, marquee signs, canopy signs and wall signs, and shall comply with all of the regulations of such signs as applicable, and as outlined in this section.
(2) The portion of a sign that includes changeable copy letters shall not exceed 50% of the total area of the sign.
(3) Changeable copy by electronic or automated means is allowed; however copy cannot be changed more than three times per day.
(Ord. 15-002, passed 2-24-15; Am. Ord. 2015-022, passed 10-13-15; Am. Ord. 2016-002, passed 3-8- 16; Am. Ord. 2017-013, passed 10-10-17; Am. Ord. 2019-020, passed 11-12-19)
(A) A common signage plan shall be required to issue a permit involving any of the following:
(1) Two or more contiguous lots or parcels under the same ownership developed as a coordinated site;
(2) A single lot or parcel with more than one principal use or building (not including accessory structures) or qualifying on the basis of street frontage for more than one freestanding sign; and
(3) A Planned Development District (PDD).
(B) The plan shall contain all information required for sign permits as stated in § 157.114, and shall specify standards for consistency among all signs on the lot or parcel affected by the plan with regard to:
(1) Lettering or graphic style;
(2) Lighting;
(3) Location of each sign on the building;
(4) Materials; and
(5) Sign proportions.
(C) For all lots or development tracts in all zoning districts containing multiple uses or buildings, the common signage plan shall limit the number of freestanding signs to a total of one for each street in which the lots included in the plan have frontage, and shall provide for shared or common usage of such signs.
(D) Once approved by the Zoning Administrator, the common signage plan shall become binding on all businesses and uses occupying the affected lots, but may be amended by filing a new or revised plan that complies with all the requirements of this subchapter.
(E) If any new or revised common signage plan is filed for a property on which existing signs are located, it shall include a schedule for bringing into conformance, within 18 months, all signs not conforming to the proposed amended plan or the requirements of this subchapter in effect on the date of submission.
(Ord. 15-002, passed 2-24-15)
The following conditions shall apply to temporary signs.
(A) Temporary signs shall not exceed three square feet. Temporary signs used for advertising businesses shall only be allowed in commercial zoning districts.
(B) Temporary signs shall be removed or replaced every 30 days, unless otherwise stated in this section.
(C) Temporary signs are prohibited in the public right-of-way or on any public property, utility poles, or street signs.
(D) Temporary signs shall be limited to one per street frontage.
(E) Temporary signs shall not be illuminated.
(F) Reserved.
(G) Banners are allowed with a permit only in the CBD, GBD, LBD, OI, IND and CMU zoning districts.
(1) Banners must be attached to a building and cannot exceed 32 square feet.
(2) Only one banner shall be allowed per building.
(3) Banners are allowed only if the combined square footage of the banner and all other signs does not exceed the maximum square footage allowed for building signs.
(Ord. 15-002, passed 2-24-15; Am. Ord. 2015-022, passed 10-13-15; Am. Ord. 2019-020, passed 11- 12-19; Am. Ord. 2020-023, passed 10-27-20)
(A) No permit shall be required to display a flag.
(B) Each business shall be allowed a maximum of three flags, with each flag being a maximum of five feet by eight feet.
(C) All flags must be displayed from a permanent mounting on the building or on a permanent flag pole.
(D) Only one flag can advertise the business.
(E) The area of the advertising flag shall not exceed the maximum sign area allowed for building signs.
(F) The flag of the United States shall be flown in accordance with the United States Flag Code, and the flag of the State of South Carolina shall be flown in accordance with protocols established by the State of South Carolina.
(Ord. 15-002, passed 2-24-15; Am. Ord. 2019-020, passed 11-12-19)